These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 2009979)

  • 21. Significance of the early postoperative duplex result in infrainguinal vein bypass surveillance.
    Mofidi R; Kelman J; Berry O; Bennett S; Murie JA; Dawson AR
    Eur J Vasc Endovasc Surg; 2007 Sep; 34(3):327-32. PubMed ID: 17521931
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Balloon dilatation versus surgical revision of infra-inguinal autogenous vein graft stenoses: long-term follow-up.
    Perler BA; Osterman FA; Mitchell SE; Burdick JF; Williams GM
    J Cardiovasc Surg (Torino); 1990; 31(5):656-61. PubMed ID: 2229167
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Surgical treatment of threatened reversed infrainguinal vein grafts.
    Nehler MR; Moneta GL; Yeager RA; Edwards JM; Taylor LM; Porter JM
    J Vasc Surg; 1994 Oct; 20(4):558-63; discussion 563-5. PubMed ID: 7933257
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intraoperative duplex monitoring of infrainguinal vein bypass procedures.
    Johnson BL; Bandyk DF; Back MR; Avino AJ; Roth SM
    J Vasc Surg; 2000 Apr; 31(4):678-90. PubMed ID: 10753275
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Graft type for femoro-popliteal bypass surgery.
    Mamode N; Scott RN
    Cochrane Database Syst Rev; 2000; (2):CD001487. PubMed ID: 10796649
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hemodynamic impact of vein graft stenoses and their prediction in the vascular laboratory.
    Belkin M; Schwartz LB; Donaldson MC; Mannick JA; Whittemore AD
    J Vasc Surg; 1997 Jun; 25(6):1016-21; discussion 1022. PubMed ID: 9201162
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cutting balloon angioplasty versus standard balloon angioplasty for failing infra-inguinal vein grafts: comparative study of short- and mid-term primary patency rates.
    Vikram R; Ross RA; Bhat R; Griffiths GD; Stonebridge PA; Houston JG; Chakraverty S
    Cardiovasc Intervent Radiol; 2007; 30(4):607-10. PubMed ID: 17393055
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of duplex ultrasound with digital subtraction angiography in the assessment of infra-inguinal autologous vein bypass grafts.
    Griffin NM; Wright IA; Buckenham TM
    ANZ J Surg; 2006 Nov; 76(11):966-9. PubMed ID: 17054543
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cost efficacy of duplex surveillance and prophylactic angioplasty of arteriovenous ePTFE grafts.
    Lumsden AB; MacDonald MJ; Kikeri D; Cotsonis GA; Harker LA; Martin LG
    Ann Vasc Surg; 1998 Mar; 12(2):138-42. PubMed ID: 9514231
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The value of duplex scanning in surveillance of infra-inguinal vein and synthetic grafts.
    Tong Y; Royle J
    Aust N Z J Surg; 1994 Oct; 64(10):684-7. PubMed ID: 7945065
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Intraoperative superficial femoral artery balloon angioplasty and popliteal to distal bypass graft: an option for combined open and endovascular treatment of diabetic gangrene.
    Schneider PA; Caps MT; Ogawa DY; Hayman ES
    J Vasc Surg; 2001 May; 33(5):955-62. PubMed ID: 11331834
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Midterm results of autologous saphenous vein and ePTFE pre-cuffed bypass surgery in peripheral arterial occlusive disease.
    Donker JM; Ho GH; Te Slaa A; de Groot HG; van der Waal JC; Veen EJ; van der Laan L
    Vasc Endovascular Surg; 2011 Oct; 45(7):598-603. PubMed ID: 21757494
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: a five-year experience.
    Idu MM; Blankenstein JD; de Gier P; Truyen E; Buth J
    J Vasc Surg; 1993 Jan; 17(1):42-52; discussion 52-3. PubMed ID: 8421341
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Vein graft surveillance improves patency in femoro-popliteal bypass.
    Moody P; Gould DA; Harris PL
    Eur J Vasc Surg; 1990 Apr; 4(2):117-21. PubMed ID: 2140986
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Factors determining late patency of aortobifemoral bypass graft].
    Davidović LB; Lotina SI; Kostić DM; Cinara II; Cvetković SD; Stojanov PL; Velimirović DB; Marković MM; Pejkić SA; Vukotić AM
    Srp Arh Celok Lek; 1997; 125(1-2):24-35. PubMed ID: 17974352
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Contribution of routine intraoperative completion arteriography to early infrainguinal bypass patency.
    Mills JL; Fujitani RM; Taylor SM
    Am J Surg; 1992 Nov; 164(5):506-10; discussion 510-1. PubMed ID: 1443378
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Four-year randomized prospective comparison of percutaneous ePTFE/nitinol self-expanding stent graft versus prosthetic femoral-popliteal bypass in the treatment of superficial femoral artery occlusive disease.
    McQuade K; Gable D; Pearl G; Theune B; Black S
    J Vasc Surg; 2010 Sep; 52(3):584-90; discussion 590-1, 591.e1-591.e7. PubMed ID: 20598480
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Serial duplex scans elucidate the evolving hemodynamics of distal arteriovenous fistulas.
    Alexander JB; Spence RK; Camishion RC
    Ann Vasc Surg; 1991 Mar; 5(2):176-81. PubMed ID: 2015189
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Relationship between the diameter of the vein graft and postoperative ankle brachial pressure index following femoro-popliteal bypass.
    Matsushita M; Ikezawa T; Banno H
    Int Angiol; 2008 Aug; 27(4):329-32. PubMed ID: 18677296
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Economising vein-graft surveillance programs.
    Idu MM; Buth J; Cuypers P; Hop WC; van de Pavoordt ED; Tordoir JM
    Eur J Vasc Endovasc Surg; 1998 May; 15(5):432-8. PubMed ID: 9633500
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.