These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
629 related articles for article (PubMed ID: 20152447)
1. SiO2 coated Fe3O4 magnetic nanoparticle dispersed multiwalled carbon nanotubes based amperometric glucose biosensor. Baby TT; Ramaprabhu S Talanta; 2010 Mar; 80(5):2016-22. PubMed ID: 20152447 [TBL] [Abstract][Full Text] [Related]
2. A glucose biosensor based on deposition of glucose oxidase onto crystalline gold nanoparticle modified carbon nanotube electrode. Rakhi RB; Sethupathi K; Ramaprabhu S J Phys Chem B; 2009 Mar; 113(10):3190-4. PubMed ID: 19260716 [TBL] [Abstract][Full Text] [Related]
3. Magnetic core-shell Fe₃O₄@SiO₂/MWCNT nanocomposite modified carbon paste electrode for amplified electrochemical sensing of uric acid. Arvand M; Hassannezhad M Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():160-7. PubMed ID: 24433899 [TBL] [Abstract][Full Text] [Related]
4. Synthesis of functional SiO₂-coated graphene oxide nanosheets decorated with Ag nanoparticles for H₂O₂ and glucose detection. Lu W; Luo Y; Chang G; Sun X Biosens Bioelectron; 2011 Aug; 26(12):4791-7. PubMed ID: 21733668 [TBL] [Abstract][Full Text] [Related]
5. Glucose biosensor based on electrodeposition of platinum nanoparticles onto carbon nanotubes and immobilizing enzyme with chitosan-SiO(2) sol-gel. Zou Y; Xiang C; Sun LX; Xu F Biosens Bioelectron; 2008 Feb; 23(7):1010-6. PubMed ID: 18054479 [TBL] [Abstract][Full Text] [Related]
6. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes. Kang X; Mai Z; Zou X; Cai P; Mo J Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866 [TBL] [Abstract][Full Text] [Related]
7. Amperometric glucose biosensor based on glucose oxidase dispersed in multiwalled carbon nanotubes/graphene oxide hybrid biocomposite. Palanisamy S; Cheemalapati S; Chen SM Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():207-13. PubMed ID: 24268251 [TBL] [Abstract][Full Text] [Related]
8. An electrochemical sensor for rizatriptan benzoate determination using Fe3O4 nanoparticle/multiwall carbon nanotube-modified glassy carbon electrode in real samples. Madrakian T; Maleki S; Heidari M; Afkhami A Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():637-43. PubMed ID: 27040259 [TBL] [Abstract][Full Text] [Related]
9. Development of Au nanoparticles dispersed carbon nanotube-based biosensor for the detection of paraoxon. Jha N; Ramaprabhu S Nanoscale; 2010 May; 2(5):806-10. PubMed ID: 20648328 [TBL] [Abstract][Full Text] [Related]
10. In situ chemo-synthesized multi-wall carbon nanotube-conductive polyaniline nanocomposites: characterization and application for a glucose amperometric biosensor. Zhong H; Yuan R; Chai Y; Li W; Zhong X; Zhang Y Talanta; 2011 Jul; 85(1):104-11. PubMed ID: 21645677 [TBL] [Abstract][Full Text] [Related]
11. Cast thin film biosensor design based on a Nafion backbone, a multiwalled carbon nanotube conduit, and a glucose oxidase function. Tsai YC; Li SC; Chen JM Langmuir; 2005 Apr; 21(8):3653-8. PubMed ID: 15807616 [TBL] [Abstract][Full Text] [Related]
13. A novel nanobiocomposite based glucose biosensor using neutral red functionalized carbon nanotubes. Shobha Jeykumari DR; Sriman Narayanan S Biosens Bioelectron; 2008 Apr; 23(9):1404-11. PubMed ID: 18294834 [TBL] [Abstract][Full Text] [Related]
14. Preparation of multiwalled carbon nanotubes-platinum-Nafion-glucose oxidase nanobiocomposite and its application to glucose biosensor. Tsai YC; Chien HY J Nanosci Nanotechnol; 2007; 7(4-5):1611-7. PubMed ID: 17450933 [TBL] [Abstract][Full Text] [Related]
15. Bimetallic PtM (M=Pd, Ir) nanoparticle decorated multi-walled carbon nanotube enzyme-free, mediator-less amperometric sensor for H₂O₂. Chen KJ; Chandrasekara Pillai K; Rick J; Pan CJ; Wang SH; Liu CC; Hwang BJ Biosens Bioelectron; 2012 Mar; 33(1):120-7. PubMed ID: 22236778 [TBL] [Abstract][Full Text] [Related]
16. Preparation and characterization of bismuth oxide nanoparticles-multiwalled carbon nanotube composite for the development of horseradish peroxidase based H₂O₂ biosensor. Periasamy AP; Yang S; Chen SM Talanta; 2011 Dec; 87():15-23. PubMed ID: 22099642 [TBL] [Abstract][Full Text] [Related]
17. Nanocomposite based on depositing platinum nanostructure onto carbon nanotubes through a one-pot, facile synthesis method for amperometric sensing. Wen D; Zou X; Liu Y; Shang L; Dong S Talanta; 2009 Oct; 79(5):1233-7. PubMed ID: 19635352 [TBL] [Abstract][Full Text] [Related]
18. Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide--multiwalled carbon nanotube film modified glass carbon electrode. Gao W; Tjiu WW; Wei J; Liu T Talanta; 2014 Mar; 120():484-90. PubMed ID: 24468400 [TBL] [Abstract][Full Text] [Related]
19. Fabrication of bienzyme nanobiocomposite electrode using functionalized carbon nanotubes for biosensing applications. Jeykumari DR; Narayanan SS Biosens Bioelectron; 2008 Jun; 23(11):1686-93. PubMed ID: 18343650 [TBL] [Abstract][Full Text] [Related]
20. Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose. Qiu JD; Zhou WM; Guo J; Wang R; Liang RP Anal Biochem; 2009 Feb; 385(2):264-9. PubMed ID: 19100707 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]