1. [Comparative study of G8 glycated haemoglobin testing system and the Integra 800 immunoassay]. Szymanowicz A; Neyron MJ Ann Biol Clin (Paris); 2010; 68(2):227-33. PubMed ID: 20348050 [TBL] [Abstract][Full Text] [Related]
2. [Evaluation of HBA1C measurement on Architect CI8200 (Abbott Diagnostic). Comparison with HPLC D-10 Bio-Rad assay]. Beaune G; Ducruet J; Jund J; Favre S Ann Biol Clin (Paris); 2009; 67(1):101-7. PubMed ID: 19189890 [TBL] [Abstract][Full Text] [Related]
3. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100]. Lee JY; Hong KS; Cho SE Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705 [TBL] [Abstract][Full Text] [Related]
4. Comparison of IFCC-calibrated HbA(1c) from laboratory and point of care testing systems. Manley SE; Hikin LJ; Round RA; Manning PW; Luzio SD; Dunseath GJ; Nightingale PG; Stratton IM; Cramb R; Sikaris KA; Gough SC; Webber J Diabetes Res Clin Pract; 2014 Sep; 105(3):364-72. PubMed ID: 24985893 [TBL] [Abstract][Full Text] [Related]
5. Classification of variant forms of haemoglobin according to the ratio of glycated haemoglobin to glycated albumin. Miyazaki A; Kohzuma T; Kasayama S; Koga M Ann Clin Biochem; 2012 Sep; 49(Pt 5):441-4. PubMed ID: 22715294 [TBL] [Abstract][Full Text] [Related]
6. Analytical evaluation of the Bio-Rad variant II automated HbA(1C) analyzer. Higgins TN; Blakney GB; Dayton J Clin Biochem; 2001 Jul; 34(5):361-5. PubMed ID: 11522271 [TBL] [Abstract][Full Text] [Related]
7. Effects of hemoglobin (Hb) E and HbD traits on measurements of glycated Hb (HbA1c) by 23 methods. Little RR; Rohlfing CL; Hanson S; Connolly S; Higgins T; Weykamp CW; D'Costa M; Luzzi V; Owen WE; Roberts WL Clin Chem; 2008 Aug; 54(8):1277-82. PubMed ID: 18556332 [TBL] [Abstract][Full Text] [Related]
8. Performance evaluation of the glycated hemoglobin A1c analyzer for point-of-care testing compared with laboratory-based devices: a multicenter validation study. Zhou Y; Yang F; Zhou M; Pan B; Wang B; Guo W; Shao W; Zhu J Scand J Clin Lab Invest; 2024 Sep; 84(5):356-361. PubMed ID: 39217618 [TBL] [Abstract][Full Text] [Related]
9. [Interference of hemoglobin variants on glycated hemoglobin measurement using Architect ci8200 immunoassay (Abbott Diagnostics)]. Succari M; Fonfrede M; Laguillier C; Wang J; Siguret V; Beaudeux JL Ann Biol Clin (Paris); 2009; 67(5):557-62. PubMed ID: 19789128 [TBL] [Abstract][Full Text] [Related]
10. Analytical evaluation of hemoglobin A(1c) dual kit assay on Bio-Rad Variant II: an automated HPLC hemoglobin analyzer for the management of diabetic patients. Moridani MY; Verjee Z; Allen LC Clin Biochem; 2003 Jun; 36(4):317-20. PubMed ID: 12810162 [TBL] [Abstract][Full Text] [Related]
11. Comparative Analytical Performance of Various HbA1c Assays in Iran. Razi F; Rahnamaye Farzami M; Ebrahimi SA; Nahid M; Bigdeli MG; Sheidaei A; Ghasemian A; Tootee A; Keramati T; Nasli Esfahani E; Larijani B; Pasalar P Arch Iran Med; 2016 Jun; 19(6):414-9. PubMed ID: 27293057 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of turbidimetric inhibition immunoassay (TINIA) and HPLC methods for glycated haemoglobin determination. Genc S; Omer B; Aycan-Ustyol E; Ince N; Bal F; Gurdol F J Clin Lab Anal; 2012 Nov; 26(6):481-5. PubMed ID: 23143632 [TBL] [Abstract][Full Text] [Related]
14. Verification of a novel point-of-care HbA Wang Y; Peng W; Tang J; Dong L; Gu C; Zhang X; Zhou J; Jia W Biochem Med (Zagreb); 2018 Jun; 28(2):020705. PubMed ID: 29666558 [TBL] [Abstract][Full Text] [Related]
15. Comparison of Turbidimetric Inhibition Immunoassay, High-Performance Liquid Chromatography, and Capillary Electrophoresis Methods for Glycated Hemoglobin Determination. Gilani M; Aamir M; Akram A; Haroon ZH; Ijaz A; Khadim MT Lab Med; 2020 Nov; 51(6):579-584. PubMed ID: 32219342 [TBL] [Abstract][Full Text] [Related]
16. Best use of the recommended IFCC reference method, material and values in HbA1C analyses. Penttilä IM; Halonen T; Punnonen K; Tiikkainen U Scand J Clin Lab Invest; 2005; 65(6):453-62. PubMed ID: 16179278 [TBL] [Abstract][Full Text] [Related]
17. Performance characteristics and clinical utility of an enzymatic method for the measurement of glycated albumin in plasma. Paroni R; Ceriotti F; Galanello R; Battista Leoni G; Panico A; Scurati E; Paleari R; Chemello L; Quaino V; Scaldaferri L; Lapolla A; Mosca A Clin Biochem; 2007 Dec; 40(18):1398-405. PubMed ID: 17919531 [TBL] [Abstract][Full Text] [Related]
18. [Evaluation of Variant II analyzer equipped with the new 270-2101 NU kit (Bio-Rad) for HbA 1c assay]. Lavalard E; Szymezak J; Leroy N; Gillery P Ann Biol Clin (Paris); 2009; 67(1):55-65. PubMed ID: 19189886 [TBL] [Abstract][Full Text] [Related]
19. [Evaluation of the new kit HbA(1c) Analyzer 2.0 Variant II Turbo (Bio-Rad)]. Meurice J; Guillard E; Jaisson S; Leroy N; Gillery P Ann Biol Clin (Paris); 2011; 69(5):561-9. PubMed ID: 22008136 [TBL] [Abstract][Full Text] [Related]
20. Advantage of HbA1c assay by HPLC D-10 versus cobas integra 400 in a population carrier for HbS and HbC. Bouzid K; Bahlous A; Ferjani W; Kalai E; Ducrocq R; Ben Mami F; Abdelmoula J Clin Lab; 2012; 58(7-8):821-8. PubMed ID: 22997985 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]