These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Influence of time point of calibration on accuracy of continuous glucose monitoring in individuals with type 1 diabetes. Zueger T; Diem P; Mougiakakou S; Stettler C Diabetes Technol Ther; 2012 Jul; 14(7):583-8. PubMed ID: 22512266 [TBL] [Abstract][Full Text] [Related]
7. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Bode B; Gross K; Rikalo N; Schwartz S; Wahl T; Page C; Gross T; Mastrototaro J Diabetes Technol Ther; 2004 Apr; 6(2):105-13. PubMed ID: 15117576 [TBL] [Abstract][Full Text] [Related]
8. The accuracy of a new real-time continuous glucose monitoring algorithm: an analysis. Kovatchev B; Breton M J Diabetes Sci Technol; 2010 Jan; 4(1):119-22. PubMed ID: 20167175 [TBL] [Abstract][Full Text] [Related]
13. Modeling the error of continuous glucose monitoring sensor data: critical aspects discussed through simulation studies. Facchinetti A; Sparacino G; Cobelli C J Diabetes Sci Technol; 2010 Jan; 4(1):4-14. PubMed ID: 20167162 [TBL] [Abstract][Full Text] [Related]
14. Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities. Rodbard D Diabetes Technol Ther; 2016 Feb; 18 Suppl 2(Suppl 2):S3-S13. PubMed ID: 26784127 [TBL] [Abstract][Full Text] [Related]
15. Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring. McGarraugh G J Diabetes Sci Technol; 2010 Jan; 4(1):49-56. PubMed ID: 20167167 [TBL] [Abstract][Full Text] [Related]
16. Long-Term Home Study on Nocturnal Hypoglycemic Alarms Using a New Fully Implantable Continuous Glucose Monitoring System in Type 1 Diabetes. Wang X; Ioacara S; DeHennis A Diabetes Technol Ther; 2015 Nov; 17(11):780-6. PubMed ID: 26177299 [TBL] [Abstract][Full Text] [Related]
17. Benefits and limitations of continuous glucose monitoring in type 1 diabetes. Stone JY; Bailey TS Expert Rev Endocrinol Metab; 2020 Jan; 15(1):41-49. PubMed ID: 31928104 [No Abstract] [Full Text] [Related]
18. Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability. Joseph JI; Torjman MC; Strasma PJ J Diabetes Sci Technol; 2015 Jul; 9(4):725-38. PubMed ID: 26078254 [TBL] [Abstract][Full Text] [Related]
19. A semilogarithmic scale for glucose provides a balanced view of hyperglycemia and hypoglycemia. Rodbard D J Diabetes Sci Technol; 2009 Nov; 3(6):1395-401. PubMed ID: 20144394 [TBL] [Abstract][Full Text] [Related]
20. Performance comparison of the medtronic sof-sensor and enlite glucose sensors in inpatient studies of individuals with type 1 diabetes. Calhoun P; Lum J; Beck RW; Kollman C Diabetes Technol Ther; 2013 Sep; 15(9):758-61. PubMed ID: 23725474 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]