These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 20305135)

  • 1. Microemboli, developed during haemodialysis, pass the lung barrier and may cause ischaemic lesions in organs such as the brain.
    Forsberg U; Jonsson P; Stegmayr C; Stegmayr B
    Nephrol Dial Transplant; 2010 Aug; 25(8):2691-5. PubMed ID: 20305135
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Patent foramen ovale, dialysis and microembolization.
    George S; Holt S; Hildick-Smith D
    Nephrology (Carlton); 2012 Aug; 17(6):569-74. PubMed ID: 22487266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microbubbles of air may occur in the organs of hemodialysis patients.
    Stegmayr B; Brännström T; Forsberg U; Jonson P; Stegmayr C; Hultdin J
    ASAIO J; 2012; 58(2):177-9. PubMed ID: 22236622
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sources of Mortality on Dialysis with an Emphasis on Microemboli.
    Stegmayr BG
    Semin Dial; 2016 Nov; 29(6):442-446. PubMed ID: 27528100
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A high blood level in the air trap reduces microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Stegmayr B
    Artif Organs; 2012 Jun; 36(6):525-9. PubMed ID: 22360799
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Air bubbles pass the security system of the dialysis device without alarming.
    Jonsson P; Karlsson L; Forsberg U; Gref M; Stegmayr C; Stegmayr B
    Artif Organs; 2007 Feb; 31(2):132-9. PubMed ID: 17298402
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Jonsson F; Nilsson B; Nilsson Ekdahl K; Stegmayr B
    Hemodial Int; 2013 Oct; 17(4):612-7. PubMed ID: 23627921
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Left ventricular growth after 1 year of haemodialysis does not correlate with arteriovenous access flow: a prospective cohort study.
    Hiremath S; Doucette SP; Richardson R; Chan K; Burns K; Zimmerman D
    Nephrol Dial Transplant; 2010 Aug; 25(8):2656-61. PubMed ID: 20185857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is intra-operative blood flow predictive for early failure of radiocephalic arteriovenous fistula?
    Saucy F; Haesler E; Haller C; Déglise S; Teta D; Corpataux JM
    Nephrol Dial Transplant; 2010 Mar; 25(3):862-7. PubMed ID: 19892754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Factors influencing the prevalence of central venous catheter use in a Canadian haemodialysis centre.
    Graham J; Hiremath S; Magner PO; Knoll GA; Burns KD
    Nephrol Dial Transplant; 2008 Nov; 23(11):3585-91. PubMed ID: 18552397
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of microemboli in the subclavian vein of patients undergoing haemodialysis and haemodiafiltration using pulsed Doppler ultrasound.
    Droste DW; Kühne K; Schaefer RM; Ringelstein EB
    Nephrol Dial Transplant; 2002 Mar; 17(3):462-6. PubMed ID: 11865093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cerebral microemboli and brain injury during carotid artery endarterectomy and stenting.
    Skjelland M; Krohg-Sørensen K; Tennøe B; Bakke SJ; Brucher R; Russell D
    Stroke; 2009 Jan; 40(1):230-4. PubMed ID: 18927460
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Identification of microemboli during haemodialysis using Doppler ultrasound.
    Rollé F; Pengloan J; Abazza M; Halimi JM; Laskar M; Pourcelot L; Tranquart F
    Nephrol Dial Transplant; 2000 Sep; 15(9):1420-4. PubMed ID: 10978401
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis.
    Stegmayr B; Forsberg U; Jonsson P; Stegmayr C
    Artif Organs; 2007 Feb; 31(2):162-6. PubMed ID: 17298408
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Air contamination during hemodialysis should be minimized.
    Stegmayr B
    Hemodial Int; 2017 Apr; 21(2):168-172. PubMed ID: 27576675
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Acoustical bubble trapper applied to hemodialysis.
    Palanchon P; Birmelé B; Tranquart F
    Ultrasound Med Biol; 2008 Apr; 34(4):681-4. PubMed ID: 17996355
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pathophysiology and clinical implications of microbubbles during hemodialysis.
    Barak M; Nakhoul F; Katz Y
    Semin Dial; 2008; 21(3):232-8. PubMed ID: 18363602
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Air contamination during medical treatment results in deposits of microemboli in the lungs: An autopsy study.
    Forsberg U; Jonsson P; Stegmayr B
    Int J Artif Organs; 2019 Sep; 42(9):477-481. PubMed ID: 30973284
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness of microbubble removal in an airtrap with a free surface interface.
    Keshavarzi G; Simmons A; Yeoh G; Barber T
    J Biomech; 2015 May; 48(7):1237-40. PubMed ID: 25841295
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap.
    Stegmayr C; Jonsson P; Forsberg U; Stegmayr B
    Int J Artif Organs; 2008 Apr; 31(4):317-22. PubMed ID: 18432587
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.