BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 20131747)

  • 1. Structural and thermal properties of polypropylene mesh used in treatment of stress urinary incontinence.
    Afonso JS; Jorge RM; Martins PS; Soldi Mda S; Alves OL; Patricio B; Mascarenhas T; Sartori MG; Girao MJ
    Acta Bioeng Biomech; 2009; 11(3):27-33. PubMed ID: 20131747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical properties of polypropylene mesh used in pelvic floor repair.
    Afonso JS; Martins PA; Girao MJ; Natal Jorge RM; Ferreira AJ; Mascarenhas T; Fernandes AA; Bernardes J; Baracat EC; Rodrigues de Lima G; Patricio B
    Int Urogynecol J Pelvic Floor Dysfunct; 2008 Mar; 19(3):375-80. PubMed ID: 17846702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The challenge of stress incontinence and pelvic organ prolapse: revisiting biologic mesh materials.
    D'Angelo W; Dziki J; Badylak SF
    Curr Opin Urol; 2019 Jul; 29(4):437-442. PubMed ID: 31083010
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vivo response to polypropylene following implantation in animal models: a review of biocompatibility.
    Kelly M; Macdougall K; Olabisi O; McGuire N
    Int Urogynecol J; 2017 Feb; 28(2):171-180. PubMed ID: 27216918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Selective laser vaporization of polypropylene mesh used in treatment of female stress urinary incontinence and pelvic organ prolapse: preliminary studies using a red diode laser.
    Burks D; Rosenbury SB; Kennelly MJ; Fried NM
    Lasers Surg Med; 2012 Apr; 44(4):325-9. PubMed ID: 22430642
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative study of polypropylene and aponeurotic slings in the treatment of female urinary incontinence.
    Winckler JA; Ramos JG; Dalmolin BM; Winckler DC; Doring M
    Int Braz J Urol; 2010; 36(3):339-47. PubMed ID: 20602827
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The myth: in vivo degradation of polypropylene-based meshes.
    Thames SF; White JB; Ong KL
    Int Urogynecol J; 2017 Feb; 28(2):285-297. PubMed ID: 27600700
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Urethral Diverticulum following Polypropylene Mesh Midurethral Slings: A Literature Review.
    Pacer E; Duenas-Garcia OF; Hota L; Hornsby K; Shapiro R
    Biomed Res Int; 2020; 2020():6761581. PubMed ID: 32462011
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Complications of synthetic mesh inserted for stress urinary incontinence.
    Morton S; Wilczek Y; Harding C
    BJU Int; 2021 Jan; 127(1):4-11. PubMed ID: 32981191
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Oxidation and degradation of polypropylene transvaginal mesh.
    Talley AD; Rogers BR; Iakovlev V; Dunn RF; Guelcher SA
    J Biomater Sci Polym Ed; 2017 Apr; 28(5):444-458. PubMed ID: 28081670
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Do preoperative cytokine levels offer a prognostic factor for polypropylene mesh erosion after suburethral sling surgery for stress urinary incontinence?
    Rechberger T; Jankiewicz K; Adamiak A; Miotla P; Chrobak A; Jerzak M
    Int Urogynecol J Pelvic Floor Dysfunct; 2009 Jan; 20(1):69-74. PubMed ID: 18841321
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Tape erosion--local process or general reaction of the organism. The erosion rate and localization of implanted polypropylene tape in female pelvis].
    Adamiak A; Jankiewicz K; Miotła P; Rechberger T
    Ginekol Pol; 2007 Mar; 78(3):210-3. PubMed ID: 17650902
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Management of vaginal erosion of polypropylene mesh slings.
    Kobashi KC; Govier FE
    J Urol; 2003 Jun; 169(6):2242-3. PubMed ID: 12771759
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparative study among autologous and synthetic slings in the treatment of stress urinary incontinence].
    De Vita D; Araco F; Aydar Natalin R; Riccetto C; Nardi Pedro R; Palma P
    Minerva Ginecol; 2008 Dec; 60(6):469-73. PubMed ID: 18981974
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polypropylene mesh tape for stress urinary incontinence: complications of urethral erosion and outlet obstruction.
    Sweat SD; Itano NB; Clemens JQ; Bushman W; Gruenenfelder J; McGuire EJ; Lightner DJ
    J Urol; 2002 Jul; 168(1):144-6. PubMed ID: 12050509
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluating Alternative Materials for the Treatment of Stress Urinary Incontinence and Pelvic Organ Prolapse: A Comparison of the In Vivo Response to Meshes Implanted in Rabbits.
    Roman S; Urbánková I; Callewaert G; Lesage F; Hillary C; Osman NI; Chapple CR; Deprest J; MacNeil S
    J Urol; 2016 Jul; 196(1):261-9. PubMed ID: 26880411
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biodegradable materials for surgical management of stress urinary incontinence: A narrative review.
    MacCraith E; O'Brien FJ; Davis NF
    Eur J Obstet Gynecol Reprod Biol; 2021 Apr; 259():153-160. PubMed ID: 33676124
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk factors for mesh erosion after vaginal sling procedures for urinary incontinence.
    Kokanali MK; Doğanay M; Aksakal O; Cavkaytar S; Topçu HO; Özer İ
    Eur J Obstet Gynecol Reprod Biol; 2014 Jun; 177():146-50. PubMed ID: 24793930
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Materials characterization of explanted polypropylene hernia mesh: Patient factor correlation.
    Smith SE; Cozad MJ; Grant DA; Ramshaw BJ; Grant SA
    J Biomater Appl; 2016 Feb; 30(7):1026-35. PubMed ID: 26454268
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of synthetic sub-urethral slings in the treatment of female stress urinary incontinence.
    Feifer A; Corcos J
    Int Urogynecol J Pelvic Floor Dysfunct; 2007 Sep; 18(9):1087-95. PubMed ID: 17464439
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.