These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
61 related articles for article (PubMed ID: 2032335)
1. Secondary wavelength to use in the fructosamine test performed with Hitachi analyzers. Romay C; Armesto J; Pascual C Clin Chem; 1991 May; 37(5):762. PubMed ID: 2032335 [No Abstract] [Full Text] [Related]
2. Calibration of the fructosamine assay using albumin solutions glycated in vitro. Podzorski E; Wells FE Ann Clin Biochem; 1989 Nov; 26 ( Pt 6)():556-7. PubMed ID: 2619237 [No Abstract] [Full Text] [Related]
3. Nitroblue tetrazolium staining of serum fructosamine on agarose gel electrophoretograms. Romay C; Pascual C Clin Chem; 1987 Oct; 33(10):1949. PubMed ID: 3665075 [No Abstract] [Full Text] [Related]
4. Measurement of glycated albumin by the nitroblue tetrazolium colorimetric method. Mashiba S; Uchida K; Okuda S; Tomita S Clin Chim Acta; 1992 Nov; 212(1-2):3-15. PubMed ID: 1486680 [TBL] [Abstract][Full Text] [Related]
5. A 10-min pre-incubation is required for measurement of fructosamine in plasma. Seng LY; Staley MJ Clin Chem; 1986 Feb; 32(2):403-4. PubMed ID: 3943218 [No Abstract] [Full Text] [Related]
14. Chemistry of the fructosamine assay: D-glucosone is the product of oxidation of Amadori compounds. Baker JR; Zyzak DV; Thorpe SR; Baynes JW Clin Chem; 1994 Oct; 40(10):1950-5. PubMed ID: 7923778 [TBL] [Abstract][Full Text] [Related]
15. [The determination of the reference range and the reference limits of the fructosamine test]. Krantz S; Lober M; Lober S Z Med Lab Diagn; 1989; 30(7):395-6. PubMed ID: 2603462 [No Abstract] [Full Text] [Related]
16. Effect of albumin and detergent on the reduction of NBT by 1-deoxy-1-morpholinofructose. Podzorski E; Wells FE Ann Clin Biochem; 1989 Nov; 26 ( Pt 6)():496-9. PubMed ID: 2619229 [TBL] [Abstract][Full Text] [Related]
18. [Comparison of the results of the fructosamine test done by two unrelated laboratories]. Krantz S; Fiedler H; Lober M; Lober S; Fiedler M Z Med Lab Diagn; 1989; 30(7):397-8. PubMed ID: 2603463 [No Abstract] [Full Text] [Related]
19. Effect of measurement wavelength on fructosamine results. Rowbury D; Farrance I; Fitzgerald A Clin Chem; 1989 Jul; 35(7):1552. PubMed ID: 2758615 [No Abstract] [Full Text] [Related]
20. Fructosamine and IgA: no correlation in non-diabetics. Llyod DR; Marples J Clin Chem; 1989 Jul; 35(7):1556-7. PubMed ID: 2758621 [No Abstract] [Full Text] [Related] [Next] [New Search]