334 related articles for article (PubMed ID: 20141814)
1. Comparison of cutting efficiencies between electric and air-turbine dental handpieces.
Choi C; Driscoll CF; Romberg E
J Prosthet Dent; 2010 Feb; 103(2):101-7. PubMed ID: 20141814
[TBL] [Abstract][Full Text] [Related]
2. Comparison of the cutting efficiencies of electric motor and air turbine dental handpieces.
Eikenberg SL
Gen Dent; 2001; 49(2):199-204. PubMed ID: 12004701
[TBL] [Abstract][Full Text] [Related]
3. In vitro comparison of the cutting efficiency and temperature production of ten different rotary cutting instruments. Part II: electric handpiece and comparison with turbine.
Ercoli C; Rotella M; Funkenbusch PD; Russell S; Feng C
J Prosthet Dent; 2009 May; 101(5):319-31. PubMed ID: 19410066
[TBL] [Abstract][Full Text] [Related]
4. Ceramic implant abutments: cutting efficiency and resultant surface finish by diamond rotary cutting instruments.
Park SW; Driscoll CF; Romberg EE; Siegel S; Thompson G
J Prosthet Dent; 2006 Jun; 95(6):444-9. PubMed ID: 16765157
[TBL] [Abstract][Full Text] [Related]
5. Performance of single-use and multiuse diamond rotary cutting instruments with turbine and electric handpieces.
Rotella M; Ercoli C; Funkenbusch PD; Russell S; Feng C
J Prosthet Dent; 2014 Jan; 111(1):56-63. PubMed ID: 24246370
[TBL] [Abstract][Full Text] [Related]
6. Influence of oscillating and rotary cutting instruments with electric and turbine handpieces on tooth preparation surfaces.
Geminiani A; Abdel-Azim T; Ercoli C; Feng C; Meirelles L; Massironi D
J Prosthet Dent; 2014 Jul; 112(1):51-8. PubMed ID: 24726596
[TBL] [Abstract][Full Text] [Related]
7. In vitro comparison of the cutting efficiency and temperature production of 10 different rotary cutting instruments. Part I: Turbine.
Ercoli C; Rotella M; Funkenbusch PD; Russell S; Feng C
J Prosthet Dent; 2009 Apr; 101(4):248-61. PubMed ID: 19328278
[TBL] [Abstract][Full Text] [Related]
8. Changes in the cutting efficiency of different types of dental diamond rotary instrument with repeated cuts and disinfection.
Bae JH; Yi J; Kim S; Shim JS; Lee KW
J Prosthet Dent; 2014 Jan; 111(1):64-70. PubMed ID: 24231434
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.
Vásquez VZ; Ozcan M; Kimpara ET
Dent Mater; 2009 Feb; 25(2):221-31. PubMed ID: 18718654
[TBL] [Abstract][Full Text] [Related]
10. Handpiece coolant flow rates and dental cutting.
von Fraunhofer JA; Siegel SC; Feldman S
Oper Dent; 2000; 25(6):544-8. PubMed ID: 11203868
[TBL] [Abstract][Full Text] [Related]
11. Comparing cutting efficiencies of diamond burs using a high-speed electric handpiece.
Chung EM; Sung EC; Wu B; Caputo AA
Gen Dent; 2006; 54(4):254-7. PubMed ID: 16903197
[TBL] [Abstract][Full Text] [Related]
12. Cutting effectiveness and wear of carbide burs on eight machinable ceramics and bovine dentin.
Tanaka N; Taira M; Wakasa K; Shintani H; Yamaki M
Dent Mater; 1991 Oct; 7(4):247-53. PubMed ID: 1814771
[TBL] [Abstract][Full Text] [Related]
13. The magnitude of cutting forces at high speed.
Elias K; Amis AA; Setchell DJ
J Prosthet Dent; 2003 Mar; 89(3):286-91. PubMed ID: 12644805
[TBL] [Abstract][Full Text] [Related]
14. Colorimetric analysis of opaque porcelain fired to different base metal alloys used in metal ceramic restorations.
Ozcelik TB; Yilmaz B; Ozcan I; Kircelli C
J Prosthet Dent; 2008 Mar; 99(3):193-202. PubMed ID: 18319090
[TBL] [Abstract][Full Text] [Related]
15. Flexural and shear strengths of ZrO2 and a high-noble alloy bonded to their corresponding porcelains.
Ashkanani HM; Raigrodski AJ; Flinn BD; Heindl H; Mancl LA
J Prosthet Dent; 2008 Oct; 100(4):274-84. PubMed ID: 18922256
[TBL] [Abstract][Full Text] [Related]
16. Relative translucency of six all-ceramic systems. Part II: core and veneer materials.
Heffernan MJ; Aquilino SA; Diaz-Arnold AM; Haselton DR; Stanford CM; Vargas MA
J Prosthet Dent; 2002 Jul; 88(1):10-5. PubMed ID: 12239473
[TBL] [Abstract][Full Text] [Related]
17. Relative translucency of six all-ceramic systems. Part I: core materials.
Heffernan MJ; Aquilino SA; Diaz-Arnold AM; Haselton DR; Stanford CM; Vargas MA
J Prosthet Dent; 2002 Jul; 88(1):4-9. PubMed ID: 12239472
[TBL] [Abstract][Full Text] [Related]
18. All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.
Vult von Steyern P
Swed Dent J Suppl; 2005; (173):1-69. PubMed ID: 16001730
[TBL] [Abstract][Full Text] [Related]
19. [Development of new type plastics air turbine handpiece for dental use].
Kusano M
Osaka Daigaku Shigaku Zasshi; 1989 Jun; 34(1):174-92. PubMed ID: 2637348
[TBL] [Abstract][Full Text] [Related]
20. Metal surface treatment: characterization and effect on composite-to-metal bond strength.
Cobb DS; Vargas MA; Fridrich TA; Bouschlicher MR
Oper Dent; 2000; 25(5):427-33. PubMed ID: 11203852
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]