These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

270 related articles for article (PubMed ID: 20224933)

  • 1. [Stored electrograms in pacemakers and ICDs from Medtronic].
    Kloppe A; Kloppe C; Lemke B; Zarse M
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):26-40. PubMed ID: 20224933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Stored electrograms in pacemakers and ICDs from Boston Scientific].
    Schaumann A; Israel CW
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):18-25. PubMed ID: 20229193
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Analysis of intracardial electrograms in pacemakers and ICD systems by Biotronik].
    Wetzel U; Piorkowski C; Richter S; Müssigbrodt A; Kucher A; Hindricks G
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):6-17. PubMed ID: 20309671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Stored electrograms in pacemakers and ICDs from St. Jude Medical].
    Israel CW
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):53-70. PubMed ID: 20309672
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Stored electrograms in pacemakers and ICD systems from the Sorin Group].
    Mletzko RU; Ocklenburg R; Prizelius L
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):41-52. PubMed ID: 20198377
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Stored electrograms in pacemakers and ICDs].
    Israel CW
    Herzschrittmacherther Elektrophysiol; 2010 Mar; 21(1):3-5. PubMed ID: 20229194
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pacemakers and implantable cardiac defibrillators in dermatologic surgery.
    Matzke TJ; Christenson LJ; Christenson SD; Atanashova N; Otley CC
    Dermatol Surg; 2006 Sep; 32(9):1155-62; discussion 1162. PubMed ID: 16970697
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Device sensing: sensors and algorithms for pacemakers and implantable cardioverter defibrillators.
    Kaszala K; Ellenbogen KA
    Circulation; 2010 Sep; 122(13):1328-40. PubMed ID: 20876446
    [No Abstract]   [Full Text] [Related]  

  • 9. Pacemaker stored electrograms: teaching us what is really going on in our patients.
    Nowak B
    Pacing Clin Electrophysiol; 2002 May; 25(5):838-49. PubMed ID: 12049378
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A fiberoptic sensor system for cardiac monitoring and electrotherapy.
    Müller S; Kloppe A; Mügge A; Werner J
    Biomed Tech (Berl); 2004 Nov; 49(11):311-5. PubMed ID: 15624868
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Permanent pacemakers and implantable defibrillators: considerations for intensivists.
    McPherson CA; Manthous C
    Am J Respir Crit Care Med; 2004 Nov; 170(9):933-40. PubMed ID: 15297272
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Pacemakers and defibrillators: what should we know about home monitoring?].
    Amara W; Sergent J
    Ann Cardiol Angeiol (Paris); 2006 Nov; 55(6):315-20. PubMed ID: 17191589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved pacemaker pulse detection: clinical evaluation of a new high-bandwidth electrocardiographic system.
    Ricke AD; Swiryn S; Bauernfeind RA; Conner JA; Young B; Rowlandson GI
    J Electrocardiol; 2011; 44(2):265-74. PubMed ID: 21146832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Troubleshooting pacemakers and implantable cardioverter-defibrillators.
    Scher DL
    Curr Opin Cardiol; 2004 Jan; 19(1):36-46. PubMed ID: 14688633
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implanted pacemakers, cardioverters, defibrillators in dental patients device review and case presentation: something "shocking" might be good for your patient!
    Cohen HV; Hartwell G; Cicalese C
    J N J Dent Assoc; 2008; 79(3):38-40. PubMed ID: 18856181
    [No Abstract]   [Full Text] [Related]  

  • 16. Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database.
    Lazarus A
    Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S2-S12. PubMed ID: 17302706
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A fiber optic sensor system for control of rate-adaptive cardiac pacemakers and implantable defibrillators.
    Müller S; Hexamer M; Werner J
    Biomed Tech (Berl); 2006 Dec; 51(5-6):331-6. PubMed ID: 17155869
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pacemaker/defibrillator evaluation at Los Angeles County Department of Coroner*.
    Saint-Martin P; Rogers C; Muto J; Boyle NG; Rieders D; Sathyavagiswaran L
    J Forensic Sci; 2008 Sep; 53(5):1160-5. PubMed ID: 18637876
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The place of telemedicine in rhythmology and cardiac pacing].
    Lamaison D; Motreff P; Jean F; Geoffroy E; Rodriguez R; Souteyrand G; Chanseaume S; Terrazoni S; Cassagnes J
    Arch Mal Coeur Vaiss; 2004 Nov; 97(11):1160-4. PubMed ID: 15609921
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The reliability of computer-assisted long-term ECG analysis of pacemaker malfunction in patients with ventricular demand pacemakers].
    Brandes A; Gonska BD; Distler WK; Diederich KW; Bethge KP
    Z Kardiol; 1994 May; 83(5):351-8. PubMed ID: 8053244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.