688 related articles for article (PubMed ID: 20088013)
1. First trans-axillary implantation of Edwards Sapien valve to treat an incompetent aortic bioprosthesis.
Sharp AS; Michev I; Colombo A
Catheter Cardiovasc Interv; 2010 Mar; 75(4):507-10. PubMed ID: 20088013
[TBL] [Abstract][Full Text] [Related]
2. First-in-man case report of the use of an Edwards-Sapien valve to treat a regurgitant CoreValve aortic valve prosthesis.
Taramasso M; Sharp AS; Maisano F
Catheter Cardiovasc Interv; 2010 Jan; 75(1):51-5. PubMed ID: 19642192
[TBL] [Abstract][Full Text] [Related]
3. Transcatheter valve-in-valve implantation for the treatment of stentless aortic valve dysfunction.
Rodés-Cabau J; Dumont E; Doyle D; Lemieux J
J Thorac Cardiovasc Surg; 2010 Jul; 140(1):246-8. PubMed ID: 19783014
[No Abstract] [Full Text] [Related]
4. Successful reposition and treatment of severe aortic paraprosthetic regurgitation after percutaneous implantation of a self-expandable biological valve.
Frerker C; Bergmann M; Schewel D; Busse C; Jensen F; Schmoeckel M; Schneider C; Kuck KH; Schaefer U
J Cardiovasc Med (Hagerstown); 2012 May; 13(5):346-50. PubMed ID: 20479655
[No Abstract] [Full Text] [Related]
5. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis.
Attia R; Bapat V
Catheter Cardiovasc Interv; 2013 Aug; 82(2):324-7. PubMed ID: 22120953
[TBL] [Abstract][Full Text] [Related]
6. Aortic valve in valve insertion: a note of caution and a case for possible optimism.
Dean LS
Catheter Cardiovasc Interv; 2010 Dec; 76(7):1007-8. PubMed ID: 21108376
[No Abstract] [Full Text] [Related]
7. Difficulties with horizontal aortic root in transcatheter aortic valve implantation.
Chan PH; Alegria-Barrero E; Di Mario C
Catheter Cardiovasc Interv; 2013 Mar; 81(4):630-5. PubMed ID: 22431290
[TBL] [Abstract][Full Text] [Related]
8. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation.
Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Sieswerda G; Budde R; van der Linden M; Juthier F; Banfi C; Hurt C; Samim M; Hillaert M; van Herwerden L; Bertrand ME; Doevendans PA; Van Belle E
J Thorac Cardiovasc Surg; 2013 Feb; 145(2):398-405. PubMed ID: 22377664
[TBL] [Abstract][Full Text] [Related]
9. Successful transfemoral Edwards SAPIEN 3 valve in valve implantation in a patient with a degenerated aortic bioprosthesis associated with severe paravalvular aortic regurgitation.
Bijuklic K; Hansen L; Witt J; Schofer J
Clin Res Cardiol; 2015 Jan; 104(1):92-3. PubMed ID: 25227426
[No Abstract] [Full Text] [Related]
10. Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses CoreValve for failed bioprosthetic aortic valve replacements.
Khawaja MZ; Haworth P; Ghuran A; Lee L; de Belder A; Hutchinson N; Trivedi U; Laborde JC; Hildick-Smith D
J Am Coll Cardiol; 2010 Jan; 55(2):97-101. PubMed ID: 20117377
[TBL] [Abstract][Full Text] [Related]
11. Severe intraprosthetic regurgitation and valve embolization after transcatheter aortic valve implantation.
Ben-Dor I; Satler LF; Pichard AD; Waksman R
Catheter Cardiovasc Interv; 2013 Feb; 81(2):392-6. PubMed ID: 22566389
[TBL] [Abstract][Full Text] [Related]
12. First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve.
Binder RK; Wood D; Webb JG; Cheung A
Catheter Cardiovasc Interv; 2013 Dec; 82(7):E929-31. PubMed ID: 22821872
[TBL] [Abstract][Full Text] [Related]
13. Early experience of implantation of the new CoreValve(®) Evolut(™) in degenerated bioprosthetic aortic valves.
Fairley SL; Jeganathan R; Manoharan G; Spence MS
Catheter Cardiovasc Interv; 2014 Feb; 83(3):485-92. PubMed ID: 23857751
[TBL] [Abstract][Full Text] [Related]
14. Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results.
Bapat V; Attia R; Redwood S; Hancock J; Wilson K; Young C; Thomas M
J Thorac Cardiovasc Surg; 2012 Dec; 144(6):1372-9; discussion 1379-80. PubMed ID: 23140962
[TBL] [Abstract][Full Text] [Related]
15. Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValveTM prosthesis due to a too-low implantation, using transcatheter repositioning.
Zahn R; Schiele R; Kilkowski C; Klein B; Zeymer U; Werling C; Lehmann A; Gerckens U; Saggau W
J Heart Valve Dis; 2011 Jan; 20(1):64-9. PubMed ID: 21404899
[TBL] [Abstract][Full Text] [Related]
16. Treatment of a failing St. Jude Medical Trifecta by Medtronic Corevalve Evolut valve-in-valve implantation.
Haussig S; Schuler G; Linke A
JACC Cardiovasc Interv; 2014 Jul; 7(7):e81-2. PubMed ID: 24954575
[No Abstract] [Full Text] [Related]
17. Procedural and clinical outcomes of the valve-in-valve technique for severe aortic insufficiency after balloon-expandable transcatheter aortic valve replacement.
Giri J; Bortnick AE; Wallen T; Walsh E; Bannan A; Desai N; Szeto WY; Bavaria J; Herrmann HC
Catheter Cardiovasc Interv; 2012 Jul; 80(1):139-47. PubMed ID: 22419611
[TBL] [Abstract][Full Text] [Related]
18. Transaortic transcatheter aortic valve implantation within a previous bioprosthetic aortic valve replacement.
Cockburn J; Trivedi U; Hildick-Smith D
Catheter Cardiovasc Interv; 2011 Sep; 78(3):479-84. PubMed ID: 21793174
[TBL] [Abstract][Full Text] [Related]
19. Transcatheter aortic valve implantation for severe aortic regurgitation in a stentless bioprosthetic valve with the Core Valve revalving system-technical tips and role of the Accutrak system.
Sarkar K; Ussia GP; Tamburino C
Catheter Cardiovasc Interv; 2011 Sep; 78(3):485-90. PubMed ID: 21557449
[TBL] [Abstract][Full Text] [Related]
20. Transseptal approach for the management of paravalvular regurgitation after transcatheter aortic valve replacement.
Martinez CA; O'Neill B; Singh V; O'Neill WW
Catheter Cardiovasc Interv; 2013 Oct; 82(4):E587-91. PubMed ID: 23008182
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]