These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 20351227)
1. Review of adverse events associated with false glucose readings measured by GDH-PQQ-based glucose test strips in the presence of interfering sugars. Frias JP; Lim CG; Ellison JM; Montandon CM Diabetes Care; 2010 Apr; 33(4):728-9. PubMed ID: 20351227 [TBL] [Abstract][Full Text] [Related]
2. False elevation of blood glucose levels measured by GDH-PQQ-based glucometers occurs during all daily dwells in peritoneal dialysis patients using icodextrin. Tsai CY; Lee SC; Hung CC; Lee JJ; Kuo MC; Hwang SJ; Chen HC Perit Dial Int; 2010; 30(3):329-35. PubMed ID: 20190030 [TBL] [Abstract][Full Text] [Related]
3. Erroneously elevated glucose values due to maltose interference in mutant glucose dehydrogenase pyrroloquinolinequinone (mutant GDH-PQQ) based glucometer. Chakraborty PP; Patra S; Bhattacharjee R; Chowdhury S BMJ Case Rep; 2017 May; 2017():. PubMed ID: 28500115 [TBL] [Abstract][Full Text] [Related]
4. Falsely Elevated Glucose Concentrations in Peritoneal Dialysis Patients Using Icodextrin. Dogan K; Kayalp D; Ceylan G; Azak A; Senes M; Duranay M; Yucel D J Clin Lab Anal; 2016 Sep; 30(5):506-9. PubMed ID: 26511081 [TBL] [Abstract][Full Text] [Related]
5. [False measurement of glucose during dialysis with icodextrin]. Husøy AM; Knudsen GR; Thierley M; Svarstad E Tidsskr Nor Laegeforen; 2006 Sep; 126(17):2268-70. PubMed ID: 16967067 [TBL] [Abstract][Full Text] [Related]
6. Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems. Schleis TG Pharmacotherapy; 2007 Sep; 27(9):1313-21. PubMed ID: 17723085 [TBL] [Abstract][Full Text] [Related]
7. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview. Floré KM; Delanghe JR Perit Dial Int; 2009; 29(4):377-83. PubMed ID: 19602602 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of blood glucose levels after hepatitis B immune globulin administration utilizing two different blood glucose monitoring systems. Shetty K; Lukose T; Brown RS Transplant Proc; 2010 Dec; 42(10):4123-6. PubMed ID: 21168642 [TBL] [Abstract][Full Text] [Related]
9. Urine glucose testing in the critically ill: a comparison of two enzymatic test strips. Zaloga GP; Chernow B; McFadden E; Soldano S; Lyons P; O'Brian JT Crit Care Med; 1984 Mar; 12(3):188-90. PubMed ID: 6697742 [TBL] [Abstract][Full Text] [Related]
10. Effect of adverse storage conditions on performance of glucometer test strips. Bamberg R; Schulman K; MacKenzie M; Moore J; Olchesky S Clin Lab Sci; 2005; 18(4):203-9. PubMed ID: 16315736 [TBL] [Abstract][Full Text] [Related]
11. [Occult hypoglycaemia in patient with chronic kidney failure and chronic ambulatory peritoneal dialysis]. de Lange S; Fernández Cabrera J; Gomar Vidal S Med Intensiva; 2011 Mar; 35(2):133-4. PubMed ID: 21215492 [No Abstract] [Full Text] [Related]
12. Erroneous glucose recordings while using mutant variant of quinoprotein glucose dehydrogenase glucometer in a child with galactosemia. Mathew V; Ramakrishnan A; Srinivasan R; Sushma K; Bantwal G; Ayyar V Indian J Endocrinol Metab; 2013 Oct; 17(Suppl 1):S289-91. PubMed ID: 24251189 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of reagent strips in detecting hypoglycemia in the emergency department. Scott PA; Wolf LR; Spadafora MP Ann Emerg Med; 1998 Sep; 32(3 Pt 1):305-9. PubMed ID: 9737491 [TBL] [Abstract][Full Text] [Related]
14. Test strips for blood glucose monitors are not always accurate. Melker RJ Diabetes Care; 2003 Nov; 26(11):3190. PubMed ID: 14578265 [No Abstract] [Full Text] [Related]
15. Maltose interference-free test strips for blood glucose testing at point-of-care: a laboratory performance evaluation. Ng WY; Tiong CC; Jacob E Diabetes Technol Ther; 2010 Nov; 12(11):889-93. PubMed ID: 20879959 [TBL] [Abstract][Full Text] [Related]
16. Self-monitoring of blood glucose in Type 2 diabetes: cross-sectional analyses in 1993, 1999 and 2009. Evans JM; Mackison D; Emslie-Smith A; Lawton J Diabet Med; 2012 Jun; 29(6):792-5. PubMed ID: 22587406 [TBL] [Abstract][Full Text] [Related]
17. Interference of home blood glucose measurements and poor outcomes: a solvable problem requiring broader exposure. Hirsch IB; Verderese CA Diabetes Technol Ther; 2010 Mar; 12(3):245-7. PubMed ID: 20136404 [No Abstract] [Full Text] [Related]
18. A prospective evaluation of glucose reagent teststrips in the prehospital setting. Lavery RF; Allegra JR; Cody RP; Zacharias D; Schreck DM Am J Emerg Med; 1991 Jul; 9(4):304-8. PubMed ID: 2053998 [TBL] [Abstract][Full Text] [Related]
19. [Can ascorbic acid and acetylsalicylic acid distort the results of blood sugar test strips?]. Koschinsky T Dtsch Med Wochenschr; 2003 May; 128(21):1189. PubMed ID: 12761694 [No Abstract] [Full Text] [Related]