These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
158 related articles for article (PubMed ID: 20100697)
1. Achieving an adequate minute volume through a 2 mm transtracheal catheter in simulated upper airway obstruction using a modified industrial ejector. Hamaekers AE; Götz T; Borg PA; Enk D Br J Anaesth; 2010 Mar; 104(3):382-6. PubMed ID: 20100697 [TBL] [Abstract][Full Text] [Related]
2. Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance. Hamaekers AE; Borg PA; Götz T; Enk D Br J Anaesth; 2011 Mar; 106(3):403-9. PubMed ID: 21177698 [TBL] [Abstract][Full Text] [Related]
3. A bench study of ventilation via two self-assembled jet devices and the Oxygen Flow Modulator in simulated upper airway obstruction. Hamaekers AE; Borg PA; Enk D Anaesthesia; 2009 Dec; 64(12):1353-8. PubMed ID: 19821809 [TBL] [Abstract][Full Text] [Related]
4. Transtracheal ventilation with a novel ejector-based device (Ventrain) in open, partly obstructed, or totally closed upper airways in pigs. Paxian M; Preussler NP; Reinz T; Schlueter A; Gottschall R Br J Anaesth; 2015 Aug; 115(2):308-16. PubMed ID: 26115955 [TBL] [Abstract][Full Text] [Related]
5. Percutaneous transtracheal ventilation in an obstructed airway model in post-apnoeic sheep. Berry M; Tzeng Y; Marsland C Br J Anaesth; 2014 Dec; 113(6):1039-45. PubMed ID: 24980421 [TBL] [Abstract][Full Text] [Related]
6. Ventrain: an ejector ventilator for emergency use. Hamaekers AE; Borg PA; Enk D Br J Anaesth; 2012 Jun; 108(6):1017-21. PubMed ID: 22436319 [TBL] [Abstract][Full Text] [Related]
7. Jet or intensive care unit ventilator during simulated percutaneous transtracheal ventilation: a lung model study. Liu YH; Wang AL; Marchese AD; Kacmarek RM; Jiang Y Br J Anaesth; 2013 Mar; 110(3):456-62. PubMed ID: 23171722 [TBL] [Abstract][Full Text] [Related]
9. Effects of graded upper-airway obstruction on pulmonary mechanics during transtracheal jet ventilation in dogs. Carl ML; Rhee KJ; Schelegle ES; Green JF Ann Emerg Med; 1994 Dec; 24(6):1137-43. PubMed ID: 7978596 [TBL] [Abstract][Full Text] [Related]
10. Compensating Artificial Airway Resistance via Active Expiration Assistance. Wirth S; Seywert L; Spaeth J; Schumann S Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619 [TBL] [Abstract][Full Text] [Related]
11. Transtracheal jet ventilation in the 'can't intubate can't oxygenate' emergency: a systematic review. Duggan LV; Ballantyne Scott B; Law JA; Morris IR; Murphy MF; Griesdale DE Br J Anaesth; 2016 Sep; 117 Suppl 1():i28-i38. PubMed ID: 27566790 [TBL] [Abstract][Full Text] [Related]
12. Tidal volume and airway pressure under percutaneous transtracheal ventilation without a jet ventilator: comparison of high-flow oxygen ventilation and manual ventilation in complete and incomplete upper airway obstruction models. Sasano N; Tanaka A; Muramatsu A; Fujita Y; Ito S; Sasano H; Sobue K J Anesth; 2014 Jun; 28(3):341-6. PubMed ID: 24212332 [TBL] [Abstract][Full Text] [Related]
13. [Monitoring tidal volumes when using the Ventrain® emergency ventilator]. Schmidt AR; Ruetzler K; Haas T; Schmitz A; Weiss M Anaesthesist; 2016 Jul; 65(7):514-20. PubMed ID: 27245923 [TBL] [Abstract][Full Text] [Related]
14. High frequency jet ventilation through the laryngeal mask airway in a critically obstructed airway. Williams A; Patel A; Ferguson C Anaesthesia; 2008 Dec; 63(12):1369-71. PubMed ID: 18803629 [TBL] [Abstract][Full Text] [Related]
15. Rescue ventilation through a small-bore transtracheal cannula in severe hypoxic pigs using expiratory ventilation assistance. Hamaekers AE; van der Beek T; Theunissen M; Enk D Anesth Analg; 2015 Apr; 120(4):890-4. PubMed ID: 25565319 [TBL] [Abstract][Full Text] [Related]
16. A comparison in a lung model of low- and high-flow regulators for transtracheal jet ventilation. Gaughan SD; Ozaki GT; Benumof JL Anesthesiology; 1992 Jul; 77(1):189-99. PubMed ID: 1609992 [TBL] [Abstract][Full Text] [Related]
17. Percutaneous Transtracheal Jet Ventilation with Various Upper Airway Obstruction. Doi T; Miyashita T; Furuya R; Sato H; Takaki S; Goto T Biomed Res Int; 2015; 2015():454807. PubMed ID: 26161402 [TBL] [Abstract][Full Text] [Related]
18. Ventilation of a model lung using various cricothyrotomy devices. Craven RM; Vanner RG Anaesthesia; 2004 Jun; 59(6):595-9. PubMed ID: 15144301 [TBL] [Abstract][Full Text] [Related]
19. Effects of helium on high frequency jet ventilation in model of airway stenosis. Buczkowski PW; Fombon FN; Russell WC; Thompson JP Br J Anaesth; 2005 Nov; 95(5):701-5. PubMed ID: 16143576 [TBL] [Abstract][Full Text] [Related]
20. Jet ventilation in upper airway obstruction: description and model lung testing of a new jetting device. Garry B; Woo P; Perrault DF; Shapshay SM; Wurm WH Anesth Analg; 1998 Oct; 87(4):915-20. PubMed ID: 9768794 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]