These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
285 related articles for article (PubMed ID: 20306444)
1. Comparison of the transpalpebral tonometer TGDc-01 with Goldmann applanation tonometry. Waisbourd M; Shemesh G; Top LB; Lazar M; Loewenstein A Eur J Ophthalmol; 2010; 20(5):902-6. PubMed ID: 20306444 [TBL] [Abstract][Full Text] [Related]
2. Measurement of the intraocular pressure with the "transpalpebral tonometer" TGDc-01 in comparison with applanation tonometry. Sandner D; Böhm A; Kostov S; Pillunat L Graefes Arch Clin Exp Ophthalmol; 2005 Jun; 243(6):563-9. PubMed ID: 15614540 [TBL] [Abstract][Full Text] [Related]
3. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
4. Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer. Saleh TA; Adams M; McDermott B; Claridge KG; Ewings P Clin Exp Ophthalmol; 2006 Aug; 34(6):516-20. PubMed ID: 16925697 [TBL] [Abstract][Full Text] [Related]
5. Transpalpebral measurement of intraocular pressure using the TGDc-01 tonometer versus standard Goldmann applanation tonometry. Lösch A; Scheuerle A; Rupp V; Auffarth G; Becker M Graefes Arch Clin Exp Ophthalmol; 2005 Apr; 243(4):313-6. PubMed ID: 15864620 [TBL] [Abstract][Full Text] [Related]
6. Transpalpebral measurement of intraocular pressure using the Diaton tonometer versus standard Goldmann applanation tonometry. Li Y; Shi J; Duan X; Fan F Graefes Arch Clin Exp Ophthalmol; 2010 Dec; 248(12):1765-70. PubMed ID: 20495818 [TBL] [Abstract][Full Text] [Related]
7. Variations of Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients With Corneal Edema After Phacoemulsification. Kiddee W; Tanjana A J Glaucoma; 2021 Apr; 30(4):317-324. PubMed ID: 33137014 [TBL] [Abstract][Full Text] [Related]
8. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851 [TBL] [Abstract][Full Text] [Related]
9. Comparison of the rebound tonometer with the Goldmann applanation tonometer in glaucoma patients. Sahin A; Niyaz L; Yildirim N Clin Exp Ophthalmol; 2007; 35(4):335-9. PubMed ID: 17539785 [TBL] [Abstract][Full Text] [Related]
10. Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects. Güler M; Bilak Ş; Bilgin B; Şimşek A; Çapkin M; Hakim Reyhan A J Glaucoma; 2015; 24(8):613-8. PubMed ID: 25264986 [TBL] [Abstract][Full Text] [Related]
11. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Francis BA; Hsieh A; Lai MY; Chopra V; Pena F; Azen S; Varma R; Ophthalmology; 2007 Jan; 114(1):20-6. PubMed ID: 17070592 [TBL] [Abstract][Full Text] [Related]
12. Influence of central corneal thickness on measured intraocular pressure differentials: Nidek RKT-7700, Topcon CT-80 NCTs and Goldmann Tonometer. Ogbuehi KC; Mucke S; Osuagwu UL Ophthalmic Physiol Opt; 2012 Nov; 32(6):547-55. PubMed ID: 23009324 [TBL] [Abstract][Full Text] [Related]
13. Effects of corneal thickness on intraocular pressure measured with three different tonometers. Murase H; Sawada A; Mochizuki K; Yamamoto T Jpn J Ophthalmol; 2009 Jan; 53(1):1-6. PubMed ID: 19184301 [TBL] [Abstract][Full Text] [Related]
14. Comparing applanation tonometry and rebound tonometry in glaucomatous and ocular hypertensive eyes. Marini M; Da Pozzo S; Accardo A; Canziani T Eur J Ophthalmol; 2011; 21(3):258-63. PubMed ID: 20890884 [TBL] [Abstract][Full Text] [Related]
15. Comparison of dynamic contour tonometry with goldman applanation tonometry over a wide range of central corneal thickness. Doyle A; Lachkar Y J Glaucoma; 2005 Aug; 14(4):288-92. PubMed ID: 15990609 [TBL] [Abstract][Full Text] [Related]
16. Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo. McCafferty S; Levine J; Schwiegerling J; Enikov ET BMC Ophthalmol; 2017 Nov; 17(1):215. PubMed ID: 29178849 [TBL] [Abstract][Full Text] [Related]
17. The effect of thin, thick, and normal corneas on Goldmann intraocular pressure measurements and correction formulae in individual eyes. Park SJ; Ang GS; Nicholas S; Wells AP Ophthalmology; 2012 Mar; 119(3):443-9. PubMed ID: 22035576 [TBL] [Abstract][Full Text] [Related]
18. Effect of central corneal thickness on intraocular pressure and comparison of Topcon CT-80 non-contact tonometry with Goldmann applanation tonometry. Mansoori T; Balakrishna N Clin Exp Optom; 2018 Mar; 101(2):206-212. PubMed ID: 29044716 [TBL] [Abstract][Full Text] [Related]