These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
439 related articles for article (PubMed ID: 20194799)
1. Damage to the esophagus after atrial fibrillation ablation: Just the tip of the iceberg? High prevalence of mediastinal changes diagnosed by endosonography. Zellerhoff S; Ullerich H; Lenze F; Meister T; Wasmer K; Mönnig G; Köbe J; Milberg P; Bittner A; Domschke W; Breithardt G; Eckardt L Circ Arrhythm Electrophysiol; 2010 Apr; 3(2):155-9. PubMed ID: 20194799 [TBL] [Abstract][Full Text] [Related]
3. Endoscopic evaluation of the esophagus after catheter ablation of atrial fibrillation using contiguous and optimized radiofrequency applications. Wolf M; El Haddad M; De Wilde V; Phlips T; De Pooter J; Almorad A; Strisciuglio T; Vandekerckhove Y; Tavernier R; Crijns HJ; Knecht S; Duytschaever M Heart Rhythm; 2019 Jul; 16(7):1013-1020. PubMed ID: 30710736 [TBL] [Abstract][Full Text] [Related]
4. Esophageal imaging and strategies for avoiding injury during left atrial ablation for atrial fibrillation. Ren JF; Lin D; Marchlinski FE; Callans DJ; Patel V Heart Rhythm; 2006 Oct; 3(10):1156-61. PubMed ID: 17018343 [TBL] [Abstract][Full Text] [Related]
5. Comparative study of strategies to prevent esophageal and periesophageal injury during atrial fibrillation ablation. de Oliveira BD; Oyama H; Hardy CA; de Melo SL; Pisani CF; Chokr MO; Balbo C; da Costa Darrieux FC; Hachul DT; Chaves DM; de Almeida Artifon EL; Cestari IA; Sakai P; Scanavacca MI J Cardiovasc Electrophysiol; 2020 Apr; 31(4):924-933. PubMed ID: 32108399 [TBL] [Abstract][Full Text] [Related]
6. Esophageal damage during radiofrequency ablation of atrial fibrillation: impact of energy settings, lesion sets, and esophageal visualization. Martinek M; Bencsik G; Aichinger J; Hassanein S; Schoefl R; Kuchinka P; Nesser HJ; Purerfellner H J Cardiovasc Electrophysiol; 2009 Jul; 20(7):726-33. PubMed ID: 19207781 [TBL] [Abstract][Full Text] [Related]
7. Characteristics of Atrial Fibrillation Patients Suffering Esophageal Injury Caused by Ablation for Atrial Fibrillation. Zhang P; Zhang YY; Ye Q; Jiang RH; Liu Q; Ye Y; Wu JG; Sheng X; Fu GS; Cha YM; Jiang CY Sci Rep; 2020 Feb; 10(1):2751. PubMed ID: 32066780 [TBL] [Abstract][Full Text] [Related]
8. Identification of a high-risk population for esophageal injury during radiofrequency catheter ablation of atrial fibrillation: procedural and anatomical considerations. Martinek M; Meyer C; Hassanein S; Aichinger J; Bencsik G; Schoefl R; Boehm G; Nesser HJ; Purerfellner H Heart Rhythm; 2010 Sep; 7(9):1224-30. PubMed ID: 20188859 [TBL] [Abstract][Full Text] [Related]
9. Time-to-isolation-guided cryoballoon ablation reduces oesophageal and mediastinal alterations detected by endoscopic ultrasound: results of the MADE-PVI trial. Cordes F; Ellermann C; Dechering DG; Frommeyer G; Kochhäuser S; Lange PS; Pott C; Lenze F; Schmidt H; Ullerich H; Eckardt L Europace; 2019 Sep; 21(9):1325-1333. PubMed ID: 31143952 [TBL] [Abstract][Full Text] [Related]
10. Temperature monitoring and temperature-driven irrigated radiofrequency energy titration do not prevent thermally induced esophageal lesions in pulmonary vein isolation: A randomized study controlled by esophagoscopy before and after catheter ablation. Grosse Meininghaus D; Blembel K; Waniek C; Kruells-Muench J; Ernst H; Kleemann T; Geller JC Heart Rhythm; 2021 Jun; 18(6):926-934. PubMed ID: 33561587 [TBL] [Abstract][Full Text] [Related]
11. The transesophageal echo probe may contribute to esophageal injury after catheter ablation for paroxysmal atrial fibrillation under general anesthesia: a preliminary observation. Kumar S; Brown G; Sutherland F; Morgan J; Andrews D; Ling LH; McLELLAN AJ; Lee G; Robinson T; Heck P; Halloran K; Morton J; Kistler P; Kalman JM; Sparks PB J Cardiovasc Electrophysiol; 2015 Feb; 26(2):119-26. PubMed ID: 25352207 [TBL] [Abstract][Full Text] [Related]
12. Ablation of atrial fibrillation and esophageal injury: Role of bipolar and unipolar energy using a novel multipolar irrigated ablation catheter. Di Monaco A; Quadrini F; Katsouras G; Caccavo V; Troisi F; Quatraro F; Cecere G; Langialonga T; Grimaldi M Heart Rhythm; 2015 Jun; 12(6):1120-7. PubMed ID: 25766775 [TBL] [Abstract][Full Text] [Related]
13. Luminal esophageal temperature rise and esophageal lesion formation following remote-controlled magnetic pulmonary vein isolation. Konstantinidou M; Wissner E; Chun JK; Koektuerk B; Metzner A; Tilz RR; Rillig A; Fuernkranz A; Wohlmuth P; Ouyang F; Kuck KH Heart Rhythm; 2011 Dec; 8(12):1875-80. PubMed ID: 21802392 [TBL] [Abstract][Full Text] [Related]
14. Computed tomographic analysis of the anatomy of the left atrium and the esophagus: implications for left atrial catheter ablation. Lemola K; Sneider M; Desjardins B; Case I; Han J; Good E; Tamirisa K; Tsemo A; Chugh A; Bogun F; Pelosi F; Kazerooni E; Morady F; Oral H Circulation; 2004 Dec; 110(24):3655-60. PubMed ID: 15569839 [TBL] [Abstract][Full Text] [Related]