These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 20192498)

  • 1. A low noise all-fiber interferometer for high resolution frequency modulated atomic force microscopy imaging in liquids.
    Rasool HI; Wilkinson PR; Stieg AZ; Gimzewski JK
    Rev Sci Instrum; 2010 Feb; 81(2):023703. PubMed ID: 20192498
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy.
    Fukuma T
    Rev Sci Instrum; 2009 Feb; 80(2):023707. PubMed ID: 19256653
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A high frequency sensor for optical beam deflection atomic force microscopy.
    Enning R; Ziegler D; Nievergelt A; Friedlos R; Venkataramani K; Stemmer A
    Rev Sci Instrum; 2011 Apr; 82(4):043705. PubMed ID: 21529011
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Frequency noise in frequency modulation atomic force microscopy.
    Kobayashi K; Yamada H; Matsushige K
    Rev Sci Instrum; 2009 Apr; 80(4):043708. PubMed ID: 19405667
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modification of a commercial atomic force microscopy for low-noise, high-resolution frequency-modulation imaging in liquid environment.
    Rode S; Stark R; Lübbe J; Tröger L; Schütte J; Umeda K; Kobayashi K; Yamada H; Kühnle A
    Rev Sci Instrum; 2011 Jul; 82(7):073703. PubMed ID: 21806185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wideband digital frequency detector with subtraction-based phase comparator for frequency modulation atomic force microscopy.
    Mitani Y; Kubo M; Muramoto K; Fukuma T
    Rev Sci Instrum; 2009 Aug; 80(8):083705. PubMed ID: 19725660
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Potential of interferometric cantilever detection and its application for SFM/AFM in liquids.
    Hoogenboom BW; Frederix PL; Fotiadis D; Hug HJ; Engel A
    Nanotechnology; 2008 Sep; 19(38):384019. PubMed ID: 21832578
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Atomic force microscopy at ambient and liquid conditions with stiff sensors and small amplitudes.
    Wutscher E; Giessibl FJ
    Rev Sci Instrum; 2011 Sep; 82(9):093703. PubMed ID: 21974590
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A fiber-optic interferometer with subpicometer resolution for dc and low-frequency displacement measurement.
    Smith DT; Pratt JR; Howard LP
    Rev Sci Instrum; 2009 Mar; 80(3):035105. PubMed ID: 19334950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An ultra-low noise optical head for liquid environment atomic force microscopy.
    Schlesinger I; Kuchuk K; Sivan U
    Rev Sci Instrum; 2015 Aug; 86(8):083705. PubMed ID: 26329201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-resolution noncontact atomic force microscopy.
    Pérez R; García R; Schwarz U
    Nanotechnology; 2009 Jul; 20(26):260201. PubMed ID: 19531843
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frequency modulation atomic force microscopy in ambient environments utilizing robust feedback tuning.
    Kilpatrick JI; Gannepalli A; Cleveland JP; Jarvis SP
    Rev Sci Instrum; 2009 Feb; 80(2):023701. PubMed ID: 19256647
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Soft-contact imaging in liquid with frequency-modulation torsion resonance mode atomic force microscopy.
    Yang CW; Hwang IS
    Nanotechnology; 2010 Feb; 21(6):065710. PubMed ID: 20057020
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Small-amplitude dynamic force microscopy using a quartz cantilever with an optical interferometer.
    Morita K; Sugimoto Y; Sasagawa Y; Abe M; Morita S
    Nanotechnology; 2010 Jul; 21(30):305704. PubMed ID: 20603540
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High Q optical fiber tips for NC-AFM in liquid.
    LeDue JM; Lopez-Ayon M; Burke SA; Miyahara Y; Grütter P
    Nanotechnology; 2009 Jul; 20(26):264018. PubMed ID: 19509445
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The qPlus sensor, a powerful core for the atomic force microscope.
    Giessibl FJ
    Rev Sci Instrum; 2019 Jan; 90(1):011101. PubMed ID: 30709191
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quadrature phase interferometer for high resolution force spectroscopy.
    Paolino P; Aguilar Sandoval FA; Bellon L
    Rev Sci Instrum; 2013 Sep; 84(9):095001. PubMed ID: 24089852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of intraocular lens surface properties with atomic force microscopy.
    Lombardo M; De Santo MP; Lombardo G; Barberi R; Serrao S
    J Cataract Refract Surg; 2006 Aug; 32(8):1378-84. PubMed ID: 16863979
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exploiting cantilever curvature for noise reduction in atomic force microscopy.
    Labuda A; Grütter PH
    Rev Sci Instrum; 2011 Jan; 82(1):013704. PubMed ID: 21280834
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Visualizing water molecule distribution by atomic force microscopy.
    Kimura K; Ido S; Oyabu N; Kobayashi K; Hirata Y; Imai T; Yamada H
    J Chem Phys; 2010 May; 132(19):194705. PubMed ID: 20499982
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.