These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 20224249)

  • 1. Evaluation of a system for transcutaneous long-term capnometry.
    Randerath WJ; Stieglitz S; Galetke W; Anduleit N; Treml M; Schäfer T
    Respiration; 2010; 80(2):139-45. PubMed ID: 20224249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a combined transcutaneous carbon dioxide pressure and pulse oximetry sensor in adult sheep and dogs.
    Vogt R; Rohling R; Kästner S
    Am J Vet Res; 2007 Mar; 68(3):265-70. PubMed ID: 17331015
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An evaluation of a new combined Spo2/PtcCO2 sensor in very low birth weight infants.
    Lacerenza S; De Carolis MP; Fusco FP; La Torre G; Chiaradia G; Romagnoli C
    Anesth Analg; 2008 Jul; 107(1):125-9. PubMed ID: 18635477
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Repeated blood gas monitoring in healthy children and adolescents by the transcutaneous route.
    Lagerkvist AL; Sten G; Redfors S; Holmgren D
    Pediatr Pulmonol; 2003 Apr; 35(4):274-9. PubMed ID: 12629624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department.
    McVicar J; Eager R
    Emerg Med J; 2009 May; 26(5):344-6. PubMed ID: 19386868
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
    Lehmann KA; Asoklis S; Grond S; Huttarsch H
    Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcutaneous carbon dioxide monitoring in spontaneously breathing, nonintubated patients in the early postoperative period.
    Fanelli G; Baciarello M; Squicciarini G; Malagutti G; Zasa M; Casati A
    Minerva Anestesiol; 2008; 74(7-8):375-80. PubMed ID: 18612267
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems.
    Bolliger D; Steiner LA; Kasper J; Aziz OA; Filipovic M; Seeberger MD
    Anaesthesia; 2007 Apr; 62(4):394-9. PubMed ID: 17381578
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is transcutaneous oxygen and carbon dioxide monitoring indispensable in short- and long-term therapeutic management of non-reconstructable lower critical limb ischemia?
    Melillo E; Nuti M; Pedrinelli R; Buttitta F; Balbarini A
    Minerva Cardioangiol; 2006 Aug; 54(4):481-98. PubMed ID: 17016419
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
    Carter R; Banham SW
    Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Longtime performance and reliability of two different PtcCO2 and SpO2 sensors in neonates.
    Bernet V; Döll C; Cannizzaro V; Ersch J; Frey B; Weiss M
    Paediatr Anaesth; 2008 Sep; 18(9):872-7. PubMed ID: 18768047
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcutaneous carbon dioxide monitoring accurately predicts arterial carbon dioxide partial pressure in patients undergoing prolonged laparoscopic surgery.
    Xue Q; Wu X; Jin J; Yu B; Zheng M
    Anesth Analg; 2010 Aug; 111(2):417-20. PubMed ID: 20584872
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of ear and chest probes in transcutaneous carbon dioxide pressure measurements during general anesthesia in adults.
    Nishiyama T; Kohno Y; Koishi K
    J Clin Monit Comput; 2011 Oct; 25(5):323-8. PubMed ID: 22009107
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Continuous free-flap monitoring with tissue-oxygen measurements: experiences of the last years].
    Kamolz LP; Schrögendorfer KF; Giovanoli P; Koller R; Frey M
    Handchir Mikrochir Plast Chir; 2002 May; 34(3):195-200. PubMed ID: 12203156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Circulatory response to blood gas perturbations in vasospasm.
    Gugleta K; Orgül S; Hasler P; Flammer J
    Invest Ophthalmol Vis Sci; 2005 Sep; 46(9):3288-94. PubMed ID: 16123431
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation.
    Aliwalas LL; Noble L; Nesbitt K; Fallah S; Shah V; Shah PS
    J Perinatol; 2005 Jan; 25(1):26-9. PubMed ID: 15496874
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of reference ranges for transcutaneous oxygen and carbon dioxide tension and the oxygen challenge test in healthy and morbidly obese subjects.
    Nishiguchi BK; Yu M; Suetsugu A; Jiang C; Takiguchi SA; Takanishi DM
    J Surg Res; 2008 Dec; 150(2):204-11. PubMed ID: 18262560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An ambulatory system for long-term continuous monitoring of transcutaneous PCO2.
    Pilsbury D; Hibbert G
    Bull Eur Physiopathol Respir; 1987; 23(1):9-13. PubMed ID: 3109532
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.