These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 20109365)

  • 41. [In vivo experiment of porous bioactive bone cement modified by bioglass and chitosan].
    Li Y; Lei W; Wang Z; Zhang Y; Niu E; Yu L; Wu J; Zang Y; Liu Z; Wu Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Mar; 27(3):320-5. PubMed ID: 23672134
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Biomechanical comparison of callus over a locked intramedullary nail in various segmental bone defects in a sheep model.
    Tyllianakis M; Deligianni D; Panagopoulos A; Pappas M; Sourgiadaki E; Mavrilas D; Papadopoulos A
    Med Sci Monit; 2007 May; 13(5):BR125-30. PubMed ID: 17476191
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Spinal fusion of lumbar intertransverse process by using tissue engineered bone with xenogeneic deproteinized cancellous bone as scaffold].
    Gao C; Li Q; Jian Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Feb; 21(2):115-9. PubMed ID: 17357455
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Evaluation of bioabsorbable multiamino acid copolymer/α-tri-calcium phosphate interbody fusion cages in a goat model.
    Chunguang Z; Yueming S; Chongqi T; Hong D; Fuxing P; Yonggang Y; Hong L
    Spine (Phila Pa 1976); 2011 Dec; 36(25):E1615-22. PubMed ID: 21270683
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The effects of infrared low-level laser therapy on healing of partial osteotomy of tibia in streptozotocin-induced diabetic rats.
    Javadieh F; Bayat M; Abdi S; Mohsenifar Z; Razi S
    Photomed Laser Surg; 2009 Aug; 27(4):641-6. PubMed ID: 19694509
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Experimental study of repairing bone defect with tissue engineered bone seeded with autologous red bone marrow and wrapped by pedicled fascial flap].
    Yang X; Shi W; Du Y; Meng X; Yin Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Oct; 23(10):1254-9. PubMed ID: 19957851
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Long-term observation of large weight-bearing bone defect in goats repaired with tissue engineering technique].
    Chen B; Pei GX; Wang K; Tang GH
    Nan Fang Yi Ke Da Xue Xue Bao; 2006 Jun; 26(6):770-3. PubMed ID: 16793597
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Biomechanical evaluation of the relation between number of suture anchors and strength of the bone-tendon interface in a goat rotator cuff model.
    Fealy S; Rodeo SA; MacGillivray JD; Nixon AJ; Adler RS; Warren RF
    Arthroscopy; 2006 Jun; 22(6):595-602. PubMed ID: 16762696
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Plate fixation of prostheses after segmental resection for bone tumours.
    Coathup MJ; Cobb JP; Walker PS; Blunn GW
    J Orthop Res; 2000 Nov; 18(6):865-72. PubMed ID: 11192245
    [TBL] [Abstract][Full Text] [Related]  

  • 50. [Experimental study on promoting bone consolidation by using platelet-rich plasma and decalcified bone matrix during distraction osteogenesis].
    Ni M; Tang P; Wang Y; Li G
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jun; 25(6):661-7. PubMed ID: 21735776
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Calcium phosphate bone cement: a possible alternative to autologous bone graft. A radiological and biomechanical comparison in rat tibial bone.
    Winge MI; Reikerås O; Røkkum M
    Arch Orthop Trauma Surg; 2011 Aug; 131(8):1035-41. PubMed ID: 21305309
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Histological observation of tendon-bone healing after anterior cruciate ligament reconstruction by platelet-rich plasma combined with deproteinized bone of calf].
    Zhao Y; Zhai W
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Nov; 24(11):1323-9. PubMed ID: 21226354
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Relationship to drill bit diameter and residual fracture resistance of the distal tibia.
    McChesney GR; Morris RP; Al Barghouthi A; Travascio F; Latta LL; Lindsey RW
    Clin Biomech (Bristol, Avon); 2022 Jul; 97():105686. PubMed ID: 35679746
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Interface contact profiles of a novel locking plate and its effect on fracture healing in goat.
    Wei DC; Zhao YF; Xing SX; Wang AM
    Chin J Traumatol; 2010 Aug; 13(4):240-3. PubMed ID: 20670582
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Biomechanical study of a unilocking T-plate system for prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.
    Avery CM; Skidmore M; Peden A; Pan J
    Oral Oncol; 2011 Apr; 47(4):268-73. PubMed ID: 21388860
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [The effect of the tibial tunnel fixation level on the results of cyclic loading in anterior cruciate ligament reconstruction].
    Taşer O; Kocabey Y; Doral MN; Demirhan M; Işikan EU; Nyland J; Sarban S; Bozdaği E; Sünbüloğlu E
    Acta Orthop Traumatol Turc; 2005; 39(4):356-60. PubMed ID: 16269885
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The effect of concurrent fibular fracture on the fixation of distal tibia fractures: a laboratory comparison of intramedullary nails with locked plates.
    Strauss EJ; Alfonso D; Kummer FJ; Egol KA; Tejwani NC
    J Orthop Trauma; 2007 Mar; 21(3):172-7. PubMed ID: 17473753
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Development of static three dimensional screw-plate system and the biomechanic features thereof, a comparative study].
    Liang JY; Li KH; Liao QD; Zhu Y; Hu YH; Lei GH
    Zhonghua Yi Xue Za Zhi; 2009 Jan; 89(1):12-6. PubMed ID: 19489236
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [A study on the repair of bone defects with deproteinized bone surrounded by titanium mesh and osteoblasts].
    Zhang Q; Zhao S; Chen W; Huang J; Chu C; Pu Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Apr; 22(2):254-7. PubMed ID: 15884530
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments.
    Sezek S; Aksakal B; Gürger M; Malkoc M; Say Y
    Biomed Mater Eng; 2016 Aug; 27(2-3):197-209. PubMed ID: 27567775
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.