BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 20113520)

  • 41. [Positive end-expiratory pressure adjustment in parenchimal respiratory failure: static pressure-volume loop or transpulmonary pressure?].
    Iaroshetskiĭ AI; Protsenko DN; Rezepov NA; Gel'fand BR
    Anesteziol Reanimatol; 2014; 59(4):53-9. PubMed ID: 25549487
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Electrical impedance tomography for predicting failure of spontaneous breathing trials in patients with prolonged weaning.
    Bickenbach J; Czaplik M; Polier M; Marx G; Marx N; Dreher M
    Crit Care; 2017 Jul; 21(1):177. PubMed ID: 28697778
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Intratidal recruitment/derecruitment persists at low and moderate positive end-expiratory pressure in paediatric patients.
    Wirth S; Artner L; Broß T; Lozano-Zahonero S; Spaeth J; Schumann S
    Respir Physiol Neurobiol; 2016 Dec; 234():9-13. PubMed ID: 27585545
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single centre experience.
    Heines SJH; Strauch U; van de Poll MCG; Roekaerts PMHJ; Bergmans DCJJ
    J Clin Monit Comput; 2019 Apr; 33(2):291-300. PubMed ID: 29845479
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Electrical impedance tomography for lung ventilation monitoring of the dog.
    Gloning S; Pieper K; Zoellner M; Meyer-Lindenberg A
    Tierarztl Prax Ausg K Kleintiere Heimtiere; 2017 Feb; 45(1):15-21. PubMed ID: 28094413
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.
    Lowhagen K; Lundin S; Stenqvist O
    Minerva Anestesiol; 2010 Dec; 76(12):1024-35. PubMed ID: 21178912
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Imaging of regional air distributions in porcine lungs using high-performance electrical impedance tomography system.
    Jang GY; Kim YB; Wi H; Oh TI; Chung CR; Suh GY; Woo EJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():349-351. PubMed ID: 29059882
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography.
    Meier T; Luepschen H; Karsten J; Leibecke T; Grossherr M; Gehring H; Leonhardt S
    Intensive Care Med; 2008 Mar; 34(3):543-50. PubMed ID: 17653529
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels.
    Bikker IG; Leonhardt S; Bakker J; Gommers D
    Intensive Care Med; 2009 Aug; 35(8):1362-7. PubMed ID: 19513694
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Increasing positive end-expiratory pressure (re-)improves intraoperative respiratory mechanics and lung ventilation after prone positioning.
    Spaeth J; Daume K; Goebel U; Wirth S; Schumann S
    Br J Anaesth; 2016 Jun; 116(6):838-46. PubMed ID: 27199315
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Setting positive end-expiratory pressure by using electrical impedance tomography.
    Frerichs I; Schädler D; Becher T
    Curr Opin Crit Care; 2024 Feb; 30(1):43-52. PubMed ID: 38085866
    [TBL] [Abstract][Full Text] [Related]  

  • 52. A randomised trial evaluating mask ventilation using electrical impedance tomography during anesthetic induction: one-handed technique versus two-handed technique.
    Gao L; Zhu Y; Pan C; Yin Y; Zhao Z; Yang L; Zhang J
    Physiol Meas; 2022 Jun; 43(6):. PubMed ID: 35580595
    [No Abstract]   [Full Text] [Related]  

  • 53. Regional expiratory time constants in severe respiratory failure estimated by electrical impedance tomography: a feasibility study.
    Karagiannidis C; Waldmann AD; Róka PL; Schreiber T; Strassmann S; Windisch W; Böhm SH
    Crit Care; 2018 Sep; 22(1):221. PubMed ID: 30236123
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparison of Global and Regional Compliance-Guided Positive End-Expiratory Pressure Titration on Regional Lung Ventilation in Moderate-to-Severe Pediatric Acute Respiratory Distress Syndrome.
    Ren H; Xie L; Wang Z; Tang X; Ning B; Teng T; Qian J; Wang Y; Fu L; Zhao Z; Xiang L
    Front Med (Lausanne); 2022; 9():805680. PubMed ID: 35677825
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution?
    Frerichs I; Dargaville PA; Dudykevych T; Rimensberger PC
    Intensive Care Med; 2003 Dec; 29(12):2312-2316. PubMed ID: 14566457
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Ventilation distribution assessed with electrical impedance tomography and the influence of tidal volume, recruitment and positive end-expiratory pressure in isoflurane-anesthetized dogs.
    Ambrosio AM; Carvalho-Kamakura TPA; Ida KK; Varela B; Andrade FSRM; Facó LL; Fantoni DT
    Vet Anaesth Analg; 2017 Mar; 44(2):254-263. PubMed ID: 28457827
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Monitoring of intratidal lung mechanics: a Graphical User Interface for a model-based decision support system for PEEP-titration in mechanical ventilation.
    Buehler S; Lozano-Zahonero S; Schumann S; Guttmann J
    J Clin Monit Comput; 2014 Dec; 28(6):613-23. PubMed ID: 24549460
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study.
    Richard JC; Pouzot C; Gros A; Tourevieille C; Lebars D; Lavenne F; Frerichs I; Guérin C
    Crit Care; 2009; 13(3):R82. PubMed ID: 19480694
    [TBL] [Abstract][Full Text] [Related]  

  • 59. OPTIMUM LEVEL OF POSITIVE END-EXPIRATORY PRESSURE IN ACUTE RESPIRATORY DISTRESS SYNDROME CAUSED BY INFLUENZA A(H1NI)PDM09: BALANCE BETWEEN MAXIMAL END-EXPIRATORY VOLUME AND MINIMAL ALVEOLAR OVERDISTENSION.
    Yaroshetskiym A I ; Protsenko DN; Boytsov PV; Chentsov VB; Nistratov SL; Kudlyakov ON; Solov'ev VV; Banova ZI; Shkuratova NV; Rezenov NA; Gel'fand BR
    Anesteziol Reanimatol; 2016 Nov; 61(6):425-432. PubMed ID: 29894610
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Impact of PEEP during laparoscopic surgery on early postoperative ventilation distribution visualized by electrical impedance tomography.
    Karsten J; Heinze H; Meier T
    Minerva Anestesiol; 2014 Feb; 80(2):158-66. PubMed ID: 23877309
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.