BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

378 related articles for article (PubMed ID: 20186630)

  • 1. [Multidetector-row CT evaluation of acute bowel ischemia induced by embolization of superior mesenteric artery in experimental porcine models].
    Qiang JW; Li RK; Feng XY; Liao ZH; He C; Feng Q; Zhang B; Ye XG
    Zhonghua Wei Chang Wai Ke Za Zhi; 2010 Feb; 13(2):151-5. PubMed ID: 20186630
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acute mesenteric ischemia induced by ligation of porcine superior mesenteric vein: multidetector CT evaluations.
    Tang ZH; Qiang JW; Feng XY; Li RK; Sun RX; Ye XG
    Acad Radiol; 2010 Sep; 17(9):1146-52. PubMed ID: 20646939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.
    Rosow DE; Sahani D; Strobel O; Kalva S; Mino-Kenudson M; Holalkere NS; Alsfasser G; Saini S; Lee SI; Mueller PR; Fernández-del Castillo C; Warshaw AL; Thayer SP
    J Gastrointest Surg; 2005 Dec; 9(9):1262-74; discussion 1274-5. PubMed ID: 16332482
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biphasic CT with mesenteric CT angiography in the evaluation of acute mesenteric ischemia: initial experience.
    Kirkpatrick ID; Kroeker MA; Greenberg HM
    Radiology; 2003 Oct; 229(1):91-8. PubMed ID: 12944600
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CT and MRI of experimentally induced mesenteric ischemia in a porcine model.
    Klein HM; Klosterhalfen B; Kinzel S; Jansen A; Seggewiss C; Weghaus P; Kamp M; Töns C; Günther RW
    J Comput Assist Tomogr; 1996; 20(2):254-61. PubMed ID: 8606233
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volume-rendered 3D CT of the mesenteric vasculature: normal anatomy, anatomic variants, and pathologic conditions.
    Horton KM; Fishman EK
    Radiographics; 2002; 22(1):161-72. PubMed ID: 11796905
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Ischemic and Nonischemic Bowel Segments in Patients With Mesenteric Ischemia: Multidetector Row Computed Tomography Findings and Measurement of Bowel Wall Attenuation Changes.
    Chen YC; Huang TY; Chen RC; Tsai SH; Chang WC; Fan HL; Huang GS; Ko KH; Chou YC; Hsu HH
    Mayo Clin Proc; 2016 Mar; 91(3):316-28. PubMed ID: 26809547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of acute mesenteric ischemia: accuracy of biphasic mesenteric multi-detector CT angiography.
    Aschoff AJ; Stuber G; Becker BW; Hoffmann MH; Schmitz BL; Schelzig H; Jaeckle T
    Abdom Imaging; 2009; 34(3):345-57. PubMed ID: 18425546
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental study on acute ischemic small bowel changes induced by superselective embolization of superior mesenteric artery branches with N-butyl cyanoacrylate.
    Jae HJ; Chung JW; Kim HC; So YH; Lim HG; Lee W; Kim BK; Park JH
    J Vasc Interv Radiol; 2008 May; 19(5):755-63. PubMed ID: 18440466
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT in acute mesenteric ischaemia.
    Lee R; Tung HK; Tung PH; Cheung SC; Chan FL
    Clin Radiol; 2003 Apr; 58(4):279-87. PubMed ID: 12662948
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Role of multidetector CT angiography in the evaluation of suspected mesenteric ischemia.
    Barmase M; Kang M; Wig J; Kochhar R; Gupta R; Khandelwal N
    Eur J Radiol; 2011 Dec; 80(3):e582-7. PubMed ID: 21993179
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CT angiography of the mesenteric circulation.
    Horton KM; Fishman EK
    Radiol Clin North Am; 2010 Mar; 48(2):331-45, viii. PubMed ID: 20609877
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Assessment of acute mesenteric ischemia with multi-slice spiral CT].
    Chen M; Li X; Xie JX
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2006 Feb; 28(1):80-3. PubMed ID: 16548196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of experimental embolization of superior mesenteric artery branch on the intestine.
    Cho KJ; Schmidt RW; Lenz J
    Invest Radiol; 1979; 14(3):207-12. PubMed ID: 468491
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multidetector CT angiography in the evaluation of acute mesenteric ischemia.
    Ofer A; Abadi S; Nitecki S; Karram T; Kogan I; Leiderman M; Shmulevsky P; Israelit S; Engel A
    Eur Radiol; 2009 Jan; 19(1):24-30. PubMed ID: 18690454
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Establishment of canine models of acute mesenteric ischamia].
    Yang B; Quan XY; Yu ZJ; Yang JC; Long QJ
    Di Yi Jun Yi Da Xue Xue Bao; 2004 Jun; 24(6):703-5. PubMed ID: 15201096
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CT diagnosis of acute mesenteric ischemia from various causes.
    Furukawa A; Kanasaki S; Kono N; Wakamiya M; Tanaka T; Takahashi M; Murata K
    AJR Am J Roentgenol; 2009 Feb; 192(2):408-16. PubMed ID: 19155403
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images.
    Woodhams R; Nishimaki H; Fujii K; Kakita S; Hayakawa K
    Eur J Radiol; 2010 Oct; 76(1):96-102. PubMed ID: 19501999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multidetector row computed tomography findings from ischemia to infarction of the large bowel.
    Romano S; Romano L; Grassi R
    Eur J Radiol; 2007 Mar; 61(3):433-41. PubMed ID: 17157468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Acute bowel ischemia: CT findings.
    Angelelli G; Scardapane A; Memeo M; Stabile Ianora AA; Rotondo A
    Eur J Radiol; 2004 Apr; 50(1):37-47. PubMed ID: 15093234
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.