These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 20091924)

  • 41. The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.
    Baleani M; Bialoblocka-Juszczyk E; Engels GE; Viceconti M
    J Bone Joint Surg Br; 2010 Mar; 92(3):454-60. PubMed ID: 20190321
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Bond strength analysis of the bone cement- stem interface of hip arthroplasties.
    Zhang LF; Ge SR; Liu HT; Guo KJ; Han SY; Qi JY
    Asian Pac J Trop Med; 2014 Feb; 7(2):153-9. PubMed ID: 24461531
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Does vacuum mixing affect diameter shrinkage of a PMMA cement mantle during in vitro cemented acetabulum implantation?
    Boote AT; Bigsby RJ; Deehan DJ; Rankin KS; Swailes DC; Hyde PJ
    Proc Inst Mech Eng H; 2021 Feb; 235(2):133-140. PubMed ID: 33054541
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effects of stem length on mechanics of the femoral hip component after cemented revision.
    Mann KA; Ayers DC; Damron TA
    J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Modification of Mechanical Properties, Polymerization Temperature, and Handling Time of Polymethylmethacrylate Cement for Enhancing Applicability in Vertebroplasty.
    Tai CL; Lai PL; Lin WD; Tsai TT; Lee YC; Liu MY; Chen LH
    Biomed Res Int; 2016; 2016():7901562. PubMed ID: 27812530
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The mechanical properties of recovered PMMA bone cement: a preliminary study.
    Chaplin RP; Lee AJ; Hooper RM; Clarke M
    J Mater Sci Mater Med; 2006 Dec; 17(12):1433-48. PubMed ID: 17143776
    [TBL] [Abstract][Full Text] [Related]  

  • 47. In vivo behavior of acrylic bone cement in total hip arthroplasty.
    Ries MD; Young E; Al-Marashi L; Goldstein P; Hetherington A; Petrie T; Pruitt L
    Biomaterials; 2006 Jan; 27(2):256-61. PubMed ID: 16039712
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.
    Koh BT; Tan JH; Ramruttun AK; Wang W
    J Orthop Surg Res; 2015 Nov; 10():178. PubMed ID: 26577581
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Equivalent hip stem fixation by Hi-Fatigue G and Palacos R + G bone cement: a randomized radiostereometric controlled trial of 52 patients with 2 years' follow-up.
    Jørgensen PB; Lamm M; Søballe K; Stilling M
    Acta Orthop; 2019 Jun; 90(3):237-242. PubMed ID: 30931663
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Do we need to vacuum mix or centrifuge cement?
    Wixson RL
    Clin Orthop Relat Res; 1992 Dec; (285):84-90. PubMed ID: 1446459
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Relative roles of cement molecular weight and mixing method on the fatigue performance of acrylic bone cement: Simplex P versus Osteopal.
    Lewis G
    J Biomed Mater Res; 2000; 53(1):119-30. PubMed ID: 10634961
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Thermal isotherms in PMMA and cell necrosis during total hip arthroplasty.
    Gundapaneni D; Goswami T
    J Appl Biomater Funct Mater; 2014 Dec; 12(3):193-202. PubMed ID: 24756782
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Revision of cemented fixation and cement-bone interface strength.
    Rosenstein A; MacDonald W; Iliadis A; McLardy-Smith P
    Proc Inst Mech Eng H; 1992; 206(1):47-9. PubMed ID: 1418194
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Stem-cement porosity may explain early loosening of cemented femoral hip components: experimental-computational in vitro study.
    Mann KA; Damron LA; Miller MA; Race A; Clarke MT; Cleary RJ
    J Orthop Res; 2007 Mar; 25(3):340-50. PubMed ID: 17149748
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Radiographic and histologic analysis of cemented double tapered femoral stems.
    Brumby SA; Howie DW; Pearcy MJ; Wang AW; Nawana NS
    Clin Orthop Relat Res; 1998 Oct; (355):229-37. PubMed ID: 9917608
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Reinforcement of PMMA bone cement with a continuous wire coil--a 3D finite element study.
    Frigstad JR; Park JB
    Biomed Mater Eng; 1996; 6(6):429-39. PubMed ID: 9138653
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Fatigue debonding of the roughened stem-cement interface: effects of surface roughness and stem heating conditions.
    Damron LA; Kim DG; Mann KA
    J Biomed Mater Res B Appl Biomater; 2006 Jul; 78(1):181-8. PubMed ID: 16292769
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.
    Bader R; Steinhauser E; Holzwarth U; Schmitt M; Mittelmeier W
    Proc Inst Mech Eng H; 2004; 218(4):223-30. PubMed ID: 15376724
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Cement debonding process of total hip arthroplasty stems.
    Verdonschot N; Huiskes R
    Clin Orthop Relat Res; 1997 Mar; (336):297-307. PubMed ID: 9060516
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.