These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 20362767)

  • 1. Comparison of clasp retention on enamel and composite resin-recontoured abutments following repeated removal in vitro.
    Zarrati S; Sadighpour L; Jahanian G
    J Prosthet Dent; 2010 Apr; 103(4):240-4. PubMed ID: 20362767
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of long-term simulated RPD clasp attachment/detachment on retention loss and wear for two clasp types and three abutment material surfaces.
    Helal MA; Baraka OA; Sanad ME; Ludwig K; Kern M
    J Prosthodont; 2012 Jul; 21(5):370-7. PubMed ID: 22443158
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.
    Arda T; Arikan A
    J Prosthet Dent; 2005 Sep; 94(3):267-74. PubMed ID: 16126079
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of clasp retention forces and abrasion on different cast crowns.
    Jiang N; Gao WM; Zhang H; Zheng DX
    J Prosthet Dent; 2014 Jun; 111(6):493-8. PubMed ID: 24423460
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro investigation of the wear of resin composite materials and cast direct retainers during removable partial denture placement and removal.
    Tietge JD; Dixon DL; Breeding LC; Leary JM; Aquilino SA
    Int J Prosthodont; 1992; 5(2):145-53. PubMed ID: 1524635
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retentive forces and fatigue resistance of thermoplastic resin clasps.
    Tannous F; Steiner M; Shahin R; Kern M
    Dent Mater; 2012 Mar; 28(3):273-8. PubMed ID: 22130464
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.
    Cordaro L; Ercoli C; Rossini C; Torsello F; Feng C
    J Prosthet Dent; 2005 Oct; 94(4):313-20. PubMed ID: 16198167
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of clasp design on retention at different intervals using different abutment materials and in a simulated oral condition.
    Helal MA; Baraka OA; Sanad ME; Al-Khiary Y; Ludwig K; Kern M
    J Prosthodont; 2014 Feb; 23(2):140-5. PubMed ID: 23890209
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of transparent vinyl polysiloxane in a minimally invasive approach for creating composite resin undercuts for partial removable dental prostheses.
    Varjão FM
    J Prosthet Dent; 2012 Jan; 107(1):55-8. PubMed ID: 22230916
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study.
    Ortegón SM; Thompson GA; Agar JR; Taylor TD; Perdikis D
    J Prosthet Dent; 2009 Apr; 101(4):231-8. PubMed ID: 19328276
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the retentive force of a b-type Ti-6Mo-4Sn alloy wire clasp.
    Yoda N; Yokoyama M; Adachi G; Takahashi M; Sasaki K
    Int J Prosthodont; 2010; 23(1):38-41. PubMed ID: 20234890
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The abrasion of dental composite by cobalt-chromium clasps.
    Hamirudin MM; Barsby MJ
    Eur J Prosthodont Restor Dent; 2007 Mar; 15(1):13-8. PubMed ID: 17378453
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of box preparation on the strength of glass fiber-reinforced composite inlay-retained fixed partial dentures.
    Ozcan M; Breuklander MH; Vallittu PK
    J Prosthet Dent; 2005 Apr; 93(4):337-45. PubMed ID: 15798684
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Marginal adaptation of inlay-retained adhesive fixed partial dentures after mechanical and thermal stress: an in vitro study.
    Göehring TN; Peters OA; Lutz F
    J Prosthet Dent; 2001 Jul; 86(1):81-92. PubMed ID: 11458266
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of cast Ti-Ni alloy clasp retention with conventional removable partial denture clasps.
    Kim D; Park C; Yi Y; Cho L
    J Prosthet Dent; 2004 Apr; 91(4):374-82. PubMed ID: 15116040
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material.
    Hahnel S; Behr M; Handel G; Rosentritt M
    J Prosthet Dent; 2009 Apr; 101(4):269-78. PubMed ID: 19328280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation of composite retentive areas for removable partial denture retainers.
    Pavarina AC; Machado AL; Vergani CE; Giampaolo ET
    J Prosthet Dent; 2002 Aug; 88(2):218-20. PubMed ID: 12397251
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear of human enamel and nano-filled composite resin denture teeth under different loading forces.
    Ghazal M; Kern M
    J Oral Rehabil; 2009 Jan; 36(1):58-64. PubMed ID: 18976262
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP titanium in a cast framework association of removable partial overdenture.
    Souza JE; Silva NR; Coelho PG; Zavanelli AC; Ferracioli RC; Zavanelli RA
    J Contemp Dent Pract; 2011 May; 12(3):179-86. PubMed ID: 22186813
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthetic complications in mandibular metal-resin implant-fixed complete dental prostheses: a 5- to 9-year analysis.
    Purcell BA; McGlumphy EA; Holloway JA; Beck FM
    Int J Oral Maxillofac Implants; 2008; 23(5):847-57. PubMed ID: 19014154
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.