These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 20224879)

  • 1. A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry.
    Wang L; Wei W; Gong M; Mu L
    J Clin Monit Comput; 2010 Apr; 24(2):149-53. PubMed ID: 20224879
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The pulmonary arterial oxygen saturation monitoring via trachea in hypoxia dogs].
    Gong Q; Wang L; Wei W; Yang Z; Mou L; Liu Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):752-6. PubMed ID: 19813603
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A pilot study of continuous transtracheal mixed venous oxygen saturation monitoring.
    Wei W; Zhu Z; Liu L; Zuo Y; Gong M; Xue F; Liu J
    Anesth Analg; 2005 Aug; 101(2):440-443. PubMed ID: 16037159
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Significant Delay in the Detection of Desaturation between Finger Transmittance and Earlobe Reflectance Oximetry Probes during Fiberoptic Bronchoscopy: Analysis of 104 Cases.
    Pertzov B; Brachfeld E; Unterman A; Gershman E; Abdel-Rahman N; Rosengarten D; Kramer MR
    Lung; 2019 Feb; 197(1):67-72. PubMed ID: 30474708
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Transesophageal arterial oxygen saturation monitoring: an experimental study].
    Zhu ZQ; Wei W; Yang ZB; Liu AJ; Liu J
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2005 Jan; 36(1):124-6. PubMed ID: 15702800
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of continuous central venous oxygen saturation monitoring in patients undergoing cardiac surgery.
    Baulig W; Dullenkopf A; Kobler A; Baulig B; Roth HR; Schmid ER
    J Clin Monit Comput; 2008 Jun; 22(3):183-8. PubMed ID: 18443743
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters.
    Choi SJ; Ahn HJ; Yang MK; Kim CS; Sim WS; Kim JA; Kang JG; Kim JK; Kang JY
    Acta Anaesthesiol Scand; 2010 Feb; 54(2):212-7. PubMed ID: 19719816
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy and reliability of pulse oximetry at different arterial carbon dioxide pressure levels.
    Muñoz X; Torres F; Sampol G; Rios J; Martí S; Escrich E
    Eur Respir J; 2008 Oct; 32(4):1053-9. PubMed ID: 18480106
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A pilot study of left tracheal pulse oximetry.
    Brimacombe J; Keller C; Margreiter J
    Anesth Analg; 2000 Oct; 91(4):1003-6. PubMed ID: 11004064
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion.
    Schallom L; Sona C; McSweeney M; Mazuski J
    Heart Lung; 2007; 36(3):188-94. PubMed ID: 17509425
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
    Pal SK; Kyriacou PA; Kumaran S; Fadheel S; Emamdee R; Langford RM; Jones DP
    Burns; 2005 May; 31(3):337-41. PubMed ID: 15774290
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of sensor site location on pulse oximetry kinetics in children.
    Reynolds LM; Nicolson SC; Steven JM; Escobar A; McGonigle ME; Jobes DR
    Anesth Analg; 1993 Apr; 76(4):751-4. PubMed ID: 8466011
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia.
    Chen G; Zhu Z; Liu J; Wei W
    Front Med; 2012 Dec; 6(4):406-10. PubMed ID: 23054501
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of three oxygen monitors in detecting endobronchial intubation.
    Barker SJ; Tremper KK; Hyatt J; Heitzmann H
    J Clin Monit; 1988 Oct; 4(4):240-3. PubMed ID: 3193146
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
    Giguère S; Sanchez LC; Shih A
    J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improving diagnostic ability of blood oxygen saturation from overnight pulse oximetry in obstructive sleep apnea detection by means of central tendency measure.
    Alvarez D; Hornero R; García M; del Campo F; Zamarrón C
    Artif Intell Med; 2007 Sep; 41(1):13-24. PubMed ID: 17643971
    [TBL] [Abstract][Full Text] [Related]  

  • 17. How accurate are pulse oximeters in patients with acute exacerbations of chronic obstructive airways disease?
    Kelly AM; McAlpine R; Kyle E
    Respir Med; 2001 May; 95(5):336-40. PubMed ID: 11392573
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of transmittance and reflectance pulse oximetry during vascular surgery.
    Wax DB; Rubin P; Neustein S
    Anesth Analg; 2009 Dec; 109(6):1847-9. PubMed ID: 19923513
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulse oximetry using a disposable finger sensor placed on the forehead in hypoxic patients.
    Smithline HA; Rudnitzky N; Macomber S; Blank FS
    J Emerg Med; 2010 Jul; 39(1):121-5. PubMed ID: 19406607
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of pulse oximetry and capnography in healthy and compromised horses during spontaneous and controlled ventilation.
    Koenig J; McDonell W; Valverde A
    Can J Vet Res; 2003 Jul; 67(3):169-74. PubMed ID: 12889721
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.