These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
485 related articles for article (PubMed ID: 20151773)
21. Clinical performance of the TRUE2go blood glucose system--a novel integrated system for meter and strips. Kipnes MS; Joseph H; Morris H; Manko J; Bell DE Diabetes Technol Ther; 2009 Oct; 11(10):649-55. PubMed ID: 19821757 [TBL] [Abstract][Full Text] [Related]
22. The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System. Bailey T; Bode BW; Christiansen MP; Klaff LJ; Alva S Diabetes Technol Ther; 2015 Nov; 17(11):787-94. PubMed ID: 26171659 [TBL] [Abstract][Full Text] [Related]
23. Accuracy of self monitoring blood glucose systems in a clinical setting: application of new planned ISO- standards. Hasslacher C; Kulozik F; Platten I Clin Lab; 2013; 59(7-8):727-33. PubMed ID: 24133899 [TBL] [Abstract][Full Text] [Related]
24. Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. Tack C; Pohlmeier H; Behnke T; Schmid V; Grenningloh M; Forst T; Pfützner A Diabetes Technol Ther; 2012 Apr; 14(4):330-7. PubMed ID: 22176154 [TBL] [Abstract][Full Text] [Related]
25. Evaluation of Four Blood Glucose Monitoring Systems for Self-Testing with Built-in Insulin Dose Advisor Based on ISO 15197:2013: System Accuracy and Hematocrit Influence. Jendrike N; Baumstark A; Pleus S; Liebing C; Beer A; Flacke F; Haug C; Freckmann G Diabetes Technol Ther; 2018 Apr; 20(4):303-313. PubMed ID: 29664706 [TBL] [Abstract][Full Text] [Related]
26. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors. Baumstark A; Jendrike N; Pleus S; Haug C; Freckmann G Diabetes Technol Ther; 2017 Oct; 19(10):580-588. PubMed ID: 28704063 [TBL] [Abstract][Full Text] [Related]
27. Performance of the DIDGET blood glucose monitoring system in children, teens, and young adults. Deeb LC; Parkes JL; Pardo S; Schachner HC; Viggiani MT; Wallace J; Bailey T J Diabetes Sci Technol; 2011 Sep; 5(5):1157-63. PubMed ID: 22027310 [TBL] [Abstract][Full Text] [Related]
28. Accuracy of a first-generation intravenous blood glucose monitoring system in subjects with diabetes mellitus: a multicenter study. Bailey T; Gulino A; Higgins MJ; Leach J; Kamath A; Simpson PC J Diabetes Sci Technol; 2013 Nov; 7(6):1484-91. PubMed ID: 24351174 [TBL] [Abstract][Full Text] [Related]
29. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013. Pleus S; Baumstark A; Rittmeyer D; Jendrike N; Haug C; Freckmann G Curr Med Res Opin; 2016 May; 32(5):847-55. PubMed ID: 26809001 [TBL] [Abstract][Full Text] [Related]
30. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. Kovatchev BP; Clarke WL; Breton M; Brayman K; McCall A Diabetes Technol Ther; 2005 Dec; 7(6):849-62. PubMed ID: 16386091 [TBL] [Abstract][Full Text] [Related]
32. Investigation on the accuracy of the blood glucose monitoring device Prestige IQ. Larbig M; Forst T; Mondok A; Forst S; Pfützner A Diabetes Nutr Metab; 2003 Aug; 16(4):257-61. PubMed ID: 14768776 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes. Littmann K; Petersen ER; Pussinen C; Danielson K; Djurisic S; Eilertsen H; Garabet L; Greibe E; Lauritzen T; Olsen DA; Othman S; Palimaru I; Westerlund J Scand J Clin Lab Invest; 2013; 73(4):286-92. PubMed ID: 23473019 [TBL] [Abstract][Full Text] [Related]
34. Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems. Garg SK; Smith J; Beatson C; Lopez-Baca B; Voelmle M; Gottlieb PA Diabetes Technol Ther; 2009 Feb; 11(2):65-72. PubMed ID: 19243265 [TBL] [Abstract][Full Text] [Related]
35. A Comprehensive Performance Evaluation of Five Blood Glucose Systems in the Hypo-, Eu-, and Hyperglycemic Range. Zijlstra E; Heinemann L; Fischer A; Kapitza C J Diabetes Sci Technol; 2016 Nov; 10(6):1316-1323. PubMed ID: 27605592 [TBL] [Abstract][Full Text] [Related]
36. Evaluation of a new blood glucose monitoring system with auto-calibration. Kilo C; Pinson M; Joynes JO; Joseph H; Monhaut N; Parkes JL; Baum J Diabetes Technol Ther; 2005 Apr; 7(2):283-94. PubMed ID: 15857230 [TBL] [Abstract][Full Text] [Related]
37. A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic. Thomas LE; Kane MP; Bakst G; Busch RS; Hamilton RA; Abelseth JM Diabetes Technol Ther; 2008 Apr; 10(2):102-10. PubMed ID: 18260773 [TBL] [Abstract][Full Text] [Related]
38. Accuracy and precision of glucose monitoring are relevant to treatment decision-making and clinical outcome in hospitalized patients with diabetes. Voulgari C; Tentolouris N Diabetes Technol Ther; 2011 Jul; 13(7):723-30. PubMed ID: 21699417 [TBL] [Abstract][Full Text] [Related]
39. Accuracy Evaluation of a Blood Glucose Monitoring System According to EN ISO 15197:2015. Bright D; Dunseath G; Berti F; Scuffi C; Valgimigli F; Luzio S J Diabetes Sci Technol; 2017 Jul; 11(4):849-850. PubMed ID: 28745087 [No Abstract] [Full Text] [Related]
40. Retrofitting of continuous glucose monitoring traces allows more accurate assessment of glucose control in outpatient studies. Del Favero S; Facchinetti A; Sparacino G; Cobelli C; Diabetes Technol Ther; 2015 May; 17(5):355-63. PubMed ID: 25671379 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]