BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 20127099)

  • 41. Factors associated with inaccurate size estimation of colorectal polyps: A multicenter cross-sectional study.
    Utsumi T; Horimatsu T; Nishikawa Y; Teramoto A; Hirata D; Iwatate M; Tanaka S; Ikezawa N; Esaki M; Osera S; Ebisutani C; Agatsuma N; Saito H; Sano Y; Seno H
    J Gastroenterol Hepatol; 2021 Aug; 36(8):2224-2229. PubMed ID: 33600621
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Real-time detection of colon polyps during colonoscopy using deep learning: systematic validation with four independent datasets.
    Lee JY; Jeong J; Song EM; Ha C; Lee HJ; Koo JE; Yang DH; Kim N; Byeon JS
    Sci Rep; 2020 May; 10(1):8379. PubMed ID: 32433506
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Validation of a simple classification system for endoscopic diagnosis of small colorectal polyps using narrow-band imaging.
    Hewett DG; Kaltenbach T; Sano Y; Tanaka S; Saunders BP; Ponchon T; Soetikno R; Rex DK
    Gastroenterology; 2012 Sep; 143(3):599-607.e1. PubMed ID: 22609383
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Colonic polyps diagnosis by conventional video colonoscopes and chromoscopy with indigo carmine dye solution].
    Nakao FS; Araújo IS; Ornellas LC; Cury Mde S; Ferrari AP
    Arq Gastroenterol; 2002; 39(2):86-92. PubMed ID: 12612711
    [TBL] [Abstract][Full Text] [Related]  

  • 45. A morphologic analysis of sessile serrated polyps observed during routine colonoscopy (with video).
    Tadepalli US; Feihel D; Miller KM; Itzkowitz SH; Freedman JS; Kornacki S; Cohen LB; Bamji ND; Bodian CA; Aisenberg J
    Gastrointest Endosc; 2011 Dec; 74(6):1360-8. PubMed ID: 22018553
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Polyp morphology: an interobserver evaluation for the Paris classification among international experts.
    van Doorn SC; Hazewinkel Y; East JE; van Leerdam ME; Rastogi A; Pellisé M; Sanduleanu-Dascalescu S; Bastiaansen BA; Fockens P; Dekker E
    Am J Gastroenterol; 2015 Jan; 110(1):180-7. PubMed ID: 25331346
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Does autofluorescence imaging videoendoscopy system improve the colonoscopic polyp detection rate?--a pilot study.
    Matsuda T; Saito Y; Fu KI; Uraoka T; Kobayashi N; Nakajima T; Ikehara H; Mashimo Y; Shimoda T; Murakami Y; Parra-Blanco A; Fujimori T; Saito D
    Am J Gastroenterol; 2008 Aug; 103(8):1926-32. PubMed ID: 18647285
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Improved Accuracy in Optical Diagnosis of Colorectal Polyps Using Convolutional Neural Networks with Visual Explanations.
    Jin EH; Lee D; Bae JH; Kang HY; Kwak MS; Seo JY; Yang JI; Yang SY; Lim SH; Yim JY; Lim JH; Chung GE; Chung SJ; Choi JM; Han YM; Kang SJ; Lee J; Chan Kim H; Kim JS
    Gastroenterology; 2020 Jun; 158(8):2169-2179.e8. PubMed ID: 32119927
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Low magnification narrow band imaging by inexperienced endoscopists has a high accuracy in differentiation of colon polyp histology.
    Seref Köksal A; Yıldız H; Taşkıran I; Turhan N; Oztaş E; Torun S; Kayaçetin E
    Clin Res Hepatol Gastroenterol; 2014 Dec; 38(6):763-9. PubMed ID: 25017818
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Polyp measurement based on CT colonography and colonoscopy: variability and systematic differences.
    de Vries AH; Bipat S; Dekker E; Liedenbaum MH; Florie J; Fockens P; van der Kraan R; Mathus-Vliegen EM; Reitsma JB; Truyen R; Vos FM; Zwinderman AH; Stoker J
    Eur Radiol; 2010 Jun; 20(6):1404-13. PubMed ID: 20033180
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Endoscopic mis-sizing of polyps changes colorectal cancer surveillance recommendations.
    Eichenseer PJ; Dhanekula R; Jakate S; Mobarhan S; Melson JE
    Dis Colon Rectum; 2013 Mar; 56(3):315-21. PubMed ID: 23392145
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Assessment of colorectal polyp recognition skill: development and validation of an objective test.
    Hill A; Horswill MS; Plooy AM; Watson MO; Rowlands LN; Wallis GM; Riek S; Burgess-Limerick R; Hewett DG
    Surg Endosc; 2017 Jun; 31(6):2426-2436. PubMed ID: 27651355
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Is narrow band imaging superior to high-definition white light endoscopy in the assessment of diminutive colorectal polyps?
    Singh R; Bhat YM; Thurairajah PH; Shetti MP; Jayanna M; Nind G; Tam W; Walmsey R; Bourke M; Moss A; Chen R; Bampton P; Roberts-Thomson I; Schoeman M; Tucker G
    J Gastroenterol Hepatol; 2013 Mar; 28(3):472-8. PubMed ID: 23278252
    [TBL] [Abstract][Full Text] [Related]  

  • 54. QuickView video preview software of colon capsule endoscopy: reliability in presenting colorectal polyps as compared to normal mode reading.
    Farnbacher MJ; Krause HH; Hagel AF; Raithel M; Neurath MF; Schneider T
    Scand J Gastroenterol; 2014 Mar; 49(3):339-46. PubMed ID: 24325660
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Randomized controlled study of the prediction of diminutive/small colorectal polyp histology using didactic versus computer-based self-learning module in gastroenterology trainees.
    Smith SCL; Saltzman J; Shivaji UN; Lethebe BC; Cannatelli R; ; Ghosh S; Iacucci M
    Dig Endosc; 2019 Sep; 31(5):535-543. PubMed ID: 30844114
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Diagnostic accuracy of narrow band imaging for predicting colon polyp histology can be affected by polyp characteristics.
    Lee S; Moon CM; Kim YJ; Cho JH; Kim HM; Han KJ; Cho HG; Lee SW; Oh HE; Song JS; Yi SY; Son NH
    Hepatogastroenterology; 2013; 60(125):1028-34. PubMed ID: 23574638
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Use of disposable graduated biopsy forceps improves accuracy of polyp size measurements during endoscopy.
    Jin HY; Leng Q
    World J Gastroenterol; 2015 Jan; 21(2):623-8. PubMed ID: 25605986
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Estimating the size of polyps during actual endoscopy procedures using a spatio-temporal characterization.
    Martínez F; Ruano J; Gómez M; Romero E
    Comput Med Imaging Graph; 2015 Jul; 43():130-6. PubMed ID: 25670148
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Short turn radius colonoscope in an anatomical model: retroflexed withdrawal and detection of hidden polyps.
    McGill SK; Kothari S; Friedland S; Chen A; Park WG; Banerjee S
    World J Gastroenterol; 2015 Jan; 21(2):593-9. PubMed ID: 25593483
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Impact of a computer-based teaching module on characterization of diminutive colon polyps by using narrow-band imaging by non-experts in academic and community practice: a video-based study.
    Rastogi A; Rao DS; Gupta N; Grisolano SW; Buckles DC; Sidorenko E; Bonino J; Matsuda T; Dekker E; Kaltenbach T; Singh R; Wani S; Sharma P; Olyaee MS; Bansal A; East JE
    Gastrointest Endosc; 2014 Mar; 79(3):390-8. PubMed ID: 24021492
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.