These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

64 related articles for article (PubMed ID: 20139559)

  • 1. Canal-centring ability of three rotary file systems in simulated curved canals: a comparative study.
    Khalilak Z; Alavi K; Akhlaghi NM; Mehrvarzfar P; Dadresanfar B
    Indian J Dent Res; 2009; 20(4):400-3. PubMed ID: 20139559
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shaping ability of ProTaper nickel-titanium files in simulated resin root canals.
    Calberson FL; Deroose CA; Hommez GM; De Moor RJ
    Int Endod J; 2004 Sep; 37(9):613-23. PubMed ID: 15317565
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals.
    Schäfer E
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2001 Aug; 92(2):215-20. PubMed ID: 11505270
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the centreing ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files.
    Aguiar CM; de Andrade Mendes D; Câmara AC; de Figueiredo JA
    Aust Endod J; 2009 Dec; 35(3):174-9. PubMed ID: 19961458
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shaping ability of GTTM Rotary Files in simulated resin root canals.
    Calberson FL; Deroose CA; Hommez GM; Raes H; De Moor RJ
    Int Endod J; 2002 Jul; 35(7):607-14. PubMed ID: 12190900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effectiveness of two nickel-titanium rotary instruments and a hand file for removing gutta-percha in severely curved root canals during retreatment: an ex vivo study.
    Gergi R; Sabbagh C
    Int Endod J; 2007 Jul; 40(7):532-7. PubMed ID: 17511787
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of the shaping ability of RaCe and FlexMaster rotary nickel-titanium systems in simulated canals.
    Merrett SJ; Bryant ST; Dummer PM
    J Endod; 2006 Oct; 32(10):960-2. PubMed ID: 16982273
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals.
    Schäfer E; Vlassis M
    Int Endod J; 2004 Apr; 37(4):229-38. PubMed ID: 15056349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Shaping ability of ProFile and K3 rotary Ni-Ti instruments when used in a variable tip sequence in simulated curved root canals.
    Ayar LR; Love RM
    Int Endod J; 2004 Sep; 37(9):593-601. PubMed ID: 15317562
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of different types of automated devices on the shaping ability of rotary nickel-titanium FlexMaster instruments.
    Schäfer E; Erler M; Dammaschke T
    Int Endod J; 2005 Sep; 38(9):627-36. PubMed ID: 16104976
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.
    Schäfer E; Vlassis M
    Int Endod J; 2004 Apr; 37(4):239-48. PubMed ID: 15056350
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals.
    Schäfer E; Erler M; Dammaschke T
    Int Endod J; 2006 Mar; 39(3):196-202. PubMed ID: 16507073
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modeling capacity of ENDOflash files in simulated root canals.
    Fariniuk LF; Baratto-Filho F; Guerisoli DM; Barbizam JV; Pécora JD; Sousa-Neto MD
    Braz Dent J; 2001; 12(1):39-42. PubMed ID: 11210250
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Centring ability and apical transportation after overinstrumentation with ProTaper Universal and ProFile Vortex instruments.
    González Sánchez JA; Duran-Sindreu F; de Noé S; Mercadé M; Roig M
    Int Endod J; 2012 Jun; 45(6):542-51. PubMed ID: 22264187
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of root canal curvatures before and after canal preparation (part II): A method based on numeric calculus.
    Sonntag D; Stachniss-Carp S; Stachniss C; Stachniss V
    Aust Endod J; 2006 Apr; 32(1):16-25. PubMed ID: 16603041
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The quality of apical canal preparation using hand and rotary instruments with specific criteria for enlargement based on initial apical file size.
    Tan BT; Messer HH
    J Endod; 2002 Sep; 28(9):658-64. PubMed ID: 12236311
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Efficacy of rotary instruments with greater taper in preparing oval root canals.
    Elayouti A; Chu AL; Kimionis I; Klein C; Weiger R; Löst C
    Int Endod J; 2008 Dec; 41(12):1088-92. PubMed ID: 19133098
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effectiveness of a manual glide path on the preparation of curved root canals by using Mtwo rotary instruments.
    Uroz-Torres D; González-Rodríguez MP; Ferrer-Luque CM
    J Endod; 2009 May; 35(5):699-702. PubMed ID: 19410086
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals.
    Yun HH; Kim SK
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2003 Feb; 95(2):228-33. PubMed ID: 12582365
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of root canal preparation with two rotary NiTi instruments: ProFile .04 and GT Rotary.
    Rödig T; Hülsmann M; Kahlmeier C
    Int Endod J; 2007 Jul; 40(7):553-62. PubMed ID: 17511784
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.