These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 20117068)

  • 1. Retainer design for unilateral extension base partial removable dental prosthesis by three-dimensional finite element analysis.
    Aoda K; Shimamura I; Tahara Y; Sakurai K
    J Prosthodont Res; 2010 Apr; 54(2):84-91. PubMed ID: 20117068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of loading locations and direct retainers on the movements of the abutment tooth and denture base of removable partial dentures.
    Mizuuchi W; Yatabe M; Sato M; Nishiyama A; Ohyama T
    J Med Dent Sci; 2002 Mar; 49(1):11-8. PubMed ID: 12160222
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of loading positions of mandibular unilateral distal extension removable partial dentures on movements of abutment tooth and denture base.
    Jin X; Sato M; Nishiyama A; Ohyama T
    J Med Dent Sci; 2004 Sep; 51(3):155-63. PubMed ID: 15597821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The mandibular first premolar as an abutment for distal-extension removable partial dentures: a modified clasp assembly design.
    Shifman A; Ben-Ur Z
    Br Dent J; 2000 Mar; 188(5):246-8. PubMed ID: 10758686
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of rigid and nonrigid extracoronal attachments on supporting tissues in extension base partial removable dental prostheses: a nonlinear finite element study.
    Wang HY; Zhang YM; Yao D; Chen JH
    J Prosthet Dent; 2011 May; 105(5):338-46. PubMed ID: 21530760
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Studies on retainer's effect on unilateral designs of mandibular unilateral distal extention dentures].
    Okazaki M
    Nihon Hotetsu Shika Gakkai Zasshi; 1990 Feb; 34(1):40-53. PubMed ID: 2134927
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clasp retention: the effects of five variables.
    LaVere AM
    J Prosthodont; 1993 Jun; 2(2):126-31. PubMed ID: 8242166
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A stress-releasing intracoronal attachment for extension base removable partial dentures.
    Zinner ID; Pines MS; Markovits S; Neurohr FG
    Gen Dent; 1998; 46(4):398-402. PubMed ID: 9758988
    [TBL] [Abstract][Full Text] [Related]  

  • 9. When to choose which retention element to use for removable dental prostheses.
    Zitzmann NU; Rohner U; Weiger R; Krastl G
    Int J Prosthodont; 2009; 22(2):161-7. PubMed ID: 19418863
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Studies on retainer's effect on unilateral designs of mandibular unilateral distal extention dentures. 1].
    Okazaki M
    Nihon Hotetsu Shika Gakkai Zasshi; 1989 Oct; 33(5):1247-60. PubMed ID: 2489769
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Finite element method analysis of the stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part I: the teeth and periodontal ligament).
    Gharechahi J; Sharifi E; Aghdaee NA; Nosohian S
    J Contemp Dent Pract; 2008 Sep; 9(6):65-72. PubMed ID: 18784861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A finite element evaluation of mechanical function for 3 distal extension partial dental prosthesis designs with a 3-dimensional nonlinear method for modeling soft tissue.
    Nakamura Y; Kanbara R; Ochiai KT; Tanaka Y
    J Prosthet Dent; 2014 Oct; 112(4):972-80. PubMed ID: 24819523
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Designing clasps for the asymmetric distal extension removable partial denture.
    Ben-Ur Z; Gorfil C; Shifman A
    Int J Prosthodont; 1996; 9(4):374-8. PubMed ID: 8957876
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of direct retainer and major connector designs on RPD and abutment tooth movement dynamics.
    Itoh H; Baba K; Aridome K; Okada D; Tokuda A; Nishiyama A; Miura H; Igarashi Y
    J Oral Rehabil; 2008 Nov; 35(11):810-5. PubMed ID: 18482346
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effects of buccolingual width and position of occlusal rest seats on load transmission to the abutments for tooth-supported removable partial dentures.
    Sato Y; Hosokawa R; Tsuga K; Kubo T
    Int J Prosthodont; 2001; 14(4):340-3. PubMed ID: 11508089
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation of the effectiveness of indirect retainers.
    Frank RP; Nicholls JI
    J Prosthet Dent; 1977 Nov; 38(5):494-506. PubMed ID: 335050
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Studies on the influences of the indirect retainers on the displacements of the denture bases and the abutment teeth. 2. The forms and locations of indirect retainers used for cross arch stabilizations].
    Saito M
    Nihon Hotetsu Shika Gakkai Zasshi; 1989 Apr; 33(2):337-51. PubMed ID: 2489568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of buccal part designs of polyamide resin partial removable dental prosthesis on retentive force.
    Taguchi Y; Shimamura I; Sakurai K
    J Prosthodont Res; 2011 Jan; 55(1):44-7. PubMed ID: 20971693
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures.
    Tebrock OC; Rohen RM; Fenster RK; Pelleu GB
    J Prosthet Dent; 1979 May; 41(5):511-6. PubMed ID: 374712
    [TBL] [Abstract][Full Text] [Related]  

  • 20. RLS--the lingually retained clasp assembly for distal extension removable partial dentures.
    Aviv I; Ben-Ur Z; Cardash HS; Fatael H
    Quintessence Int; 1990 Mar; 21(3):221-3. PubMed ID: 2197670
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.