These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 20096437)

  • 21. Fundamental characteristics of bubbles and ramifications for the flotation process.
    Dockko S; Han MY
    Water Sci Technol; 2004; 50(12):207-14. PubMed ID: 15686023
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Particle visualisation--a tool for determination of rise velocities.
    Ljunggren M; Jönsson L; la Cour Jansen J
    Water Sci Technol; 2004; 50(12):229-36. PubMed ID: 15686026
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High-rate dissolved air flotation for water treatment.
    Reall MA; Marchetto M
    Water Sci Technol; 2001; 43(8):43-9. PubMed ID: 11394278
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Coagulation, flocculation, dissolved air flotation and filtration in the removal of Giardia spp. and Cryptosporidium spp. from water supply.
    Andreoli FC; Sabogal-Paz LP
    Environ Technol; 2019 Feb; 40(5):654-663. PubMed ID: 29090610
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pretreatment of bakery wastewater by coagulation-flocculation and dissolved air flotation.
    Liu JC; Lien CS
    Water Sci Technol; 2001; 43(8):131-7. PubMed ID: 11394265
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Characterization of micro-bubble size distribution and flow configuration in DAF contact zone by a non-intrusive image analysis system and tracer tests.
    Moruzzi RB; Reali MA
    Water Sci Technol; 2010; 61(1):253-62. PubMed ID: 20057112
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Removal of Cryptosporidium and Giardia in drinking water treatment in a Tuscan area].
    Sacco C; Bianchi M; Lorini C; Burrini D; Berchielli S; Lanciotti E
    Ann Ig; 2006; 18(2):117-26. PubMed ID: 16649509
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of inclined plate sedimentation and dissolved air flotation for the minimisation of subsequent nitrogenous disinfection by-product formation.
    Chu WH; Gao NY; Templeton MR; Yin DQ
    Chemosphere; 2011 Apr; 83(5):647-51. PubMed ID: 21420143
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Aerobic bacterial spores as process indicators for protozoa cysts in water treatment plants.
    Galofré B; Israel S; Dellundé J; Ribas F
    Water Sci Technol; 2004; 50(1):165-72. PubMed ID: 15318504
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Integration of dissolved gas flotation and nanofiltration for M. aeruginosa and associated microcystins removal.
    Teixeira MR; Rosa MJ
    Water Res; 2006 Nov; 40(19):3612-20. PubMed ID: 16860837
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Phosphorus removal with membrane filtration for surface water treatment.
    Dietze A; Gnirss R; Wiesmann U
    Water Sci Technol; 2002; 46(4-5):257-64. PubMed ID: 12361018
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of pathogen concentrations on removal of Cryptosporidium and Giardia by conventional drinking water treatment.
    Assavasilavasukul P; Lau BL; Harrington GW; Hoffman RM; Borchardt MA
    Water Res; 2008 May; 42(10-11):2678-90. PubMed ID: 18313095
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Seasonal influence of waste stabilisation pond effluent on DAF/F (dissolved air flotation/filtration) process operation.
    Buisine F; Oemcke D
    Water Sci Technol; 2003; 48(2):357-64. PubMed ID: 14510231
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimizing dissolved air flotation design and saturation.
    Féris LA; Gallina CW; Rodrigues RT; Rubio J
    Water Sci Technol; 2001; 43(8):145-52. PubMed ID: 11394267
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Measuring resistant forms of two pathogenic protozoa (Giardia spp and Cryptosporidium spp) in two aquatic biotopes in Yaoundé (Cameroon)].
    Gideon AA; Njiné T; Nola M; Menbohan SF; Ndayo MW
    Sante; 2007; 17(3):167-72. PubMed ID: 18180218
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of floc and bubble size on the efficiency of the dissolved air flotation (DAF) process.
    Han M; Kim TI; Kim J
    Water Sci Technol; 2007; 56(10):109-15. PubMed ID: 18048983
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A decade of large scale experience in dissolved air flotation.
    Kempeneers S; Van Menxel F; Gille L
    Water Sci Technol; 2001; 43(8):27-34. PubMed ID: 11394276
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monitoring and evaluation of removal of pathogens at municipal wastewater treatment plants.
    Fu CY; Xie X; Huang JJ; Zhang T; Wu QY; Chen JN; Hu HY
    Water Sci Technol; 2010; 61(6):1589-99. PubMed ID: 20351439
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Simultaneous removal of cadmium and turbidity in contaminated soil-washing water by DAF and electroflotation.
    Park J; Jung Y; Han M; Lee S
    Water Sci Technol; 2002; 46(11-12):225-30. PubMed ID: 12523758
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Integrated pretreatment with capacitive deionization for reverse osmosis reject recovery from water reclamation plant.
    Lee LY; Ng HY; Ong SL; Tao G; Kekre K; Viswanath B; Lay W; Seah H
    Water Res; 2009 Oct; 43(18):4769-77. PubMed ID: 19700181
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.