BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 20197646)

  • 1. Investigation of activation rate uniformity in a prompt-gamma rays IVNAA facility.
    Hakimabad HM; Motavalli LR
    J Radiat Res; 2010; 51(2):123-30. PubMed ID: 20197646
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo modelling of neutron depth dose distributions in optimizing prompt gamma in vivo neutron activation analysis systems.
    Utteridge TD; Ralston AC; Wallace SA; Allen BJ; Beddoe AH
    Appl Radiat Isot; 1994 Jul; 45(7):789-94. PubMed ID: 8061660
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New PTB thermal neutron calibration facility: first results.
    Luszik-Bhadra M; Reginatto M; Wershofen H; Wiegel B; Zimbal A
    Radiat Prot Dosimetry; 2014 Oct; 161(1-4):352-6. PubMed ID: 24403346
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improving the safety of a body composition analyser based on the PGNAA method.
    Miri-Hakimabad H; Izadi-Najafabadi R; Vejdani-Noghreiyan A; Panjeh H
    J Radiol Prot; 2007 Dec; 27(4):457-64. PubMed ID: 18268376
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo simulation of moderator and reflector in coal analyzer based on a D-T neutron generator.
    Shan Q; Chu S; Jia W
    Appl Radiat Isot; 2015 Nov; 105():204-208. PubMed ID: 26325583
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Facility optimization to improve activation rate distributions during IVNAA.
    Ebrahimi Khankook A; Rafat Motavalli L; Miri Hakimabad H
    J Radiat Res; 2013 May; 54(3):515-31. PubMed ID: 23386375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte Carlo simulation of prompt gamma neutron activation analysis using MCNP code.
    Evans CJ; Ryde SJ; Hancock DA; al-Agel F
    Appl Radiat Isot; 1998; 49(5-6):541-3. PubMed ID: 9569538
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo design study of a moderated 252Cf source for in vivo neutron activation analysis of aluminium.
    Lewis DG; Natto SS; Ryde SJ; Evans CJ
    Phys Med Biol; 1997 Apr; 42(4):625-36. PubMed ID: 9127441
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Benchmarking the MCNP code for Monte Carlo modelling of an in vivo neutron activation analysis system.
    Natto SA; Lewis DG; Ryde SJ
    Appl Radiat Isot; 1998; 49(5-6):545-7. PubMed ID: 9606084
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improvement of the prompt-gamma neutron activation facility at Brookhaven National Laboratory.
    Dilmanian FA; Lidofsky LJ; Stamatelatos I; Kamen Y; Yasumura S; Vartsky D; Pierson RN; Weber DA; Moore RI; Ma R
    Phys Med Biol; 1998 Feb; 43(2):339-49. PubMed ID: 9509530
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterisation of the IRSN graphite moderated Americium-Beryllium neutron field.
    Lacoste V; Gressier V; Muller H; Lebreton L;
    Radiat Prot Dosimetry; 2004; 110(1-4):135-9. PubMed ID: 15353636
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simulation of the cement measurement based on the pulse DT neutron generator: A Monte Carlo study.
    Gao Y; Li J; Li J; Liu L
    PLoS One; 2021; 16(6):e0252078. PubMed ID: 34125857
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam.
    Pejović-Milić A; Arnold ML; McNeill FE; Chettle DR
    Appl Radiat Isot; 2000; 53(4-5):657-64. PubMed ID: 11003504
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A compact neutron beam generator system designed for prompt gamma nuclear activation analysis.
    Ghassoun J; Mostacci D
    Appl Radiat Isot; 2011 Aug; 69(8):1138-42. PubMed ID: 21129990
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and verification of the shielding around the new Neutron Standards Laboratory (LPN) at CIEMAT.
    Méndez-Villafañe R; Guerrero JE; Embid M; Fernández R; Grandio R; Pérez-Cejuela P; Márquez JL; Alvarez F; Ortego P
    Radiat Prot Dosimetry; 2014 Oct; 161(1-4):393-7. PubMed ID: 24478306
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A fast response and gamma-insensitive neutron detector based on parallel-plate avalanche counter.
    Nakhostin M; Baba M; Itoga T; Oishi T; Unno Y; Kamada S; Okuji T
    Radiat Prot Dosimetry; 2008; 129(4):426-30. PubMed ID: 17998200
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermal neutron calibration channel at LNMRI/IRD.
    Astuto A; Salgado AP; Leite SP; Patrão KC; Fonseca ES; Pereira WW; Lopes RT
    Radiat Prot Dosimetry; 2014 Oct; 161(1-4):185-9. PubMed ID: 24625545
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Response components of LiF:Mg,Ti around a moderated Am-Be neutron source.
    Méndez R; Iñiguez MP; Barquero R; Mañanes A; Gallego E; Lorente A; Voytchev M
    Radiat Prot Dosimetry; 2002; 98(2):173-8. PubMed ID: 11926367
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A compact DD neutron generator-based NAA system to quantify manganese (Mn) in bone in vivo.
    Liu Y; Byrne P; Wang H; Koltick D; Zheng W; Nie LH
    Physiol Meas; 2014 Sep; 35(9):1899-911. PubMed ID: 25154883
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of the delayed-gamma neutron activation facility.
    Ma R; Zhao X; Rarback HM; Yasumura S; Dilmanian FA; Moore RI; Lo Monte AF; Vodopia KA; Liu HB; Economos CD; Nelson ME; Aloia JF; Vaswani AN; Weber DA; Pierson RN; Joel DD
    Med Phys; 1996 Feb; 23(2):273-7. PubMed ID: 8668109
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.