BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

400 related articles for article (PubMed ID: 20182251)

  • 1. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
    Lujan TJ; Henderson CE; Madey SM; Fitzpatrick DC; Marsh JL; Bottlang M
    J Orthop Trauma; 2010 Mar; 24(3):156-62. PubMed ID: 20182251
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.
    Krieg JC
    J Orthop Trauma; 2011 Feb; 25(2):e21; author reply e21-2. PubMed ID: 21245704
    [No Abstract]   [Full Text] [Related]  

  • 3. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
    Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Far cortical locking can improve healing of fractures stabilized with locking plates.
    Bottlang M; Lesser M; Koerber J; Doornink J; von Rechenberg B; Augat P; Fitzpatrick DC; Madey SM; Marsh JL
    J Bone Joint Surg Am; 2010 Jul; 92(7):1652-60. PubMed ID: 20595573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Motion Predicts Clinical Callus Formation: Construct-Specific Finite Element Analysis of Supracondylar Femoral Fractures.
    Elkins J; Marsh JL; Lujan T; Peindl R; Kellam J; Anderson DD; Lack W
    J Bone Joint Surg Am; 2016 Feb; 98(4):276-84. PubMed ID: 26888675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stabilization of distal femur fractures with intramedullary nails and locking plates: differences in callus formation.
    Henderson CE; Lujan T; Bottlang M; Fitzpatrick DC; Madey SM; Marsh JL
    Iowa Orthop J; 2010; 30():61-8. PubMed ID: 21045973
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination of interfragmentary screws and locking plates in distal meta-diaphyseal fractures of the tibia: a retrospective, single-centre pilot study.
    Horn C; Döbele S; Vester H; Schäffler A; Lucke M; Stöckle U
    Injury; 2011 Oct; 42(10):1031-7. PubMed ID: 21663909
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation.
    Byun SE; Vintimilla DR; Bedeir YH; Dean CS; Parry JA; Hak DJ; Mauffrey C
    Eur J Orthop Surg Traumatol; 2020 Aug; 30(6):1103-1107. PubMed ID: 32356122
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.
    Henderson CE; Bottlang M; Marsh JL; Fitzpatrick DC; Madey SM
    Iowa Orthop J; 2008; 28():73-6. PubMed ID: 19223952
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Any Cortical Bridging Predicts Healing of Supracondylar Femur Fractures After Treatment With Locked Plating.
    Strotman PK; Karunakar MA; Seymour R; Lack WD
    J Orthop Trauma; 2017 Oct; 31(10):538-544. PubMed ID: 28538286
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Working length and proximal screw constructs in plate osteosynthesis of distal femur fractures.
    Harvin WH; Oladeji LO; Della Rocca GJ; Murtha YM; Volgas DA; Stannard JP; Crist BD
    Injury; 2017 Nov; 48(11):2597-2601. PubMed ID: 28889934
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictive factors of distal femoral fracture nonunion after lateral locked plating: a retrospective multicenter case-control study of 283 fractures.
    Rodriguez EK; Boulton C; Weaver MJ; Herder LM; Morgan JH; Chacko AT; Appleton PT; Zurakowski D; Vrahas MS
    Injury; 2014 Mar; 45(3):554-9. PubMed ID: 24275357
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Healing results of periprosthetic distal femur fractures treated with far cortical locking technology: a preliminary retrospective study.
    Ries Z; Hansen K; Bottlang M; Madey S; Fitzpatrick D; Marsh JL
    Iowa Orthop J; 2013; 33():7-11. PubMed ID: 24027454
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
    Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
    J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic Locked Plating of Distal Femur Fractures.
    Linn MS; McAndrew CM; Prusaczyk B; Brimmo O; Ricci WM; Gardner MJ
    J Orthop Trauma; 2015 Oct; 29(10):447-50. PubMed ID: 25714439
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures.
    Henderson CE; Lujan TJ; Kuhl LL; Bottlang M; Fitzpatrick DC; Marsh JL
    Clin Orthop Relat Res; 2011 Jun; 469(6):1757-65. PubMed ID: 21424831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic Fixation of Humeral Shaft Fractures Using Active Locking Plates: A Prospective Observational Study.
    Madey SM; Tsai S; Fitzpatrick DC; Earley K; Lutsch M; Bottlang M
    Iowa Orthop J; 2017; 37():1-10. PubMed ID: 28852327
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic fixation of distal femur fractures using far cortical locking screws: a prospective observational study.
    Bottlang M; Fitzpatrick DC; Sheerin D; Kubiak E; Gellman R; Vande Zandschulp C; Doornink J; Earley K; Madey SM
    J Orthop Trauma; 2014 Apr; 28(4):181-8. PubMed ID: 24231583
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiographic Healing of Far Cortical Locking Constructs in Distal Femur Fractures: A Comparative Study With Standard Locking Plates.
    Plumarom Y; Wilkinson BG; Marsh JL; Willey MC; An Q; Gao Y; Karam MD
    J Orthop Trauma; 2019 Jun; 33(6):277-283. PubMed ID: 30908342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.