115 related articles for article (PubMed ID: 2036189)
1. Aerodynamic properties of the low-resistance Groningen button.
Zijlstra RJ; Mahieu HF; van Lith-Bijl JT; Schutte HK
Arch Otolaryngol Head Neck Surg; 1991 Jun; 117(6):657-61. PubMed ID: 2036189
[TBL] [Abstract][Full Text] [Related]
2. The ultra-low resistance Groningen voice prosthesis: aerodynamic properties.
Chung RP; Geskus J; Mahieu HF
Rev Laryngol Otol Rhinol (Bord); 1999; 120(4):245-8. PubMed ID: 10668359
[TBL] [Abstract][Full Text] [Related]
3. Clinical experience with the low-resistance Groningen button.
van Lith-Bijl JT; Mahieu HF; Patel P; Zijlstra RJ
Eur Arch Otorhinolaryngol; 1992; 249(6):354-7. PubMed ID: 1418948
[TBL] [Abstract][Full Text] [Related]
4. In vitro measurements of aerodynamic characteristics of an improved tracheostoma valve for laryngectomees.
Geertsema AA; de Vries MP; Schutte HK; Lubbers J; Verkerke GJ
Eur Arch Otorhinolaryngol; 1998; 255(5):244-9. PubMed ID: 9638466
[TBL] [Abstract][Full Text] [Related]
5. Experience with Barton button and peristomal breathing valve attachments for hands-free tracheoesophageal speech.
Lewin JS; Lemon J; Bishop-Leone JK; Leyk S; Martin JW; Gillenwater AM
Head Neck; 2000 Mar; 22(2):142-8. PubMed ID: 10679901
[TBL] [Abstract][Full Text] [Related]
6. Further experience with modification of an intraluminal button for hands-free tracheoesophageal speech after laryngectomy.
Lewin JS; Montgomery PC; Hutcheson KA; Chambers MS
J Prosthet Dent; 2009 Nov; 102(5):328-31. PubMed ID: 19853175
[TBL] [Abstract][Full Text] [Related]
7. Modification of the Barton button for tracheoesophageal speech: an innovative maxillofacial prosthetic technique.
Lemon JC; Lewin JS; Chambers MS; Martin JW
J Prosthet Dent; 2002 Feb; 87(2):236-9. PubMed ID: 11854684
[TBL] [Abstract][Full Text] [Related]
8. Aerodynamic and sound intensity measurements in tracheoesophageal voice.
Grolman W; Eerenstein SE; Tan FM; Tange RA; Schouwenburg PF
ORL J Otorhinolaryngol Relat Spec; 2007; 69(2):68-76. PubMed ID: 17127821
[TBL] [Abstract][Full Text] [Related]
9. In vitro and in vivo comparison of the low-resistance Groningen and the Provox tracheosophageal voice prostheses.
Chung RP; Patel P; Ter Keurs M; Van Lith Bijl JT; Mahieu HF
Rev Laryngol Otol Rhinol (Bord); 1998; 119(5):301-6. PubMed ID: 10089797
[TBL] [Abstract][Full Text] [Related]
10. In vitro leakage susceptibility of tracheoesophageal shunt prostheses in the absence and presence of a biofilm.
Oosterhof JJ; van der Mei HC; Busscher HJ; Free RH; Kaper HJ; van Weissenbruch R; Albers FW
J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):23-8. PubMed ID: 15660395
[TBL] [Abstract][Full Text] [Related]
11. [Voice rehabilitation following larynx extirpation using the Groningen button].
Rosingh HJ; Mahieu HF; Annyas AA; Schutte HK; Goorhuis-Brouwer SM
Ned Tijdschr Geneeskd; 1991 Jul; 135(29):1315-8. PubMed ID: 1865934
[TBL] [Abstract][Full Text] [Related]
12. Aerodynamics of esophageal voice production with and without a Groningen voice prosthesis.
Schutte HK; Nieboer GJ
Folia Phoniatr Logop; 2002; 54(1):8-18. PubMed ID: 11901261
[TBL] [Abstract][Full Text] [Related]
13. The ultra-low resistance Groningen voice prosthesis: clinical experiences.
Chung RP; Dagli AS; Geskus J; de Bruin MD; Mahieu HF
Rev Laryngol Otol Rhinol (Bord); 2001; 122(2):129-33. PubMed ID: 11715263
[TBL] [Abstract][Full Text] [Related]
14. Aerodynamic studies of laryngectomees after the Amatsu tracheoesophageal shunt operation.
Kinishi M; Amatsu M
Ann Otol Rhinol Laryngol; 1986; 95(2 Pt 1):181-4. PubMed ID: 3963691
[TBL] [Abstract][Full Text] [Related]
15. Characteristics of Groningen tracheo-oesophageal speaking valves prior to insertion and after removal for failure.
Parker AJ; Stevens JC; Wickham MH; Clegg RT
J Laryngol Otol; 1992 Jun; 106(6):521-4. PubMed ID: 1624888
[TBL] [Abstract][Full Text] [Related]
16. Prosthetic vocal rehabilitation in laryngectomees using the Groningen prosthesis.
Van de Heyning P; Claes S; Van Laer C; Kochelhoren E
Acta Otorhinolaryngol Ital; 1988; 8 Suppl 20():117-21. PubMed ID: 3073628
[No Abstract] [Full Text] [Related]
17. [Aerodynamic study of the low-resistance Groningen button in voice prosthesis].
Liu JX; Hu M; Du JQ; Zhang BZ
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2007 Aug; 42(8):589-93. PubMed ID: 17944207
[TBL] [Abstract][Full Text] [Related]
18. In vivo aerodynamic characteristics of the Nijdam voice prosthesis.
Van den Hoogen FJ; Veenstra A; Verkerke GJ; Schutte HK; Manni JJ
Acta Otolaryngol; 1997 Nov; 117(6):897-902. PubMed ID: 9442834
[TBL] [Abstract][Full Text] [Related]
19. [Tracheostoma valve with integrated cough lid for improvement of hands-free speech in laryngectomees - long term results].
Schwarz Ch; Cirugeda-Kühnert M; Hagen R
Laryngorhinootologie; 2004 Mar; 83(3):173-9. PubMed ID: 15042482
[TBL] [Abstract][Full Text] [Related]
20. [Experiences with the Groningen voice prosthesis after laryngectomy].
Manni JJ; van den Hoogen FJ; Oudes M
HNO; 1994 Jun; 42(6):358-61. PubMed ID: 8071096
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]