These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
175 related articles for article (PubMed ID: 20221089)
1. Design of a multiple-zone aperture and application to a Fabry-Perot interferometer. Okano S; Kim JS; Ichikawa T Appl Opt; 1980 May; 19(10):1622-9. PubMed ID: 20221089 [TBL] [Abstract][Full Text] [Related]
2. A technique for recovering Doppler line profiles from fabry-perot interferometer fringes of very low intensity. Hays PB; Roble RG Appl Opt; 1971 Jan; 10(1):193-200. PubMed ID: 20094416 [TBL] [Abstract][Full Text] [Related]
3. Fabry-Pérot interferometer utilized for displacement measurement in a large measuring range. Wang YC; Shyu LH; Chang CP Rev Sci Instrum; 2010 Sep; 81(9):093102. PubMed ID: 20886971 [TBL] [Abstract][Full Text] [Related]
4. Influence of intensity loss in the cavity of a folded Fabry-Perot interferometer on interferometric signals. Shyu LH; Chang CP; Wang YC Rev Sci Instrum; 2011 Jun; 82(6):063103. PubMed ID: 21721670 [TBL] [Abstract][Full Text] [Related]
5. A two-channel Fabry-Perot interferometer for the measurement of Doppler temperatures. Platz P Appl Opt; 1967 Jul; 6(7):1205-7. PubMed ID: 20062164 [TBL] [Abstract][Full Text] [Related]
6. Fabry-Perot interferometers with electronic determination of Doppler line widths. Best GT Appl Opt; 1967 Feb; 6(2):287-95. PubMed ID: 20057743 [TBL] [Abstract][Full Text] [Related]
7. Nonlinear regression method for estimating neutral wind and temperature from Fabry-Perot interferometer data. Harding BJ; Gehrels TW; Makela JJ Appl Opt; 2014 Feb; 53(4):666-73. PubMed ID: 24514183 [TBL] [Abstract][Full Text] [Related]
8. Application of a Fabry-Perot spectrometer to the measurement of spectral line shifts much smaller than line width. Döbele HF; Massig JH Appl Opt; 1976 Jan; 15(1):69-72. PubMed ID: 20155185 [TBL] [Abstract][Full Text] [Related]
9. Analytical description of a Fabry-Perot spectrometer. 5: Optimization for minimum uncertainties in the determination of Doppler widths and shifts. Hernandez G Appl Opt; 1979 Nov; 18(22):3826-34. PubMed ID: 20216700 [TBL] [Abstract][Full Text] [Related]
10. Experimental study of the effect of surface defects on the finesse and contrast of a Fabry-Perot interferometer. Palik ED; Boukari H; Gammon RW Appl Opt; 1996 Jan; 35(1):38-50. PubMed ID: 21068975 [TBL] [Abstract][Full Text] [Related]
11. Galatry profile convolved with the Fabry-Perot instrument function. Goorvitch D Appl Opt; 1977 Jun; 16(6):1732-5. PubMed ID: 20168780 [TBL] [Abstract][Full Text] [Related]
12. Atmospheric temperature sensing with a multiorder Fabry-Perot interferometer. Wang J; Drayson SR; Hayes PB Appl Opt; 1989 Dec; 28(23):5038-46. PubMed ID: 20555996 [TBL] [Abstract][Full Text] [Related]
13. A moiré fringe method of Fabry-Perot spectrometer scanning. Shepherd GG; Paffrath L Appl Opt; 1967 Oct; 6(10):1659-63. PubMed ID: 20062284 [TBL] [Abstract][Full Text] [Related]
14. Seven-channel fabry-perot spectrum analyzer used in laser scattering measurements. John PK; Benesch R Appl Opt; 1972 Jan; 11(1):153-9. PubMed ID: 20111471 [TBL] [Abstract][Full Text] [Related]