BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 20218902)

  • 1. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes?
    Dimeski G; Masci PP; Trabi M; Lavin MF; de Jersey J
    Clin Chem Lab Med; 2010 May; 48(5):651-7. PubMed ID: 20218902
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the Greiner Bio-One serum separator BCA Fast Clot tube.
    Dimeski G; Johnston J; Masci PP; Zhao KN; Brown N
    Clin Chem Lab Med; 2017 Jul; 55(8):1135-1141. PubMed ID: 28076307
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.
    Kocijancic M; Cargonja J; Delic-Knezevic A
    Biochem Med (Zagreb); 2014; 24(3):368-75. PubMed ID: 25351355
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.
    Arslan FD; Karakoyun I; Basok BI; Aksit MZ; Baysoy A; Ozturk YK; Guclu YA; Duman C
    Biochem Med (Zagreb); 2017 Oct; 27(3):030706. PubMed ID: 28900369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of BD Vacutainer® Rapid Serum Tube and plasma for haemolysis markers in the emergency department.
    Ryan JB; Stuart LA; Southby SJ; Than MP; Mackay R; Florkowski CM; George PM
    Ann Clin Biochem; 2015 Mar; 52(Pt 2):293-6. PubMed ID: 24714681
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of Barricor™
    Dupuy AM; Badiou S; Daubin D; Bargnoux AS; Magnan C; Klouche K; Cristol JP
    Biochem Med (Zagreb); 2018 Jun; 28(2):020902. PubMed ID: 29666561
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes.
    Chance J; Berube J; Vandersmissen M; Blanckaert N
    Clin Chem Lab Med; 2009; 47(3):358-61. PubMed ID: 19676149
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Becton Dickinson Vacutainer rapid serum tube with the serum separator tube for routine chemistry and immunoassay tests.
    Yan R; Lou A; Watts G; Tarr H; Smith H; Kinney L; Chen Y
    J Clin Pathol; 2014 Jul; 67(7):599-604. PubMed ID: 24687321
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use.
    O'Keane MP; Cunningham SK
    Clin Chem Lab Med; 2006; 44(5):662-8. PubMed ID: 16681442
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests.
    Kösem A; Topçuoğlu C; Sezer S; Cevher ŞK; Yenigün EC; Dede F; Turhan T
    Clin Lab; 2019 Dec; 65(12):. PubMed ID: 31850716
    [TBL] [Abstract][Full Text] [Related]  

  • 11. BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer.
    Koch CD; Wockenfus AM; Saenger AK; Jaffe AS; Karon BS
    Clin Biochem; 2012 Jul; 45(10-11):842-4. PubMed ID: 22561083
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Recentrifugation of Lithium Heparin Gel Separator Tubes up to 8 h after Blood Collection Has No Relevant Influence on the Stability of 30 Routine Biochemical Analytes.
    van Balveren JA; Gemen EFA; Kusters R
    J Appl Lab Med; 2019 Mar; 3(5):864-869. PubMed ID: 31639761
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and gamma-glutamyltransferase.
    Lippi G; Avanzini P; Cosmai M; Aloe R; Ernst D
    Br J Biomed Sci; 2012; 69(2):67-70. PubMed ID: 22872930
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Test results comparison and sample stability study: is the BD Barricor tube a suitable replacement for the BD RST tube?
    Mandić S; Mandić D; Lukić I; Rolić T; Horvat V; Lukić M; Osvald S; Šerić V
    Biochem Med (Zagreb); 2020 Oct; 30(3):030704. PubMed ID: 33071555
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.
    Shin S; Oh J; Park HD
    Ann Lab Med; 2021 Jan; 41(1):114-119. PubMed ID: 32829587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biochemical, immunochemical and serology analytes validation of the lithium heparin BD Barricor blood collection tube on a highly automated Roche COBAS8000 instrument.
    Ferrari D; Strollo M; Vidali M; Motta A; Pontillo M; Locatelli M
    Acta Biomed; 2020 Mar; 91(1):47-55. PubMed ID: 32191654
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect on 16 analytes of overnight storage of specimens collected into heparinised evacuated tubes with plasma separator.
    Bailey IR
    Ann Clin Biochem; 1990 Jan; 27 ( Pt 1)():56-8. PubMed ID: 2135631
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.
    Strathmann FG; Ka MM; Rainey PM; Baird GS
    Am J Clin Pathol; 2011 Aug; 136(2):325-9. PubMed ID: 21757607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is it possible to use expired tubes for routine biochemical analysis in dogs?
    Domingos MC; Médaille C; Concordet D; Briend-Marchal A
    Vet Clin Pathol; 2012 Jun; 41(2):266-71. PubMed ID: 22551094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of stability of chemical analytes in plasma from the BD Vacutainer
    Gawria G; Tillmar L; Landberg E
    J Clin Lab Anal; 2020 Feb; 34(2):e23060. PubMed ID: 31605419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.