These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

282 related articles for article (PubMed ID: 20206693)

  • 1. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry.
    Vogeser M
    J Steroid Biochem Mol Biol; 2010 Aug; 121(3-5):565-73. PubMed ID: 20206693
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D
    Wise SA; Camara JE; Burdette CQ; Hahm G; Nalin F; Kuszak AJ; Merkel J; Durazo-Arvizu RA; Williams EL; Hoofnagle AN; Ivison F; Fischer R; van den Ouweland JMW; Ho CS; Law EWK; Simard JN; Gonthier R; Holmquist B; Meadows S; Cox L; Robyak K; Creer MH; Fitzgerald R; Clarke MW; Breen N; Lukas P; Cavalier É; Sempos CT
    Anal Bioanal Chem; 2022 Jan; 414(1):333-349. PubMed ID: 34432104
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Rapid and Simple Liquid-Chromatography-Tandem Mass Spectrometry Method for Measuring 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 in Human Serum: Comparison with Two Automated Immunoassays.
    Lee S; Kim JH; Kim SA; Sun YS; Lee A; Park SJ; Kim YT; Lee KR; Kim YJ
    Ann Clin Lab Sci; 2016 Dec; 46(6):645-653. PubMed ID: 27993879
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and application of a LC-MS/MS assay for simultaneous analysis of 25-hydroxyvitamin-D and 3-epi-25-hydroxyvitamin-D metabolites in canine serum.
    Hurst EA; Homer NZ; Denham SG; MacFarlane E; Campbell S; Boswinkel M; Mellanby RJ
    J Steroid Biochem Mol Biol; 2020 May; 199():105598. PubMed ID: 31958632
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurement of vitamin D.
    Ford L
    Methods Mol Biol; 2013; 1065():245-57. PubMed ID: 23996369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance evaluation of four 25-hydroxyvitamin D assays to measure 25-hydroxyvitamin D2.
    Freeman J; Wilson K; Spears R; Shalhoub V; Sibley P
    Clin Biochem; 2015 Nov; 48(16-17):1097-104. PubMed ID: 26054580
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE).
    Thibeault D; Caron N; Djiana R; Kremer R; Blank D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum.
    van den Ouweland JM; Beijers AM; van Daal H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():195-202. PubMed ID: 25125396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of 25-Hydroxyvitamin D2 and D3 Using Liquid Chromatography-Tandem Mass Spectrometry.
    Munar A; Clinton Frazee C; Garg U
    Methods Mol Biol; 2022; 2546():539-544. PubMed ID: 36127620
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and validation of an LC-MS/MS based method for quantification of 25 hydroxyvitamin D2 and 25 hydroxyvitamin D3 in human serum and plasma.
    Zhang SW; Jian W; Sullivan S; Sankaran B; Edom RW; Weng N; Sharkey D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Jun; 961():62-70. PubMed ID: 24861873
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay.
    van den Ouweland JM; Beijers AM; Demacker PN; van Daal H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 May; 878(15-16):1163-8. PubMed ID: 20381436
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy and clinical implications of seven 25-hydroxyvitamin D methods compared with liquid chromatography-tandem mass spectrometry as a reference.
    Roth HJ; Schmidt-Gayk H; Weber H; Niederau C
    Ann Clin Biochem; 2008 Mar; 45(Pt 2):153-9. PubMed ID: 18325178
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation.
    Bruce SJ; Rochat B; Béguin A; Pesse B; Guessous I; Boulat O; Henry H
    Rapid Commun Mass Spectrom; 2013 Jan; 27(1):200-6. PubMed ID: 23239334
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.
    Satoh M; Ishige T; Ogawa S; Nishimura M; Matsushita K; Higashi T; Nomura F
    Anal Bioanal Chem; 2016 Nov; 408(27):7617-7627. PubMed ID: 27526091
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous quantification of 25-hydroxyvitamin D
    Gao C; Bergagnini-Kolev MC; Liao MZ; Wang Z; Wong T; Calamia JC; Lin YS; Mao Q; Thummel KE
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Aug; 1060():158-165. PubMed ID: 28622619
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a LC-MS/MS method to measure serum 3-sulfate and 3-glucuronide 25-hydroxyvitamin D3 metabolites; comparisons to unconjugated 25OHD in pregnancy and polycystic ovary syndrome.
    Huynh K; Kempegowda P; Tamblyn J; O' Reilly MW; Mueller JW; Hewison M; Jenkinson C
    Steroids; 2021 May; 169():108812. PubMed ID: 33636208
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum.
    Jenkinson C; Taylor AE; Hassan-Smith ZK; Adams JS; Stewart PM; Hewison M; Keevil BG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Mar; 1014():56-63. PubMed ID: 26874878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhanced 3-epi-25-hydroxyvitamin D3 signal leads to overestimation of its concentration and amplifies interference in 25-hydroxyvitamin D LC-MS/MS assays.
    Flynn N; Lam F; Dawnay A
    Ann Clin Biochem; 2014 May; 51(Pt 3):352-9. PubMed ID: 24000372
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Phenotyping and relative quantification of vitamin D binding protein in a paediatric population by using liquid chromatography-tandem mass spectrometry.
    Cillero AI; Martínez-Morillo E; Mantecón L; Alonso MA; Gil-Peña H; Santos F; Álvarez FV
    Ann Clin Biochem; 2019 Jan; 56(1):56-63. PubMed ID: 29792047
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two-dimensional liquid chromatography coupled to tandem mass spectrometry for vitamin D metabolite profiling including the C3-epimer-25-monohydroxyvitamin D3.
    Mena-Bravo A; Priego-Capote F; Luque de Castro MD
    J Chromatogr A; 2016 Jun; 1451():50-57. PubMed ID: 27180887
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.