These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 20169107)

  • 1. Realistic and spherical head modeling for EEG forward problem solution: a comparative cortex-based analysis.
    Vatta F; Meneghini F; Esposito F; Mininel S; Di Salle F
    Comput Intell Neurosci; 2010; 2010():972060. PubMed ID: 20169107
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Solving the forward problem in EEG source analysis by spherical and fdm head modeling: a comparative analysis - biomed 2009.
    Vatta F; Meneghini F; Esposito F; Mininel S; Di Salle F
    Biomed Sci Instrum; 2009; 45():382-8. PubMed ID: 19369793
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of realistic head modeling methods in EEG source imaging - biomed 2010.
    Vatta F; Meneghini F; Esposito F; Mininel S; Disalle F
    Biomed Sci Instrum; 2010; 46():398-403. PubMed ID: 20467114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between realistic and spherical approaches in EEG forward modelling.
    Meneghini F; Vatta F; Esposito F; Mininel S; Di Salle F
    Biomed Tech (Berl); 2010 Jun; 55(3):133-46. PubMed ID: 20178450
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of volume conductor and source models to localize epileptic foci.
    Fuchs M; Wagner M; Kastner J
    J Clin Neurophysiol; 2007 Apr; 24(2):101-19. PubMed ID: 17414966
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low resolution brain electromagnetic tomography in a realistic geometry head model: a simulation study.
    Ding L; Lai Y; He B
    Phys Med Biol; 2005 Jan; 50(1):45-56. PubMed ID: 15715421
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using reciprocity for relating the simulation of transcranial current stimulation to the EEG forward problem.
    Wagner S; Lucka F; Vorwerk J; Herrmann CS; Nolte G; Burger M; Wolters CH
    Neuroimage; 2016 Oct; 140():163-73. PubMed ID: 27125841
    [TBL] [Abstract][Full Text] [Related]  

  • 8. EEG and MEG: forward solutions for inverse methods.
    Mosher JC; Leahy RM; Lewis PS
    IEEE Trans Biomed Eng; 1999 Mar; 46(3):245-59. PubMed ID: 10097460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Approximate average head models for EEG source imaging.
    Valdés-Hernández PA; von Ellenrieder N; Ojeda-Gonzalez A; Kochen S; Alemán-Gómez Y; Muravchik C; Valdés-Sosa PA
    J Neurosci Methods; 2009 Dec; 185(1):125-32. PubMed ID: 19747944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of fMRI-EEG mismatches in cortical current density estimation integrating fMRI and EEG: a simulation study.
    Liu Z; Kecman F; He B
    Clin Neurophysiol; 2006 Jul; 117(7):1610-22. PubMed ID: 16765085
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved surface Laplacian estimates of cortical potential using realistic models of head geometry.
    Deng S; Winter W; Thorpe S; Srinivasan R
    IEEE Trans Biomed Eng; 2012 Nov; 59(11):2979-85. PubMed ID: 22249595
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of blood vessels in high-resolution volume conductor head modeling of EEG.
    Fiederer LDJ; Vorwerk J; Lucka F; Dannhauer M; Yang S; Dümpelmann M; Schulze-Bonhage A; Aertsen A; Speck O; Wolters CH; Ball T
    Neuroimage; 2016 Mar; 128():193-208. PubMed ID: 26747748
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Data-driven forward model inference for EEG brain imaging.
    Hansen ST; Hauberg S; Hansen LK
    Neuroimage; 2016 Oct; 139():249-258. PubMed ID: 27307192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Consistency of EEG source localization and connectivity estimates.
    Mahjoory K; Nikulin VV; Botrel L; Linkenkaer-Hansen K; Fato MM; Haufe S
    Neuroimage; 2017 May; 152():590-601. PubMed ID: 28300640
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of holes on EEG forward solutions using a realistic geometry head model.
    Li J; Wang K; Zhu S; He B
    J Neural Eng; 2007 Sep; 4(3):197-204. PubMed ID: 17873421
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A realistic, accurate and fast source modeling approach for the EEG forward problem.
    Miinalainen T; Rezaei A; Us D; Nüßing A; Engwer C; Wolters CH; Pursiainen S
    Neuroimage; 2019 Jan; 184():56-67. PubMed ID: 30165251
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution. A high-resolution whole head simulation study.
    Güllmar D; Haueisen J; Reichenbach JR
    Neuroimage; 2010 May; 51(1):145-63. PubMed ID: 20156576
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bayesian model selection of template forward models for EEG source reconstruction.
    Strobbe G; van Mierlo P; De Vos M; Mijović B; Hallez H; Van Huffel S; López JD; Vandenberghe S
    Neuroimage; 2014 Jun; 93 Pt 1():11-22. PubMed ID: 24582919
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bioelectromagnetic forward problem: isolated source approach revis(it)ed.
    Stenroos M; Sarvas J
    Phys Med Biol; 2012 Jun; 57(11):3517-35. PubMed ID: 22581305
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapidly recomputable EEG forward models for realistic head shapes.
    Ermer JJ; Mosher JC; Baillet S; Leah RM
    Phys Med Biol; 2001 Apr; 46(4):1265-81. PubMed ID: 11324964
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.