BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 20166238)

  • 1. Minimisation of the wall shear stress gradients in bypass grafts anastomoses using meshless CFD and genetic algorithms optimisation.
    El Zahab Z; Divo E; Kassab A
    Comput Methods Biomech Biomed Engin; 2010 Feb; 13(1):35-47. PubMed ID: 20166238
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational design of a bypass graft that minimizes wall shear stress gradients in the region of the distal anastomosis.
    Lei M; Archie JP; Kleinstreuer C
    J Vasc Surg; 1997 Apr; 25(4):637-46. PubMed ID: 9129618
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the hemodynamics in 6mm and 4-7 mm hemodialysis grafts by means of CFD.
    Van Tricht I; De Wachter D; Tordoir J; Verdonck P
    J Biomech; 2006; 39(2):226-36. PubMed ID: 16321624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation of flow through a Miller cuff bypass graft.
    Henry FS; Küpper C; Lewington NP
    Comput Methods Biomech Biomed Engin; 2002 Jun; 5(3):207-17. PubMed ID: 12186713
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Numerical simulation of wall shear stress and particle-based hemodynamic parameters in pre-cuffed and streamlined end-to-side anastomoses.
    Longest PW; Kleinstreuer C; Deanda A
    Ann Biomed Eng; 2005 Dec; 33(12):1752-66. PubMed ID: 16389524
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review.
    Haruguchi H; Teraoka S
    J Artif Organs; 2003; 6(4):227-35. PubMed ID: 14691664
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interposition vein cuff anastomosis alters wall shear stress distribution in the recipient artery.
    How TV; Rowe CS; Gilling-Smith GL; Harris PL
    J Vasc Surg; 2000 May; 31(5):1008-17. PubMed ID: 10805893
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Geometric design improvements for femoral graft-artery junctions mitigating restenosis.
    Lei M; Kleinstreuer C; Archie JP
    J Biomech; 1996 Dec; 29(12):1605-14. PubMed ID: 8945659
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Altering end-to-side anastomosis junction hemodynamics: the effects of flow-splitting.
    O'Brien T; Walsh M; McGloughlin T
    Med Eng Phys; 2006 Sep; 28(7):727-33. PubMed ID: 16337824
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of numerical simulation with PIV measurements for two anastomosis models.
    Zhang JM; Chua LP; Ghista DN; Zhou TM; Tan YS
    Med Eng Phys; 2008 Mar; 30(2):226-47. PubMed ID: 17466565
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A parametric numerical investigation on haemodynamics in distal coronary anastomoses.
    Xiong FL; Chong CK
    Med Eng Phys; 2008 Apr; 30(3):311-20. PubMed ID: 17616426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the existence of an optimum end-to-side junctional geometry in peripheral bypass surgery--a computer generated study.
    Walsh MT; Kavanagh EG; O'Brien T; Grace PA; McGloughlin T
    Eur J Vasc Endovasc Surg; 2003 Dec; 26(6):649-56. PubMed ID: 14603426
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rheological effects of blood in a nonplanar distal end-to-side anastomosis.
    Wang QQ; Ping BH; Xu QB; Wang W
    J Biomech Eng; 2008 Oct; 130(5):051009. PubMed ID: 19045516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of proximal artery flow on the hemodynamics at the distal anastomosis of a vascular bypass graft: computational study.
    Kute SM; Vorp DA
    J Biomech Eng; 2001 Jun; 123(3):277-83. PubMed ID: 11476372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-Newtonian effects of blood flow on hemodynamics in distal vascular graft anastomoses.
    Chen J; Lu XY; Wang W
    J Biomech; 2006; 39(11):1983-95. PubMed ID: 16055134
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical study of the influence of anastomotic configuration on hemodynamics in miller cuff models.
    Xiong FL; Chong CK
    Ann Biomed Eng; 2009 Feb; 37(2):301-14. PubMed ID: 19082894
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An S-type bypass can improve the hemodynamics in the bypassed arteries and suppress intimal hyperplasia along the host artery floor.
    Fan Y; Xu Z; Jiang W; Deng X; Wang K; Sun A
    J Biomech; 2008 Aug; 41(11):2498-505. PubMed ID: 18573497
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Swirling flow pattern in a non-planar model of an interposition vein cuff anastomosis.
    How TV; Fisher RK; Brennan JA; Harris PL
    Med Eng Phys; 2006 Jan; 28(1):27-35. PubMed ID: 15921948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PIV-validated numerical modeling of pulsatile flows in distal coronary end-to-side anastomoses.
    Xiong FL; Chong CK
    J Biomech; 2007; 40(13):2872-81. PubMed ID: 17466995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow waveform effects on end-to-side anastomotic flow patterns.
    Ethier CR; Steinman DA; Zhang X; Karpik SR; Ojha M
    J Biomech; 1998 Jul; 31(7):609-17. PubMed ID: 9796683
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.