71 related articles for article (PubMed ID: 2014472)
1. [Determinant factors and disturbances in controlling power distribution patterns by the hyperthermia-ring system BSD-2000. 2. Measuring techniques and analysis].
Wust P; Nadobny J; Fähling H; Riess H; Koch K; John W; Felix R
Strahlenther Onkol; 1991 Mar; 167(3):172-80. PubMed ID: 2014472
[TBL] [Abstract][Full Text] [Related]
2. [The influencing factors and interfering effects in the control of the power distributions with the BSD-20000 hyperthermia ring system. 1. The clinical observables and phantom measurements].
Wust P; Nadobny J; Fähling H; Riess H; Koch K; John W; Felix R
Strahlenther Onkol; 1990 Dec; 166(12):822-30. PubMed ID: 2267660
[TBL] [Abstract][Full Text] [Related]
3. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom.
Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P
Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620
[TBL] [Abstract][Full Text] [Related]
4. [Investigational study of various kinds of problems in heating methods. Regarding equipment. The BSD-1000 hyperthermia system].
Tsukada A
Gan No Rinsho; 1986 Oct; 32(13):1644-51. PubMed ID: 3795484
[TBL] [Abstract][Full Text] [Related]
5. [The characterization of semirigid coaxial antennae for interstitial and endocavitary microwave hyperthermia].
Erb J; Klautke G; Seegenschmiedt HM; Engelbrecht R; Schaller G; Sauer R
Strahlenther Onkol; 1994 Nov; 170(11):654-64. PubMed ID: 7974181
[TBL] [Abstract][Full Text] [Related]
6. Experimental investigation of an adaptive feedback algorithm for hot spot reduction in radio-frequency phased-array hyperthermia.
Fenn AJ; King GA
IEEE Trans Biomed Eng; 1996 Mar; 43(3):273-80. PubMed ID: 8682539
[TBL] [Abstract][Full Text] [Related]
7. Antenna arrays in the SIGMA-eye applicator: interactions and transforming networks.
Wust P; Fähling H; Wlodarczyk W; Seebass M; Gellermann J; Deuflhard P; Nadobny J
Med Phys; 2001 Aug; 28(8):1793-805. PubMed ID: 11548952
[TBL] [Abstract][Full Text] [Related]
8. [Part-body hyperthermia with a radiofrequency multiantenna applicator under online control in a 1.5 T MR-tomograph].
Wust P; Gellermann J; Seebass M; Fähling H; Turner P; Wlodarczyk W; Nadobny J; Rau B; Hildebrandt B; Oppelt A; Schlag PM; Felix R
Rofo; 2004 Mar; 176(3):363-74. PubMed ID: 15026950
[TBL] [Abstract][Full Text] [Related]
9. Quality control of the SIGMA applicator using a lamp phantom: a four-centre comparison.
Wust P; Fähling H; Felix R; Rahman S; Issels RD; Feldmann H; van Rhoon G; van der Zee J
Int J Hyperthermia; 1995; 11(6):755-67; discussion 867, 869. PubMed ID: 8586898
[TBL] [Abstract][Full Text] [Related]
10. Experimental and clinical evaluation of a prototype hyperthermia system.
Uozumi H; Baba Y; Yasunaga T; Takahashi M
Radiat Med; 1987; 5(4):142-50. PubMed ID: 3321198
[TBL] [Abstract][Full Text] [Related]
11. [Evaluation of ultrasound hyperthermia system with a phantom model].
Ono S; Hirose T; Shiba T; Kuriya K; Watanabe K
Nihon Igaku Hoshasen Gakkai Zasshi; 1996 Mar; 56(4):195-200. PubMed ID: 8992456
[TBL] [Abstract][Full Text] [Related]
12. Heating patterns generated by phase modulation of a hexagonal array of interstitial antennas.
Zhang Y; Joines WT; Oleson JR
IEEE Trans Biomed Eng; 1991 Jan; 38(1):92-7. PubMed ID: 2026438
[TBL] [Abstract][Full Text] [Related]
13. Low-frequency RF hyperthermia: IV--A 27 MHz hybrid applicator for localized deep tumor heating.
Franconi C; Raganella L; Tiberio CA
IEEE Trans Biomed Eng; 1991 Mar; 38(3):287-93. PubMed ID: 2066143
[TBL] [Abstract][Full Text] [Related]
14. Scanning E-field sensor device for online measurements in annular phased-array systems.
Wust P; Berger J; Fähling H; Nadobny J; Gellermann J; Tilly W; Rau B; Petermann K; Felix R
Int J Radiat Oncol Biol Phys; 1999 Mar; 43(4):927-37. PubMed ID: 10098449
[TBL] [Abstract][Full Text] [Related]
15. Stability and accuracy of power and phase measurements of a VVM system designed for online quality control of the BSD-2000 (-3D) DHT system.
Lee WM; Ameziane A; van den Biggelaar AM; Rietveld PJ; van Rhoon GC
Int J Hyperthermia; 2003; 19(1):74-88. PubMed ID: 12519713
[TBL] [Abstract][Full Text] [Related]
16. The use of a current sheet applicator array for superficial hyperthermia: incoherent versus coherent operation.
Prior MV; Lumori ML; Hand JW; Lamaitre G; Schneider CJ; van Dijk JD
IEEE Trans Biomed Eng; 1995 Jul; 42(7):694-8. PubMed ID: 7622152
[TBL] [Abstract][Full Text] [Related]
17. Analysis and optimization of waveguide multiapplicator hyperthermia systems.
Boag A; Leviatan Y; Boag A
IEEE Trans Biomed Eng; 1993 Sep; 40(9):946-52. PubMed ID: 8288286
[TBL] [Abstract][Full Text] [Related]
18. Quantitative validation of the 3D SAR profile of hyperthermia applicators using the gamma method.
de Bruijne M; Samaras T; Chavannes N; van Rhoon GC
Phys Med Biol; 2007 Jun; 52(11):3075-88. PubMed ID: 17505090
[TBL] [Abstract][Full Text] [Related]
19. Quality assurance in various radiative hyperthermia systems applying a phantom with LED matrix.
Schneider CJ; van Dijk JD; De Leeuw AA; Wust P; Baumhoer W
Int J Hyperthermia; 1994; 10(5):733-47. PubMed ID: 7806928
[TBL] [Abstract][Full Text] [Related]
20. Theoretical investigation of measurement procedures for the quality assurance of superficial hyperthermia applicators.
Samaras T; van Rhoon GC; Sahalos JN
Int J Hyperthermia; 2002; 18(5):416-25. PubMed ID: 12227928
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]