BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 20142184)

  • 1. A third generation ultra-thin strut cobalt chromium stent: histopathological evaluation in porcine coronary arteries.
    Jabara R; Geva S; Ribeiro HB; Chen JP; Hou D; Li J; King SB; Chronos N; Robinson KA
    EuroIntervention; 2009 Nov; 5(5):619-26. PubMed ID: 20142184
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Randomized comparative trial of a thin-strut bare metal cobalt-chromium stent versus a sirolimus-eluting stent for coronary revascularization.
    Ortolani P; Marzocchi A; Marrozzini C; Palmerini T; Saia F; Taglieri N; Aquilina M; Baldazzi F; Silenzi S; Cooke RM; Reggiani ML; Branzi A
    Catheter Cardiovasc Interv; 2007 May; 69(6):790-8. PubMed ID: 17290437
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative preclinical evaluation of a polymer-free sirolimus-eluting stent in porcine coronary arteries.
    Sperling C; Waliszewski MW; Kherad B; Krackhardt F
    Ther Adv Cardiovasc Dis; 2019; 13():1753944719826335. PubMed ID: 30803407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect on Clinical Restenosis of an Ultra-Thin-Strut Bare Metal Cobalt-Chromium Stent Versus a Thin-Strut Stainless Steel Stent.
    Silenzi S; Grossi P; Mariani L; Fraccaro C; Vagnarelli F; Moretti L
    J Interv Cardiol; 2016 Jun; 29(3):300-10. PubMed ID: 27242170
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.
    Jabara R; Chronos N; Conway D; Molema W; Robinson K
    JACC Cardiovasc Interv; 2008 Feb; 1(1):81-7. PubMed ID: 19393150
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model.
    Cilingiroglu M; Elliott J; Sangi P; Matthews H; Tio F; Trauthen B; Elicker J; Bailey SR
    EuroIntervention; 2009 Jan; 4(4):534-41. PubMed ID: 19284078
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel fully bioabsorbable salicylate-based sirolimus-eluting stent.
    Jabara R; Pendyala L; Geva S; Chen J; Chronos N; Robinson K
    EuroIntervention; 2009 Dec; 5 Suppl F():F58-64. PubMed ID: 22100678
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR
    Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation.
    Koppara T; Joner M; Bayer G; Steigerwald K; Diener T; Wittchow E
    Thromb Haemost; 2012 Jun; 107(6):1161-71. PubMed ID: 22535188
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nobori stent shows less vascular inflammation and early recovery of endothelial function compared with Cypher stent.
    Pendyala LK; Matsumoto D; Shinke T; Iwasaki T; Sugimoto R; Hou D; Chen JP; Singh J; King SB; Chronos N; Li J
    JACC Cardiovasc Interv; 2012 Apr; 5(4):436-44. PubMed ID: 22516402
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of drug-eluting stent on inflammation during restenosis in a porcine coronary model.
    Ge H; Zhou Y; Hanying M; Liu L; Nie X; Wang Z; Wang F
    Acta Cardiol; 2010 Feb; 65(1):31-5. PubMed ID: 20306887
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental efficacy of an everolimus eluting cobalt chromium stent.
    Carter AJ; Brodeur A; Collingwood R; Ross S; Gibson L; Wang CA; Haller S; Coleman L; Virmani R
    Catheter Cardiovasc Interv; 2006 Jul; 68(1):97-103. PubMed ID: 16755598
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of angiographic late loss with neointimal proliferation in stents evaluated by OCT and histology in porcine coronary arteries.
    Kim JS; Wallace-Bradley D; Alviar CL; Conditt G; Milewski K; Afari ME; Cheng Y; Gallego C; Tellez A; Stone GW; Kaluza GL; Granada JF
    JACC Cardiovasc Imaging; 2011 Sep; 4(9):1002-10. PubMed ID: 21920339
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bifurcation Optimisation Stent System (BiOSS Lim) with sirolimus elution: results from porcine coronary artery model.
    Vassilev D; Gil R; Milewski K
    EuroIntervention; 2011 Sep; 7(5):614-20. PubMed ID: 21930466
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intimal proliferation and restenosis in paclitaxel-eluting stents with aminoparylene as carrier substance in swines.
    Flueckiger A; Strahm Y; Billinger M; Meier P; Mettler D; Studer U; Schaffner T; Hess OM
    J Invasive Cardiol; 2009 Mar; 21(3):128-32. PubMed ID: 19258644
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Angiographic and histological results following implantation of a novel stent-on-a-wire in the animal model.
    Diletti R; Garcia-Garcia HM; van Geuns RJ; Farooq V; Bailey L; Rousselle S; Kopia G; Easterbrook W; Pomeranz M; Serruys PW
    EuroIntervention; 2012 Jul; 8(3):390-9. PubMed ID: 22377624
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-dose paclitaxel elution by novel bioerodible sol-gel coating on stents inhibits neointima with low toxicity in porcine coronary arteries.
    Shinke T; Geva S; Pendyala L; Jabara R; Li J; Chen JP; Venegoni A; Colley K; Klein R; Chronos N; Robinson K; Hou D
    Int J Cardiol; 2009 Jun; 135(1):93-101. PubMed ID: 18692915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intravascular ultrasound analysis of small vessel lesions treated with the Sparrow coronary stent system: results of the CARE II trial.
    Kume T; Waseda K; Koo BK; Yock PG; Botelho R; Verheye S; Whitbourn R; Meredith I; Worthley S; Hai KT; Honda Y; Abizaid A; Fitzgerald PJ
    Catheter Cardiovasc Interv; 2014 Jan; 83(1):19-24. PubMed ID: 23413202
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term effects on vascular healing of bare metal stents delivered via paclitaxel-coated balloons in the porcine model of restenosis.
    Cremers B; Milewski K; Clever YP; Aboodi MS; Biedermann M; Thim T; Kelsch B; Kaluza GL; Scheller B; Granada JF
    Catheter Cardiovasc Interv; 2012 Oct; 80(4):603-10. PubMed ID: 22511557
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.