These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 20216620)

  • 1. Remote measurement of gaseous pollutant concentrations using a mobile Fourier transform interferometer system.
    Herget WF; Brasher JD
    Appl Opt; 1979 Oct; 18(20):3404-20. PubMed ID: 20216620
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Remote and cross-stack measurement of stack gas concentrations using a mobile FT-IR system.
    Herget WF
    Appl Opt; 1982 Feb; 21(4):635-41. PubMed ID: 20372510
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Studies on the determination of the flux of gaseous pollutant from an area by passive differential optical absorption spectroscopy].
    Li A; Xie PH; Liu WQ; Liu JG; Dou K
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Jan; 29(1):28-32. PubMed ID: 19385199
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative determination of ethanol in heated plumes by passive Fourier transform infrared remote sensing measurements.
    Sulub Y; Small GW
    Analyst; 2007 Apr; 132(4):330-7. PubMed ID: 17554412
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Near UV-near IR Fourier transform spectrometer using the beam-folding position-tracking method based on retroreflectors.
    Wang X; Chan RK; Cheng AS
    Rev Sci Instrum; 2008 Dec; 79(12):123108. PubMed ID: 19123546
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Air pollution measurement by Fourier transform spectroscopy.
    Hanst PL
    Appl Opt; 1978 May; 17(9):1360-6. PubMed ID: 20197989
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multichannel Fourier-transform infrared spectrometer.
    Hashimoto M; Kawata S
    Appl Opt; 1992 Oct; 31(28):6096-101. PubMed ID: 20733812
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calibrated 0.1-cm(-1) IR emission spectra from 80°N.
    Olson JR; Van Allen J; Fogal PF; Murcray FJ; Goldman A
    Appl Opt; 1996 Jun; 35(16):2797-801. PubMed ID: 21085427
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Developing and evaluating techniques for localizing pollutant emission sources with open-path Fourier transform infrared measurements and wind data.
    Wu CF; Chen CH; Chang SY; Chang PE; Shie RH; Sung LY; Yang JC; Su JW
    J Air Waste Manag Assoc; 2008 Oct; 58(10):1360-9. PubMed ID: 18939783
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hyperspectral quantitative imaging of gas sources in the mid-infrared.
    Rodríguez-Conejo MA; Meléndez J
    Appl Opt; 2015 Jan; 54(2):141-9. PubMed ID: 25967610
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Optical-fiber Fourier transform spectrometer].
    Liu Y; Li BS; Liu Y; Zhai YF; Wang A
    Guang Pu Xue Yu Guang Pu Fen Xi; 2006 Oct; 26(10):1951-4. PubMed ID: 17205761
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Infrared gas-filter correlation instrument for in situ measurement of gaseous pollutant concentrations.
    Herget WF; Jahnke JA; Burch DE; Gryvnak DA
    Appl Opt; 1976 May; 15(5):1222-8. PubMed ID: 20165155
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Studies on the remote measurement of the distribution of city gaseous pollutant by mobile passive differential optical absorption spectroscopy].
    Wu FC; Li A; Xie PH; Xu J; Shi P; Qin M; Wang MH; Wang J; Zhang Y
    Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Mar; 31(3):583-8. PubMed ID: 21595196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Fourier Transform Spectrometer for the 10-10,000 cm(-1) Spectral Region.
    Hochheimer BF; Bradley CF
    Appl Opt; 1969 Mar; 8(3):557-62. PubMed ID: 20072257
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Combustion temperature measurement of pyrotechnic composition using remote sensing Fourier transform infrared spectrometry].
    Zhou XL; Li Y; Liu ZL; Zhu CJ; Wang JD; Lu CX
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Oct; 22(5):764-6. PubMed ID: 12938424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Remote identification and quantification of industrial smokestack effluents via imaging Fourier-transform spectroscopy.
    Gross KC; Bradley KC; Perram GP
    Environ Sci Technol; 2010 Dec; 44(24):9390-7. PubMed ID: 21069951
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polarization modulation high resolution Fourier transform spectroscopy.
    Elhanine M; Farrenq R; Guelachvili G
    Appl Opt; 1989 Sep; 28(18):4024-9. PubMed ID: 20555815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Method of spectral subtraction of gas-phase Fourier transform infrared (FT-IR) spectra by minimizing the spectrum length.
    Kozlov D; Besov A
    Appl Spectrosc; 2011 Aug; 65(8):918-23. PubMed ID: 21819781
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fourier transform infrared measurement of solid-, liquid-, and gas-phase samples with a single photoacoustic cell.
    Uotila J; Kauppinen J
    Appl Spectrosc; 2008 Jun; 62(6):655-60. PubMed ID: 18559153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fourier-transform absorption spectroscopy in reciprocating engines.
    Rein KD; Sanders ST
    Appl Opt; 2010 Sep; 49(25):4728-34. PubMed ID: 20820214
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.