These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. Metrology to quantify wear and creep of polyethylene tibial knee inserts. Muratoglu OK; Perinchief RS; Bragdon CR; O'Connor DO; Konrad R; Harris WH Clin Orthop Relat Res; 2003 May; (410):155-64. PubMed ID: 12771826 [TBL] [Abstract][Full Text] [Related]
7. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis. Oonishi H; Ueno M; Kim SC; Oonishi H; Iwamoto M; Kyomoto M J Arthroplasty; 2009 Apr; 24(3):374-82. PubMed ID: 18524533 [TBL] [Abstract][Full Text] [Related]
8. Highly crosslinked polyethylene in posterior-stabilized total knee arthroplasty: in vitro performance evaluation of wear, delamination, and tibial post durability. Stoller AP; Johnson TS; Popoola OO; Humphrey SM; Blanchard CR J Arthroplasty; 2011 Apr; 26(3):483-91. PubMed ID: 20413249 [TBL] [Abstract][Full Text] [Related]
9. Surface extraction can provide a reference for micro-CT analysis of retrieved total knee implants. Teeter MG; Milner JS; Naudie DD; MacDonald SJ Knee; 2014 Aug; 21(4):801-5. PubMed ID: 24853191 [TBL] [Abstract][Full Text] [Related]
10. Measurements of surface and subsurface damage in retrieved polyethylene tibial inserts of a contemporary design. Teeter MG; Brandt JM; Naudie DD; Bohm ER; McCalden RW; Holdsworth DW J Long Term Eff Med Implants; 2012; 22(1):21-31. PubMed ID: 23016787 [TBL] [Abstract][Full Text] [Related]
11. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement. Affatato S; Cristofolini L; Leardini W; Erani P; Zavalloni M; Tigani D; Viceconti M Artif Organs; 2008 Dec; 32(12):942-8. PubMed ID: 19133022 [TBL] [Abstract][Full Text] [Related]
13. [Research progress of polyethylene inserts wear measurement and evaluation in total knee arthroplasty]. Zhao F; Wang C; Fan Y Zhongguo Yi Liao Qi Xie Za Zhi; 2015 Jan; 39(1):33-6. PubMed ID: 26027291 [TBL] [Abstract][Full Text] [Related]
14. Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulation. Harman MK; DesJardins J; Benson L; Banks SA; LaBerge M; Hodge WA J Orthop Res; 2009 Apr; 27(4):540-8. PubMed ID: 18932244 [TBL] [Abstract][Full Text] [Related]
18. Material and surface factors influencing backside fretting wear in total knee replacement tibial components. Billi F; Sangiorgio SN; Aust S; Ebramzadeh E J Biomech; 2010 May; 43(7):1310-5. PubMed ID: 20172525 [TBL] [Abstract][Full Text] [Related]