433 related articles for article (PubMed ID: 20136128)
1. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
Tai SS; Bedner M; Phinney KW
Anal Chem; 2010 Mar; 82(5):1942-8. PubMed ID: 20136128
[TBL] [Abstract][Full Text] [Related]
2. A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D₃ and 25-hydroxyvitamin D₂ using isotope-dilution liquid chromatography-tandem mass spectrometry.
Mineva EM; Schleicher RL; Chaudhary-Webb M; Maw KL; Botelho JC; Vesper HW; Pfeiffer CM
Anal Bioanal Chem; 2015 Jul; 407(19):5615-24. PubMed ID: 25967149
[TBL] [Abstract][Full Text] [Related]
3. Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.
Tai SS; Nelson MA
Anal Chem; 2015 Aug; 87(15):7964-70. PubMed ID: 26171884
[TBL] [Abstract][Full Text] [Related]
4. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry.
Stepman HC; Vanderroost A; Van Uytfanghe K; Thienpont LM
Clin Chem; 2011 Mar; 57(3):441-8. PubMed ID: 21248072
[TBL] [Abstract][Full Text] [Related]
5. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
[TBL] [Abstract][Full Text] [Related]
6. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
van den Ouweland JM; Beijers AM; van Daal H
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396
[TBL] [Abstract][Full Text] [Related]
7. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
[TBL] [Abstract][Full Text] [Related]
8. A candidate reference method and multiple commutable control materials for serum 25-hydroxyvitamin D measurement.
Zhang L; Long Q; Zhang J; Zeng Q; Zhao H; Chen W; Zhang T; Zhang C
J Clin Lab Anal; 2022 Dec; 36(12):e24756. PubMed ID: 36371780
[TBL] [Abstract][Full Text] [Related]
9. Vitamin D Status in Children With Short Stature: Accurate Determination of Serum Vitamin D Components Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry.
Xu B; Feng Y; Gan L; Zhang Y; Jiang W; Feng J; Yu L
Front Endocrinol (Lausanne); 2021; 12():707283. PubMed ID: 34721288
[TBL] [Abstract][Full Text] [Related]
10. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
[TBL] [Abstract][Full Text] [Related]
11. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3.
Netzel BC; Cradic KW; Bro ET; Girtman AB; Cyr RC; Singh RJ; Grebe SK
Clin Chem; 2011 Mar; 57(3):431-40. PubMed ID: 21245371
[TBL] [Abstract][Full Text] [Related]
12. Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: a comparative study.
Bogusz MJ; Al Enazi E; Tahtamoni M; Jawaad JA; Al Tufail M
Clin Biochem; 2011 Nov; 44(16):1329-37. PubMed ID: 21907190
[TBL] [Abstract][Full Text] [Related]
13. Rapid liquid chromatography-tandem mass spectrometry method for determination of 24,25(OH)
Yu S; Zhou W; Wang D; Yin Y; Cheng Q; Xie S; Sun D; Li H; Cheng X; Qiu L
J Steroid Biochem Mol Biol; 2019 Mar; 187():146-151. PubMed ID: 30476592
[TBL] [Abstract][Full Text] [Related]
14. Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum.
Schleicher RL; Encisco SE; Chaudhary-Webb M; Paliakov E; McCoy LF; Pfeiffer CM
Clin Chim Acta; 2011 Aug; 412(17-18):1594-9. PubMed ID: 21601563
[TBL] [Abstract][Full Text] [Related]
15. Development of a sensitive HPLC-MS/MS method for 25-hydroxyvitamin D
Jiao X; Yuan Y; Wang X; Li J; Liu B; Yuan T; Yu X
J Clin Lab Anal; 2020 Oct; 34(10):e23451. PubMed ID: 32592276
[TBL] [Abstract][Full Text] [Related]
16. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D
Wise SA; Camara JE; Burdette CQ; Hahm G; Nalin F; Kuszak AJ; Merkel J; Durazo-Arvizu RA; Williams EL; Hoofnagle AN; Ivison F; Fischer R; van den Ouweland JMW; Ho CS; Law EWK; Simard JN; Gonthier R; Holmquist B; Meadows S; Cox L; Robyak K; Creer MH; Fitzgerald R; Clarke MW; Breen N; Lukas P; Cavalier É; Sempos CT
Anal Bioanal Chem; 2022 Jan; 414(1):333-349. PubMed ID: 34432104
[TBL] [Abstract][Full Text] [Related]
17. [Measurement of 25-hydroxyvitamin D3 in human serum by liquid chromatography-tandem mass spectrometry and the control for analytical conditions].
Zheng X; Ma A; Zhang H; Wang Z; Wang Q; Liang H
Wei Sheng Yan Jiu; 2012 May; 41(3):485-8, 492. PubMed ID: 23050454
[TBL] [Abstract][Full Text] [Related]
18. A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.
Garg U; Munar A; Frazee C; Scott D
J Clin Lab Anal; 2012 Sep; 26(5):349-57. PubMed ID: 23001980
[TBL] [Abstract][Full Text] [Related]
19. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method.
Chen H; McCoy LF; Schleicher RL; Pfeiffer CM
Clin Chim Acta; 2008 May; 391(1-2):6-12. PubMed ID: 18279671
[TBL] [Abstract][Full Text] [Related]
20. A liquid chromatography/tandem mass spectrometry method for determination of 25-hydroxy vitamin D2 and 25-hydroxy vitamin D3 in dried blood spots: a potential adjunct to diabetes and cardiometabolic risk screening.
Newman MS; Brandon TR; Groves MN; Gregory WL; Kapur S; Zava DT
J Diabetes Sci Technol; 2009 Jan; 3(1):156-62. PubMed ID: 20046660
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]