238 related articles for article (PubMed ID: 20214808)
1. Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests. Egerer K; Roggenbuck D; Hiemann R; Weyer MG; Büttner T; Radau B; Krause R; Lehmann B; Feist E; Burmester GR Arthritis Res Ther; 2010; 12(2):R40. PubMed ID: 20214808 [TBL] [Abstract][Full Text] [Related]
2. Challenges of automated screening and differentiation of non-organ specific autoantibodies on HEp-2 cells. Hiemann R; Büttner T; Krieger T; Roggenbuck D; Sack U; Conrad K Autoimmun Rev; 2009 Sep; 9(1):17-22. PubMed ID: 19245860 [TBL] [Abstract][Full Text] [Related]
3. Multiplex assessment of non-organ-specific autoantibodies with a novel microbead-based immunoassay. Grossmann K; Roggenbuck D; Schröder C; Conrad K; Schierack P; Sack U Cytometry A; 2011 Feb; 79(2):118-25. PubMed ID: 21265005 [TBL] [Abstract][Full Text] [Related]
4. A comparative study on the reliability of an automated system for the evaluation of cell-based indirect immunofluorescence. Melegari A; Bonaguri C; Russo A; Luisita B; Trenti T; Lippi G Autoimmun Rev; 2012 Aug; 11(10):713-6. PubMed ID: 22269861 [TBL] [Abstract][Full Text] [Related]
6. The detection of autoantibodies on HEp-2 cells using an indirect immunoperoxidase kit (Colorzyme). Fritzler MJ; Wall W; Gohill J; Kinsella TD; Humbel RL Diagn Immunol; 1986; 4(4):217-21. PubMed ID: 3530600 [TBL] [Abstract][Full Text] [Related]
7. Autoantibody detection using indirect immunofluorescence on HEp-2 cells. Sack U; Conrad K; Csernok E; Frank I; Hiepe F; Krieger T; Kromminga A; von Landenberg P; Messer G; Witte T; Mierau R; Ann N Y Acad Sci; 2009 Sep; 1173():166-73. PubMed ID: 19758146 [TBL] [Abstract][Full Text] [Related]
8. Indirect immunofluorescence in autoimmune diseases: assessment of digital images for diagnostic purpose. Rigon A; Soda P; Zennaro D; Iannello G; Afeltra A Cytometry B Clin Cytom; 2007 Nov; 72(6):472-7. PubMed ID: 17549740 [TBL] [Abstract][Full Text] [Related]
9. Novel opportunities in automated classification of antinuclear antibodies on HEp-2 cells. Rigon A; Buzzulini F; Soda P; Onofri L; Arcarese L; Iannello G; Afeltra A Autoimmun Rev; 2011 Aug; 10(10):647-52. PubMed ID: 21545848 [TBL] [Abstract][Full Text] [Related]
10. Detection of antinuclear antibodies: comparative evaluation of enzyme immunoassay and indirect immunofluorescence methods. Homburger HA; Cahen YD; Griffiths J; Jacob GL Arch Pathol Lab Med; 1998 Nov; 122(11):993-9. PubMed ID: 9822128 [TBL] [Abstract][Full Text] [Related]
11. Automatic analysis of immunofluorescence patterns of HEp-2 cells. Hiemann R; Hilger N; Michel J; Nitschke J; Böhm A; Anderer U; Weigert M; Sack U Ann N Y Acad Sci; 2007 Aug; 1109():358-71. PubMed ID: 17785325 [TBL] [Abstract][Full Text] [Related]
13. New platform technology for comprehensive serological diagnostics of autoimmune diseases. Willitzki A; Hiemann R; Peters V; Sack U; Schierack P; Rödiger S; Anderer U; Conrad K; Bogdanos DP; Reinhold D; Roggenbuck D Clin Dev Immunol; 2012; 2012():284740. PubMed ID: 23316252 [TBL] [Abstract][Full Text] [Related]
14. Automated indirect immunofluorescence antinuclear antibody analysis is a standardized alternative for visual microscope interpretation. Bonroy C; Verfaillie C; Smith V; Persijn L; De Witte E; De Keyser F; Devreese K Clin Chem Lab Med; 2013 Sep; 51(9):1771-9. PubMed ID: 23612554 [TBL] [Abstract][Full Text] [Related]
15. Clinical value of anti-DFS70 antibodies in a cohort of patients undergoing routine antinuclear antibodies testing. Yumuk Z; Demir M J Immunol Methods; 2020 May; 480():112754. PubMed ID: 32057435 [TBL] [Abstract][Full Text] [Related]
16. EUROPattern Suite technology for computer-aided immunofluorescence microscopy in autoantibody diagnostics. Krause C; Ens K; Fechner K; Voigt J; Fraune J; Rohwäder E; Hahn M; Danckwardt M; Feirer C; Barth E; Martinetz T; Stöcker W Lupus; 2015 Apr; 24(4-5):516-29. PubMed ID: 25801895 [TBL] [Abstract][Full Text] [Related]
17. Measurement of autoantibodies using multiplex methodology in patients with systemic lupus erythematosus. Hanly JG; Thompson K; McCurdy G; Fougere L; Theriault C; Wilton K J Immunol Methods; 2010 Jan; 352(1-2):147-52. PubMed ID: 19836394 [TBL] [Abstract][Full Text] [Related]
18. Can an ELISA replace immunofluorescence for the detection of anti-nuclear antibodies?--The routine use of anti-nuclear antibody screening ELISAs. Sinclair D; Saas M; Williams D; Hart M; Goswami R Clin Lab; 2007; 53(3-4):183-91. PubMed ID: 17447656 [TBL] [Abstract][Full Text] [Related]
19. A fully automated IIF system for the detection of antinuclear antibodies and antineutrophil cytoplasmic antibodies. Shovman O; Agmon-Levin N; Gilburd B; Martins T; Petzold A; Matthias T; Shoenfeld Y Immunol Res; 2015 Feb; 61(1-2):135-40. PubMed ID: 25403695 [TBL] [Abstract][Full Text] [Related]
20. Comparison of a multiplex, bead-based fluorescent assay and immunofluorescence methods for the detection of ANA and ANCA autoantibodies in human serum. Nifli AP; Notas G; Mamoulaki M; Niniraki M; Ampartzaki V; Theodoropoulos PA; Kopnitsky MJ; Castanas E J Immunol Methods; 2006 Apr; 311(1-2):189-97. PubMed ID: 16554066 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]