359 related articles for article (PubMed ID: 20350770)
21. Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement.
Park JB; Hwang IC; Lee W; Han JK; Kim CH; Lee SP; Yang HM; Park EA; Kim HK; Chiam PTL; Kim YJ; Koo BK; Sohn DW; Ahn H; Kang JW; Park SJ; Kim HS
Int J Cardiol; 2018 May; 259():60-68. PubMed ID: 29472027
[TBL] [Abstract][Full Text] [Related]
22. Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation.
Haensig M; Lehmkuhl L; Rastan AJ; Kempfert J; Mukherjee C; Gutberlet M; Holzhey DM; Mohr FW
Eur J Cardiothorac Surg; 2012 Jun; 41(6):1234-40; discussion 1240-1. PubMed ID: 22241002
[TBL] [Abstract][Full Text] [Related]
23. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence.
Détaint D; Lepage L; Himbert D; Brochet E; Messika-Zeitoun D; Iung B; Vahanian A
JACC Cardiovasc Interv; 2009 Sep; 2(9):821-7. PubMed ID: 19778769
[TBL] [Abstract][Full Text] [Related]
24. Predictors of 1-year mortality in patients with aortic regurgitation after transcatheter aortic valve implantation: an analysis from the multicentre German TAVI registry.
Abdel-Wahab M; Zahn R; Gerckens U; Linke A; Sievert H; Schäfer U; Kahlert P; Hambrecht R; Sack S; Hoffmann E; Senges J; Schneider S; Richardt G;
Heart; 2014 Aug; 100(16):1250-6. PubMed ID: 24895354
[TBL] [Abstract][Full Text] [Related]
25. Evaluation of aortic regurgitation after transcatheter aortic valve implantation: aortic root angiography in comparison to cardiac magnetic resonance.
Frick M; Meyer CG; Kirschfink A; Altiok E; Lehrke M; Brehmer K; Lotfi S; Hoffmann R
EuroIntervention; 2016 Mar; 11(12):1419-27. PubMed ID: 25772902
[TBL] [Abstract][Full Text] [Related]
26. Impact of aortic regurgitation after transcatheter aortic valve implantation: results from the REVIVAL trial.
Yared K; Garcia-Camarero T; Fernandez-Friera L; Llano M; Durst R; Reddy AA; O'Neill WW; Picard MH
JACC Cardiovasc Imaging; 2012 May; 5(5):469-77. PubMed ID: 22595154
[TBL] [Abstract][Full Text] [Related]
27. Impact of aortic valve calcification on the outcome of transcatheter aortic valve implantation: results from the prospective multicenter German TAVI registry.
Staubach S; Franke J; Gerckens U; Schuler G; Zahn R; Eggebrecht H; Hambrecht R; Sack S; Richardt G; Horack M; Senges J; Steinberg DH; Ledwoch J; Fichtlscherer S; Doss M; Wunderlich N; Sievert H;
Catheter Cardiovasc Interv; 2013 Feb; 81(2):348-55. PubMed ID: 22566406
[TBL] [Abstract][Full Text] [Related]
28. Clinical impact of aortic regurgitation after transcatheter aortic valve replacement: insights into the degree and acuteness of presentation.
Jerez-Valero M; Urena M; Webb JG; Tamburino C; Munoz-Garcia AJ; Cheema A; Dager AE; Serra V; Amat-Santos IJ; Barbanti M; Immè S; Alonso Briales JH; Al Lawati H; Benitez LM; Cucalon AM; Garcia del Blanco B; Revilla A; Dumont E; Barbosa Ribeiro H; Nombela-Franco L; Bergeron S; Pibarot P; Rodés-Cabau J
JACC Cardiovasc Interv; 2014 Sep; 7(9):1022-32. PubMed ID: 25234675
[TBL] [Abstract][Full Text] [Related]
29. Morphological Characteristics and Calcification of the Native Aortic Valve and the Relation to Significant Aortic Regurgitation after CoreValve TAVI.
Bosmans B; Collas V; Verhoelst E; Paelinck B; Vander Sloten J; Bosmans J
J Heart Valve Dis; 2016 Jul; 25(4):410-416. PubMed ID: 28009942
[TBL] [Abstract][Full Text] [Related]
30. Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation.
Buzzatti N; Maisano F; Latib A; Cioni M; Taramasso M; Mussardo M; Colombo A; Alfieri O
Eur J Cardiothorac Surg; 2013 Jan; 43(1):43-50; discussion 50-1. PubMed ID: 22551969
[TBL] [Abstract][Full Text] [Related]
31. Transcatheter aortic valve implantation of a second-generation valve for pure aortic regurgitation: procedural outcome, haemodynamic data and follow-up.
Schlingloff F; Schäfer U; Frerker C; Schmoeckel M; Bader R
Interact Cardiovasc Thorac Surg; 2014 Sep; 19(3):388-93. PubMed ID: 24893871
[TBL] [Abstract][Full Text] [Related]
32. Aortic regurgitation after transcatheter aortic valve implantation of the Edwards SAPIEN ™ valve.
Nielsen HH; Egeblad H; Andersen HR; Thuesen L; Poulsen SH; Klaaborg KE; Jakobsen CJ; Hjortdal VE
Scand Cardiovasc J Suppl; 2013 Feb; 47(1):36-41. PubMed ID: 22989057
[TBL] [Abstract][Full Text] [Related]
33. Aortic valve calcification is subject to aortic stenosis severity and the underlying flow pattern.
Veulemans V; Piayda K; Maier O; Bosbach G; Polzin A; Hellhammer K; Afzal S; Klein K; Dannenberg L; Zako S; Jung C; Westenfeld R; Kelm M; Zeus T
Heart Vessels; 2021 Feb; 36(2):242-251. PubMed ID: 32894344
[TBL] [Abstract][Full Text] [Related]
34. Impact of device landing zone calcification on paravalvular regurgitation after transcatheter aortic valve replacement: a real-time three-dimensional transesophageal echocardiographic study.
Mihara H; Shibayama K; Berdejo J; Harada K; Itabashi Y; Siegel RJ; Kashif M; Jilaihawi H; Makkar RR; Shiota T
J Am Soc Echocardiogr; 2015 Apr; 28(4):404-14. PubMed ID: 25560483
[TBL] [Abstract][Full Text] [Related]
35. Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement.
Crouch G; Tully PJ; Bennetts J; Sinhal A; Bradbrook C; Penhall AL; De Pasquale CG; Baker RA; Selvanayagam JB
J Cardiovasc Magn Reson; 2015 May; 17(1):32. PubMed ID: 25953135
[TBL] [Abstract][Full Text] [Related]
36. Caseous calcification of the left aortic valve cusp.
Schouver ED; Lena D; Paul G; Mihoubi A; Lopez S
J Card Surg; 2017 Jul; 32(7):418-419. PubMed ID: 28689373
[No Abstract] [Full Text] [Related]
37. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation.
Altiok E; Frick M; Meyer CG; Al Ateah G; Napp A; Kirschfink A; Almalla M; Lotfi S; Becker M; Herich L; Lehmacher W; Hoffmann R
Am J Cardiol; 2014 Jun; 113(11):1859-66. PubMed ID: 24837265
[TBL] [Abstract][Full Text] [Related]
38. Video densitometric assessment of aortic regurgitation after transcatheter aortic valve implantation: results from the Brazilian TAVI registry.
Tateishi H; Campos CM; Abdelghani M; Leite RS; Mangione JA; Bary L; Soliman OI; Spitzer E; Perin MA; Onuma Y; Serruys PW; Lemos PA; Brito FS
EuroIntervention; 2016 Mar; 11(12):1409-18. PubMed ID: 26999681
[TBL] [Abstract][Full Text] [Related]
39. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
Patsalis PC; Al-Rashid F; Neumann T; Plicht B; Hildebrandt HA; Wendt D; Thielmann M; Jakob HG; Heusch G; Erbel R; Kahlert P
JACC Cardiovasc Interv; 2013 Sep; 6(9):965-71. PubMed ID: 24050862
[TBL] [Abstract][Full Text] [Related]
40. Initial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.
Seiffert M; Bader R; Kappert U; Rastan A; Krapf S; Bleiziffer S; Hofmann S; Arnold M; Kallenbach K; Conradi L; Schlingloff F; Wilbring M; Schäfer U; Diemert P; Treede H
JACC Cardiovasc Interv; 2014 Oct; 7(10):1168-74. PubMed ID: 25129672
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]