These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 20104155)

  • 1. Correction of bone angular deformities: experimental analysis of staples versus 8-plate.
    Goyeneche RA; Primomo CE; Lambert N; Miscione H
    J Pediatr Orthop; 2009; 29(7):736-40. PubMed ID: 20104155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Temporary hemiepiphysiodesis with blount staples and eight-plates in pigs.
    Kanellopoulos AD; Mavrogenis AF; Dovris D; Vlasis K; Burghart R; Soucacos PN; Papagelopoulos PJ; Herzenberg JE
    Orthopedics; 2011 Apr; 34(4):. PubMed ID: 21469635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Eight-Plate Guided Growth Treatment for Angular Deformities and Length Discrepancies of the Lower Limbs in Children. Our First Experience].
    Jochymek J; Peterková T
    Acta Chir Orthop Traumatol Cech; 2015; 82(6):424-9. PubMed ID: 26787183
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rate of correction after asymmetrical physeal suppression in valgus deformity: analysis using a linear mixed model application.
    Sung KH; Ahn S; Chung CY; Lee KM; Kim TW; Han HS; Kim DH; Choi IH; Cho TJ; Yoo WJ; Park MS
    J Pediatr Orthop; 2012 Dec; 32(8):805-14. PubMed ID: 23147624
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Physeal stapling versus 8-plate hemiepiphysiodesis for guided correction of angular deformity about the knee.
    Wiemann JM; Tryon C; Szalay EA
    J Pediatr Orthop; 2009; 29(5):481-5. PubMed ID: 19568021
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Guided growth: the importance of a single tether. An experimental study.
    Sanpera I; Raluy-Collado D; Frontera-Juan G; Tejada-Gavela S; Ramos-Asensio R
    J Pediatr Orthop; 2012 Dec; 32(8):815-20. PubMed ID: 23147625
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemiepiphysiodesis for correction of angular deformity in pediatric amputees.
    Gyr BM; Colmer HG; Morel MM; Ferski GJ
    J Pediatr Orthop; 2013; 33(7):737-42. PubMed ID: 23812150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemiepiphyseal stapling for angular deformity correction around the knee joint in children with multiple epiphyseal dysplasia.
    Cho TJ; Choi IH; Chung CY; Yoo WJ; Park MS; Lee DY
    J Pediatr Orthop; 2009; 29(1):52-6. PubMed ID: 19098647
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Epiphyseal stapling for angular deformity at the knee.
    Zuege RC; Kempken TG; Blount WP
    J Bone Joint Surg Am; 1979 Apr; 61(3):320-9. PubMed ID: 429399
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemiepiphyseal arrest in a porcine model.
    Burghardt RD; Kanellopoulos AD; Herzenberg JE
    J Pediatr Orthop; 2011 Jun; 31(4):e25-9. PubMed ID: 21572268
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Correction of angular deformity of the knee in growing children by temporary hemiepiphyseodesis using the eight-plate].
    Niethard M; Deja M; Rogalski M
    Z Orthop Unfall; 2010 Mar; 148(2):215-21. PubMed ID: 20135618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hemiepiphyseal stapling for knee deformities in children younger than 10 years: a preliminary report.
    Mielke CH; Stevens PM
    J Pediatr Orthop; 1996; 16(4):423-9. PubMed ID: 8784692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Torsional Growth Modulation of Long Bones by Oblique Plating in a Rabbit Model.
    Lazarus DE; Farnsworth CL; Jeffords ME; Marino N; Hallare J; Edmonds EW
    J Pediatr Orthop; 2018 Feb; 38(2):e97-e103. PubMed ID: 29189535
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of femoral physeal activity after transitory hemiepiphysiodesis using screws and nonabsorbable filament.
    Martínez GS; Baar AZ; Ibañez AL; Vergara PG; Carmona MC; Drago SP
    J Pediatr Orthop; 2014 Mar; 34(2):208-12. PubMed ID: 24096443
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Results of screw epiphysiodesis for the treatment of limb length discrepancy and angular deformity.
    Khoury JG; Tavares JO; McConnell S; Zeiders G; Sanders JO
    J Pediatr Orthop; 2007 Sep; 27(6):623-8. PubMed ID: 17717460
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Temporary hemiepiphysiodesis with the eight-Plate for angular deformities: mid-term results.
    Burghardt RD; Herzenberg JE
    J Orthop Sci; 2010 Sep; 15(5):699-704. PubMed ID: 20953936
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Design and experimental study of an epiphyseal slide-traction plate].
    Lian KJ; Hong JY; Ji YQ; Ding ZQ; Lin B; Zhai WL; Chen CQ
    Zhongguo Gu Shang; 2008 Oct; 21(10):752-6. PubMed ID: 19105370
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Permanent and temporary epiphysiodesis: an experimental study in a rabbit model.
    Kömür B; Coşkun M; Kömür AA; Oral A
    Acta Orthop Traumatol Turc; 2013; 47(1):48-54. PubMed ID: 23552720
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Temporary Hemiepiphysiodesis in the Correction of Axial Deformities for Genua Valga: Retrospective Assessment and Comparison of Outcomes Achieved with the Use of Eight-Figure Plates and Blount Staples].
    Turek J; Homolová N; Urbášek K; Seehofnerová A; Plánka L; Marek O
    Acta Chir Orthop Traumatol Cech; 2022; 89(3):193-198. PubMed ID: 35815485
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Guiding femoral rotational growth in an animal model.
    Arami A; Bar-On E; Herman A; Velkes S; Heller S
    J Bone Joint Surg Am; 2013 Nov; 95(22):2022-7. PubMed ID: 24257660
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.