  • 1. Calibration issues for nanoindentation experiments: direct atomic force microscopy measurements and indirect methods.
    Barone AC; Salerno M; Patra N; Gastaldi D; Bertarelli E; Carnelli D; Vena P
    Microsc Res Tech; 2010 Oct; 73(10):996-1004. PubMed ID: 20306539
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A force-matching method for quantitative hardness measurements by atomic force microscopy with diamond-tipped sapphire cantilevers.
    Sansoz F; Gang T
    Ultramicroscopy; 2010 Dec; 111(1):11-9. PubMed ID: 21111262
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantitative measurement of indentation hardness and modulus of compliant materials by atomic force microscopy.
    Passeri D; Bettucci A; Biagioni A; Rossi M; Alippi A; Lucci M; Davoli I; Berezina S
    Rev Sci Instrum; 2008 Jun; 79(6):066105. PubMed ID: 18601441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Indentation modulus and hardness of viscoelastic thin films by atomic force microscopy: A case study.
    Passeri D; Bettucci A; Biagioni A; Rossi M; Alippi A; Tamburri E; Lucci M; Davoli I; Berezina S
    Ultramicroscopy; 2009 Nov; 109(12):1417-27. PubMed ID: 19674843
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An international round-robin calibration protocol for nanoindentation measurements.
    Cabibbo M; Ricci P; Cecchini R; Rymuza Z; Sullivan J; Dub S; Cohen S
    Micron; 2012 Feb; 43(2-3):215-22. PubMed ID: 21890366
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative nanotribology by AFM: a novel universal calibration platform.
    Tocha E; Schönherr H; Vancso GJ
    Langmuir; 2006 Feb; 22(5):2340-50. PubMed ID: 16489827
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atomic force microscopy and indentation force measurement of bone.
    Thurner PJ
    Wiley Interdiscip Rev Nanomed Nanobiotechnol; 2009; 1(6):624-49. PubMed ID: 20049821
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple atomic force microscopy calibration method for direct measurement of surface energy on nanostructured surfaces covered with molecularly thin liquid films.
    Brunner R; Etsion I; Talke FE
    Rev Sci Instrum; 2009 May; 80(5):055109. PubMed ID: 19485536
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A method to quantitatively measure the elastic modulus of materials in nanometer scale using atomic force microscopy.
    Tang B; Ngan AH; Pethica JB
    Nanotechnology; 2008 Dec; 19(49):495713. PubMed ID: 21730693
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical Behavior of Undoped n-Type GaAs under the Indentation of Berkovich and Flat-Tip Indenters.
    Xu L; Kong L; Zhao H; Wang S; Liu S; Qian L
    Materials (Basel); 2019 Apr; 12(7):. PubMed ID: 30979061
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of contact stiffness on wedge calibration of lateral force in atomic force microscopy.
    Wang F; Zhao X
    Rev Sci Instrum; 2007 Apr; 78(4):043701. PubMed ID: 17477664
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lateral force calibration: accurate procedures for colloidal probe friction measurements in atomic force microscopy.
    Chung KH; Pratt JR; Reitsma MG
    Langmuir; 2010 Jan; 26(2):1386-94. PubMed ID: 19827782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration of atomic force microscope cantilevers using piezolevers.
    Aksu SB; Turner JA
    Rev Sci Instrum; 2007 Apr; 78(4):043704. PubMed ID: 17477667
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lateral force microscope calibration using a modified atomic force microscope cantilever.
    Reitsma MG
    Rev Sci Instrum; 2007 Oct; 78(10):106102. PubMed ID: 17979458
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spring constant calibration of atomic force microscopy cantilevers with a piezosensor transfer standard.
    Langlois ED; Shaw GA; Kramar JA; Pratt JR; Hurley DC
    Rev Sci Instrum; 2007 Sep; 78(9):093705. PubMed ID: 17902953
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On elastic nanoindentation of coated half-spaces by point indenters of non-ideal shapes.
    Kindrachuk VM; Galanov BA; Kartuzov VV; Dub SN
    Nanotechnology; 2006 Feb; 17(4):1104-11. PubMed ID: 21727388
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of adhesion on the contact radius in atomic force microscopy indentation.
    Sirghi L; Rossi F
    Nanotechnology; 2009 Sep; 20(36):365702. PubMed ID: 19687552
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Size effects in nanoindentation of hard and soft surfaces.
    Alderighi M; Ierardi V; Fuso F; Allegrini M; Solaro R
    Nanotechnology; 2009 Jun; 20(23):235703. PubMed ID: 19451684
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Practical method to determine the effective zero-point of indentation depth for continuous stiffness measurement nanoindentation test with Berkovich tip.
    Geng D; Yu H; Okuno Y; Kondo S; Kasada R
    Sci Rep; 2022 Apr; 12(1):6391. PubMed ID: 35430627
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Elastic modulus measurements from individual lactose particles using atomic force microscopy.
    Perkins M; Ebbens SJ; Hayes S; Roberts CJ; Madden CE; Luk SY; Patel N
    Int J Pharm; 2007 Mar; 332(1-2):168-75. PubMed ID: 17074456
    [TBL] [Abstract][Full Text] [Related]  