425 related articles for article (PubMed ID: 20175465)
1. Photon beam quality variations of a flattening filter free linear accelerator.
Georg D; Kragl G; Wetterstedt Sa; McCavana P; McClean B; Knöös T
Med Phys; 2010 Jan; 37(1):49-53. PubMed ID: 20175465
[TBL] [Abstract][Full Text] [Related]
2. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
Tyner E; McClean B; McCavana P; af Wetterstedt S
Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
[TBL] [Abstract][Full Text] [Related]
3. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
[TBL] [Abstract][Full Text] [Related]
4. Beam characteristics of energy-matched flattening filter free beams.
Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
[TBL] [Abstract][Full Text] [Related]
5. A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams.
Richmond N; Allen V; Daniel J; Dacey R; Walker C
Med Dosim; 2015; 40(1):58-63. PubMed ID: 25454113
[TBL] [Abstract][Full Text] [Related]
6. Impact of a flattening filter free linear accelerator on structural shielding design.
Jank J; Kragl G; Georg D
Z Med Phys; 2014 Mar; 24(1):38-48. PubMed ID: 23763984
[TBL] [Abstract][Full Text] [Related]
7. Technical Note: On the impact of the incident electron beam energy on the primary dose component of flattening filter free photon beams.
Kuess P; Georg D; Palmans H; Lechner W
Med Phys; 2016 Aug; 43(8):4507. PubMed ID: 27487867
[TBL] [Abstract][Full Text] [Related]
8. Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams.
Cashmore J
J Appl Clin Med Phys; 2016 Sep; 17(5):293-307. PubMed ID: 27685127
[TBL] [Abstract][Full Text] [Related]
9. Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator.
Soriani A; Felici G; Fantini M; Paolucci M; Borla O; Evangelisti G; Benassi M; Strigari L
Med Phys; 2010 Mar; 37(3):995-1003. PubMed ID: 20384235
[TBL] [Abstract][Full Text] [Related]
10. [Measurement of peak correction factor of Farmer chamber for calibration of flattening filter free (FFF) clinical photon beams].
Kontra G; Major T; Polgár C
Magy Onkol; 2015 Jun; 59(2):119-23. PubMed ID: 26035159
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric characteristics of 6 and 10MV unflattened photon beams.
Kragl G; af Wetterstedt S; Knäusl B; Lind M; McCavana P; Knöös T; McClean B; Georg D
Radiother Oncol; 2009 Oct; 93(1):141-6. PubMed ID: 19592123
[TBL] [Abstract][Full Text] [Related]
12. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.
Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G
Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
Almberg SS; Frengen J; Lindmo T
Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
[TBL] [Abstract][Full Text] [Related]
14. Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator.
Mesbahi A; Nejad FS
Radiat Med; 2008 Jul; 26(6):331-6. PubMed ID: 18677606
[TBL] [Abstract][Full Text] [Related]
15. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
Dalaryd M; Knöös T; Ceberg C
Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
[TBL] [Abstract][Full Text] [Related]
16. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
[TBL] [Abstract][Full Text] [Related]
17. Comparison of measured and Monte Carlo calculated dose distributions from the NRC linac.
Sheikh-Bagheri D; Rogers DW; Ross CK; Seuntjens JP
Med Phys; 2000 Oct; 27(10):2256-66. PubMed ID: 11099192
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator.
Meshram MN; Pramanik S; Ranjith CP; Gopal SK; Dobhal R
J Appl Clin Med Phys; 2016 May; 17(3):358-370. PubMed ID: 27167293
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.
Mesbahi A
Appl Radiat Isot; 2007 Sep; 65(9):1029-36. PubMed ID: 17616465
[TBL] [Abstract][Full Text] [Related]
20. Characteristics of flattening filter free beams at low monitor unit settings.
Akino Y; Ota S; Inoue S; Mizuno H; Sumida I; Yoshioka Y; Isohashi F; Ogawa K
Med Phys; 2013 Nov; 40(11):112101. PubMed ID: 24320454
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]