BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 20337062)

  • 21. Evaluation of cytotoxicity of UHMWPE wear debris.
    Rao S; Shirata K; Furukawa KS; Ushida T; Tateishi T; Kanazawa M; Katsube S; Janna S
    Biomed Mater Eng; 1999; 9(4):209-17. PubMed ID: 10674175
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Sodium-azide versus ProClin 300: influence on the morphology of UHMWPE particles generated in laboratory tests.
    Affatato S; Bersaglia G; Emiliani D; Foltran I; Toni A
    Biomaterials; 2004 Feb; 25(5):835-42. PubMed ID: 14609672
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effect of patient gait on the material properties of UHMWPE in hip replacements.
    Davey SM; Orr JF; Buchanan FJ; Nixon JR; Bennett D
    Biomaterials; 2005 Aug; 26(24):4993-5001. PubMed ID: 15769535
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-term performance and wear of ultrahigh-molecular-weight polyethylene in total joint replacement prostheses: a brief overview and perspective.
    Gunther J; Rose RM
    J Long Term Eff Med Implants; 1994; 4(4):157-75. PubMed ID: 10155138
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.
    Langton DJ; Joyce TJ; Jameson SS; Lord J; Van Orsouw M; Holland JP; Nargol AV; De Smet KA
    J Bone Joint Surg Br; 2011 Feb; 93(2):164-71. PubMed ID: 21282753
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis.
    Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC
    Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect on wear of lift-off in total knee arthroplasty.
    Todo S; Blunn GW; Harrison M; Freeman MA
    Biomed Mater Eng; 2003; 13(3):231-4. PubMed ID: 12883172
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reduction of wear volume from ultrahigh molecular weight polyethylene knee components by the addition of vitamin E.
    Teramura S; Sakoda H; Terao T; Endo MM; Fujiwara K; Tomita N
    J Orthop Res; 2008 Apr; 26(4):460-4. PubMed ID: 17975842
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty? A double-blind, randomized, and controlled trial using roentgen stereophotogrammetric analysis.
    Glyn-Jones S; Isaac S; Hauptfleisch J; McLardy-Smith P; Murray DW; Gill HS
    J Arthroplasty; 2008 Apr; 23(3):337-43. PubMed ID: 18358369
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator.
    Firkins PJ; Tipper JL; Saadatzadeh MR; Ingham E; Stone MH; Farrar R; Fisher J
    Biomed Mater Eng; 2001; 11(2):143-57. PubMed ID: 11352113
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Finite element simulation of early creep and wear in total hip arthroplasty.
    Bevill SL; Bevill GR; Penmetsa JR; Petrella AJ; Rullkoetter PJ
    J Biomech; 2005 Dec; 38(12):2365-74. PubMed ID: 16214484
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Wear in the prosthetic shoulder: association with design parameters.
    Hopkins AR; Hansen UN; Amis AA; Knight L; Taylor M; Levy O; Copeland SA
    J Biomech Eng; 2007 Apr; 129(2):223-30. PubMed ID: 17408327
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Total hip wear assessment: a comparison between computational and in vitro wear assessment techniques using ISO 14242 loading and kinematics.
    Matsoukas G; Willing R; Kim IY
    J Biomech Eng; 2009 Apr; 131(4):041011. PubMed ID: 19275440
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The basis for a second-generation highly cross-linked UHMWPE.
    Dumbleton JH; D'Antonio JA; Manley MT; Capello WN; Wang A
    Clin Orthop Relat Res; 2006 Dec; 453():265-71. PubMed ID: 17016228
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.
    Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J
    J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797
    [TBL] [Abstract][Full Text] [Related]  

  • 36. An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact.
    Ohashi M; Tomita N; Ikada Y; Ikeuchi K; Motoike T
    Biomed Mater Eng; 1996; 6(6):441-51. PubMed ID: 9138654
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The influence of design, materials and kinematics on the in vitro wear of total knee replacements.
    McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J
    J Biomech; 2005 Feb; 38(2):357-65. PubMed ID: 15598464
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Polyethylene wear in periprosthetic tissue of failed cemented total hip arthroplasties].
    Wang Y; Dai K; Zhang P
    Zhonghua Wai Ke Za Zhi; 1997 Aug; 35(8):459-61. PubMed ID: 10678063
    [TBL] [Abstract][Full Text] [Related]  

  • 40. In vivo wear rate of the Birmingham Hip Resurfacing arthroplasty. A review of 10 retrieved components.
    Witzleb WC; Hanisch U; Ziegler J; Guenther KP
    J Arthroplasty; 2009 Sep; 24(6):951-6. PubMed ID: 18757168
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.