BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 20167503)

  • 1. True coincidence-summing corrections for the coincident gamma-rays measured with coplanar grid CdZnTe detectors.
    Yücel H; Solmaz AN; Köse E; Bor D
    Appl Radiat Isot; 2010 Jun; 68(6):1040-8. PubMed ID: 20167503
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Methods for spectral interference corrections for direct measurements of 234U and 230Th in materials by gamma-ray spectrometry.
    Yücel H; Solmaz AN; Köse E; Bor D
    Radiat Prot Dosimetry; 2010 Mar; 138(3):264-77. PubMed ID: 19843544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical expressions for the computation of coincidence-summing correction factors in gamma-ray spectrometry with HPGe detectors.
    Rizzo S; Tomarchio E
    Appl Radiat Isot; 2010; 68(4-5):555-60. PubMed ID: 19892555
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Close-geometry efficiency calibration of p-type HPGe detectors with a Cs-134 point source.
    DeFelice P; Fazio A; Vidmar T; Korun M
    Appl Radiat Isot; 2006; 64(10-11):1303-6. PubMed ID: 16549352
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental assessment of the coincidence summing corrections in gamma-ray spectrometry of bulk samples.
    Boshkova T
    Appl Radiat Isot; 2014 Jan; 83 Pt A():1-7. PubMed ID: 24212138
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction methodology for the spectral interfering γ-rays overlapping to the analytical peaks used in the analysis of 232Th.
    Yücel H; Köse E; Esen AN; Bor D
    Appl Radiat Isot; 2011 Jun; 69(6):890-7. PubMed ID: 21398134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A method for calculation of true coincidence summing correction factors for extended sources.
    Vidmar T; Korun M; Vodenik B
    Appl Radiat Isot; 2007 Feb; 65(2):243-6. PubMed ID: 16987667
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurements on the spectroscopic performance of CdZnTe coplanar grid detectors.
    Yücel H; Uyar E; Esen AN
    Appl Radiat Isot; 2012 Aug; 70(8):1608-15. PubMed ID: 22738836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Precise measurement and calculation of coincidence summing corrections for point and linear sources.
    Sima O; Arnold D
    Appl Radiat Isot; 2012 Sep; 70(9):2107-11. PubMed ID: 22405956
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calculation of true coincidence summing corrections for extended sources with EFFTRAN.
    Vidmar T; Kanisch G; Vidmar G
    Appl Radiat Isot; 2011 Jun; 69(6):908-11. PubMed ID: 21397512
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration of cylindrical detectors using a simplified theoretical approach.
    Abbas MI; Nafee S; Selim YS
    Appl Radiat Isot; 2006 Sep; 64(9):1057-64. PubMed ID: 16814553
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Testing the equivalence of several algorithms for calculation of coincidence summing corrections.
    Kanisch G; Vidmar T; Sima O
    Appl Radiat Isot; 2009 Oct; 67(10):1952-6. PubMed ID: 19647443
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental validation of coincidence summing corrections computed by the ETNA software.
    Lépy MC; Brun P; Collin C; Plagnard J
    Appl Radiat Isot; 2006; 64(10-11):1340-5. PubMed ID: 16600602
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the iteration of coincidence summing correction for determination of gamma-ray intensities.
    Shima Y; Hayashi H; Kojima Y; Jyousyou R; Shibata M
    Appl Radiat Isot; 2016 Mar; 109():535-538. PubMed ID: 26620847
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of GESPECOR software for the calculation of coincidence summing effects in special cases.
    Arnold D; Sima O
    Appl Radiat Isot; 2004; 60(2-4):167-72. PubMed ID: 14987637
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simplified methods for coincidence summing corrections in HPGe efficiency calibration.
    Mauring A; Drefvelin J
    Appl Radiat Isot; 2012 Sep; 70(9):2161-3. PubMed ID: 22429555
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spectral interference corrections for the measurement of (238)U in materials rich in thorium by a high resolution gamma-ray spectrometry.
    Yücel H; Solmaz AN; Köse E; Bor D
    Appl Radiat Isot; 2009 Nov; 67(11):2049-56. PubMed ID: 19683454
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coincidence summing corrections applied to volume sources.
    Lépy MC; Ferreux L; Pierre S
    Appl Radiat Isot; 2012 Sep; 70(9):2137-40. PubMed ID: 22410298
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of CdZnTe as neutron detector around medical accelerators.
    Martín-Martín A; Iñiguez MP; Luke PN; Barquero R; Lorente A; Morchón J; Gallego E; Quincoces G; Martí-Climent JM
    Radiat Prot Dosimetry; 2009 Feb; 133(4):193-9. PubMed ID: 19329512
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correction of coincidence summing effects for add-back mode measurements with a 4π clover detector using experimental total efficiency.
    Yamashita T; Kamada H; Kojima Y; Shibata M
    Appl Radiat Isot; 2018 May; 135():131-134. PubMed ID: 29413827
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.