These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 20364824)

  • 1. Enhancement of molecular ions in mass spectrometry using an ultrashort optical pulse in multiphoton ionization.
    Shimizu T; Watanabe-Ezoe Y; Yamaguchi S; Tsukatani H; Imasaka T; Zaitsu S; Uchimura T; Imasaka T
    Anal Chem; 2010 May; 82(9):3441-4. PubMed ID: 20364824
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gas chromatography/time-of-flight mass spectrometry of triacetone triperoxide based on femtosecond laser ionization.
    Yamaguchi S; Uchimura T; Imasaka T; Imasaka T
    Rapid Commun Mass Spectrom; 2009 Oct; 23(19):3101-6. PubMed ID: 19705378
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of triacetone triperoxide using ultraviolet femtosecond multiphoton ionization time-of-flight mass spectrometry.
    Ezoe R; Imasaka T; Imasaka T
    Anal Chim Acta; 2015 Jan; 853():508-513. PubMed ID: 25467497
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interferometric characterization of ultrashort deep ultraviolet pulses using a multiphoton ionization mass spectrometer.
    Zaitsu S; Miyoshi Y; Kira F; Yamaguchi S; Uchimura T; Imasaka T
    Opt Lett; 2007 Jun; 32(12):1716-8. PubMed ID: 17572757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of triacetone triperoxide by gas chromatography/mass spectrometry and gas chromatography/tandem mass spectrometry by electron and chemical ionization.
    Sigman ME; Clark CD; Fidler R; Geiger CL; Clausen CA
    Rapid Commun Mass Spectrom; 2006; 20(19):2851-7. PubMed ID: 16941533
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical detection methods for mass spectrometry of macroions.
    Peng WP; Cai Y; Chang HC
    Mass Spectrom Rev; 2004; 23(6):443-65. PubMed ID: 15290710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resonant and nonresonant multiphoton ionization processes in the mass spectrometry of explosives.
    Hamachi A; Okuno T; Imasaka T; Kida Y; Imasaka T
    Anal Chem; 2015 Mar; 87(5):3027-31. PubMed ID: 25622138
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femtosecond laser-induced microstructures in glasses and applications in micro-optics.
    Qiu J
    Chem Rec; 2004; 4(1):50-8. PubMed ID: 15057868
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vacuum ultraviolet single photon versus femtosecond multiphoton ionization of sputtered germanium clusters.
    Wucher A; Heinrich R; Braun RM; Willey KF; Winograd N
    Rapid Commun Mass Spectrom; 1998; 12(18):1241-5. PubMed ID: 9772766
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Preparative linear ion trap mass spectrometer for separation and collection of purified proteins and peptides in arrays using ion soft landing.
    Blake TA; Ouyang Z; Wiseman JM; Takáts Z; Guymon AJ; Kothari S; Cooks RG
    Anal Chem; 2004 Nov; 76(21):6293-305. PubMed ID: 15516121
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of gas phase triacetone triperoxide with aspiration ion mobility spectrometry and gas chromatography-mass spectrometry.
    Räsänen RM; Nousiainen M; Peräkorpi K; Sillanpää M; Polari L; Anttalainen O; Utriainen M
    Anal Chim Acta; 2008 Aug; 623(1):59-65. PubMed ID: 18611458
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of triacetone triperoxide by ion mobility spectrometry and mass spectrometry following atmospheric pressure chemical ionization.
    Ewing RG; Waltman MJ; Atkinson DA
    Anal Chem; 2011 Jun; 83(12):4838-44. PubMed ID: 21524145
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Photon-trap spectroscopy of mass-selected ions in an ion trap: optical absorption and magneto-optical effects.
    Terasaki A; Majima T; Kondow T
    J Chem Phys; 2007 Dec; 127(23):231101. PubMed ID: 18154368
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Desorption/ionization fluence thresholds and improved mass spectral consistency measured using a flattop laser profile in the bioaerosol mass spectrometry of single Bacillus endospores.
    Steele PT; Srivastava A; Pitesky ME; Fergenson DP; Tobias HJ; Gard EE; Frank M
    Anal Chem; 2005 Nov; 77(22):7448-54. PubMed ID: 16285699
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gas-phase fluorescence excitation and emission spectroscopy of mass-selected trapped molecular ions.
    Bian Q; Forbes MW; Talbot FO; Jockusch RA
    Phys Chem Chem Phys; 2010 Mar; 12(11):2590-8. PubMed ID: 20200735
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultraviolet femtosecond laser ionization mass spectrometry.
    Imasaka T
    Chem Rec; 2008; 8(1):23-32. PubMed ID: 18302290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The efficiencies of resonant and nonresonant multiphoton ionization in the femtosecond region.
    Kouno H; Imasaka T
    Analyst; 2016 Sep; 141(18):5274-80. PubMed ID: 27326544
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of hydrophobic peptides by atmospheric pressure photoionization-mass spectrometry and tandem mass spectrometry.
    Delobel A; Halgand F; Laffranchise-Gosse B; Snijders H; Laprévote O
    Anal Chem; 2003 Nov; 75(21):5961-8. PubMed ID: 14588038
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Compatibility of electron ionization and soft ionization methods in gas chromatography/orthogonal time-of-flight mass spectrometry.
    Hejazi L; Ebrahimi D; Hibbert DB; Guilhaus M
    Rapid Commun Mass Spectrom; 2009 Jul; 23(14):2181-9. PubMed ID: 19530152
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Activation of large ions in FT-ICR mass spectrometry.
    Laskin J; Futrell JH
    Mass Spectrom Rev; 2005; 24(2):135-67. PubMed ID: 15389858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.