179 related articles for article (PubMed ID: 20194936)
1. An integrated approach to computer-based automated tracing and its validation for 200 common carotid arterial wall ultrasound images: a new technique.
Molinari F; Zeng G; Suri JS
J Ultrasound Med; 2010 Mar; 29(3):399-418. PubMed ID: 20194936
[TBL] [Abstract][Full Text] [Related]
2. Carotid artery recognition system: a comparison of three automated paradigms for ultrasound images.
Molinari F; Meiburger KM; Zeng G; Acharya UR; Liboni W; Nicolaides A; Suri JS
Med Phys; 2012 Jan; 39(1):378-91. PubMed ID: 22225307
[TBL] [Abstract][Full Text] [Related]
3. Intima-media thickness: setting a standard for a completely automated method of ultrasound measurement.
Molinari F; Zeng G; Suri JS
IEEE Trans Ultrason Ferroelectr Freq Control; 2010 May; 57(5):1112-24. PubMed ID: 20442021
[TBL] [Abstract][Full Text] [Related]
4. Quantification of common carotid artery and descending aorta vessel wall thickness from MR vessel wall imaging using a fully automated processing pipeline.
Gao S; van 't Klooster R; Brandts A; Roes SD; Alizadeh Dehnavi R; de Roos A; Westenberg JJ; van der Geest RJ
J Magn Reson Imaging; 2017 Jan; 45(1):215-228. PubMed ID: 27251901
[TBL] [Abstract][Full Text] [Related]
5. Carotid automated ultrasound double line extraction system (CADLES) via Edge-Flow.
Meiburger KM; Molinari F; Zeng G; Saba L; Suri JS
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():575-8. PubMed ID: 22254375
[TBL] [Abstract][Full Text] [Related]
6. Fully automated dual-snake formulation for carotid intima-media thickness measurement. A new approach.
Molinari F; Meiburger KM; Saba L; Zeng G; Acharya UR; Ledda M; Nicolaides A; Suri JS
J Ultrasound Med; 2012 Jul; 31(7):1123-36. PubMed ID: 22733861
[TBL] [Abstract][Full Text] [Related]
7. Feature selection applied to ultrasound carotid images segmentation.
Rosati S; Molinari F; Balestra G
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():5161-4. PubMed ID: 22255501
[TBL] [Abstract][Full Text] [Related]
8. Three-dimensional ultrasound of carotid atherosclerosis: semiautomated segmentation using a level set-based method.
Ukwatta E; Awad J; Ward AD; Buchanan D; Samarabandu J; Parraga G; Fenster A
Med Phys; 2011 May; 38(5):2479-93. PubMed ID: 21776783
[TBL] [Abstract][Full Text] [Related]
9. Role of fuzzy pre-classifier for high performance LI/MA segmentation in B-mode longitudinal carotid ultrasound images.
Molinari F; Gaetano L; Balestra G; Suri JS
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():4719-22. PubMed ID: 21096016
[TBL] [Abstract][Full Text] [Related]
10. Automatic recognition of the common carotid artery in longitudinal ultrasound B-mode scans.
Rossi AC; Brands PJ; Hoeks AP
Med Image Anal; 2008 Dec; 12(6):653-65. PubMed ID: 18448382
[TBL] [Abstract][Full Text] [Related]
11. Real-time measurement system for the evaluation of the intima media thickness with a new edge detector.
Faita F; Gemignani V; Bianchini E; Giannarelli C; Demi M
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():715-8. PubMed ID: 17945599
[TBL] [Abstract][Full Text] [Related]
12. CARES 3.0: a two stage system combining feature-based recognition and edge-based segmentation for CIMT measurement on a multi-institutional ultrasound database of 300 images.
Molinari F; Meiburger KM; Acharya UR; Zeng G; Rodrigues PS; Saba L; Nicolaides A; Suri JS
Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():5149-52. PubMed ID: 22255498
[TBL] [Abstract][Full Text] [Related]
13. An integrated system for the segmentation of atherosclerotic carotid plaque.
Loizou CP; Pattichis CS; Pantziaris M; Nicolaides A
IEEE Trans Inf Technol Biomed; 2007 Nov; 11(6):661-7. PubMed ID: 18046941
[TBL] [Abstract][Full Text] [Related]
14. Segmentation of ultrasound images of the carotid using RANSAC and cubic splines.
Rocha R; Campilho A; Silva J; Azevedo E; Santos R
Comput Methods Programs Biomed; 2011 Jan; 101(1):94-106. PubMed ID: 20554343
[TBL] [Abstract][Full Text] [Related]
15. User-independent plaque characterization and accurate IMT measurement of carotid artery wall using ultrasound.
Delsanto S; Molinari F; Liboni W; Giustetto P; Badalamenti S; Suri JS
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2404-7. PubMed ID: 17946111
[TBL] [Abstract][Full Text] [Related]
16. An integrated system for the segmentation of atherosclerotic carotid plaque ultrasound video.
Loizou C; Petroudi S; Pantziaris M; Nicolaides A; Pattichis C
IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jan; 61(1):86-101. PubMed ID: 24402898
[TBL] [Abstract][Full Text] [Related]
17. Completely automated multiresolution edge snapper--a new technique for an accurate carotid ultrasound IMT measurement: clinical validation and benchmarking on a multi-institutional database.
Molinari F; Pattichis CS; Zeng G; Saba L; Acharya UR; Sanfilippo R; Nicolaides A; Suri JS
IEEE Trans Image Process; 2012 Mar; 21(3):1211-22. PubMed ID: 21947523
[TBL] [Abstract][Full Text] [Related]
18. Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach.
Krishna Kumar P; Araki T; Rajan J; Saba L; Lavra F; Ikeda N; Sharma AM; Shafique S; Nicolaides A; Laird JR; Gupta A; Suri JS
Med Biol Eng Comput; 2017 Aug; 55(8):1415-1434. PubMed ID: 27943087
[TBL] [Abstract][Full Text] [Related]
19. Automated analysis of intima-media thickness: analysis and performance of CARES 3.0.
Saba L; Montisci R; Famiglietti L; Tallapally N; Acharya UR; Molinari F; Sanfilippo R; Mallarini G; Nicolaides A; Suri JS
J Ultrasound Med; 2013 Jul; 32(7):1127-35. PubMed ID: 23804335
[TBL] [Abstract][Full Text] [Related]
20. Improved correlation between carotid and coronary atherosclerosis SYNTAX score using automated ultrasound carotid bulb plaque IMT measurement.
Ikeda N; Gupta A; Dey N; Bose S; Shafique S; Arak T; Godia EC; Saba L; Laird JR; Nicolaides A; Suri JS
Ultrasound Med Biol; 2015 May; 41(5):1247-62. PubMed ID: 25638311
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]