These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
541 related articles for article (PubMed ID: 20375779)
1. Motion changes in adjacent segments due to moderate and severe degeneration in C5-C6 disc: a poroelastic C3-T1 finite element model study. Hussain M; Natarajan RN; An HS; Andersson GB Spine (Phila Pa 1976); 2010 Apr; 35(9):939-47. PubMed ID: 20375779 [TBL] [Abstract][Full Text] [Related]
2. Posterior facet load changes in adjacent segments due to moderate and severe degeneration in C5-C6 disc: a poroelastic C3-T1 finite element model study. Hussain M; Natarajan RN; Chaudhary G; An HS; Andersson GB J Spinal Disord Tech; 2012 Jun; 25(4):218-25. PubMed ID: 22652989 [TBL] [Abstract][Full Text] [Related]
3. Progressive disc degeneration at C5-C6 segment affects the mechanics between disc heights and posterior facets above and below the degenerated segment: A flexion-extension investigation using a poroelastic C3-T1 finite element model. Hussain M; Natarajan RN; An HS; Andersson GB Med Eng Phys; 2012 Jun; 34(5):552-8. PubMed ID: 21925919 [TBL] [Abstract][Full Text] [Related]
4. Motion compensation associated with single-level cervical fusion: where does the lost motion go? Schwab JS; Diangelo DJ; Foley KT Spine (Phila Pa 1976); 2006 Oct; 31(21):2439-48. PubMed ID: 17023853 [TBL] [Abstract][Full Text] [Related]
5. Effect of two-level total disc replacement on cervical spine kinematics. Phillips FM; Tzermiadianos MN; Voronov LI; Havey RM; Carandang G; Dooris A; Patwardhan AG Spine (Phila Pa 1976); 2009 Oct; 34(22):E794-9. PubMed ID: 19829242 [TBL] [Abstract][Full Text] [Related]
6. Biomechanics of adjacent segments after a multilevel cervical corpectomy using anterior, posterior, and combined anterior-posterior instrumentation techniques: a finite element model study. Hussain M; Nassr A; Natarajan RN; An HS; Andersson GB Spine J; 2013 Jun; 13(6):689-96. PubMed ID: 23578989 [TBL] [Abstract][Full Text] [Related]
7. Reduction in segmental flexibility because of disc degeneration is accompanied by higher changes in facet loads than changes in disc pressure: a poroelastic C5-C6 finite element investigation. Hussain M; Natarajan RN; An HS; Andersson GB Spine J; 2010 Dec; 10(12):1069-77. PubMed ID: 21094468 [TBL] [Abstract][Full Text] [Related]
8. Cervical segmental motion at levels adjacent to disc herniation as determined with kinetic magnetic resonance imaging. Daffner SD; Xin J; Taghavi CE; Hymanson HJ; Mudiyam C; Hongyu W; Wang JC Spine (Phila Pa 1976); 2009 Oct; 34(22):2389-94. PubMed ID: 19829252 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of adjacent segmental motion after ventral cervical fixation with varying angles of lordosis. Hwang SH; Kayanja M; Milks RA; Benzel EC Spine J; 2007; 7(2):216-21. PubMed ID: 17321972 [TBL] [Abstract][Full Text] [Related]
10. Disc replacement adjacent to cervical fusion: a biomechanical comparison of hybrid construct versus two-level fusion. Lee MJ; Dumonski M; Phillips FM; Voronov LI; Renner SM; Carandang G; Havey RM; Patwardhan AG Spine (Phila Pa 1976); 2011 Nov; 36(23):1932-9. PubMed ID: 21289581 [TBL] [Abstract][Full Text] [Related]
11. Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study. Lin CY; Kang H; Rouleau JP; Hollister SJ; Marca FL Spine (Phila Pa 1976); 2009 Jul; 34(15):1554-60. PubMed ID: 19564765 [TBL] [Abstract][Full Text] [Related]
12. Using finite element analysis to determine effects of the motion loading method on facet joint forces after cervical disc degeneration. Cai XY; Sang D; Yuchi CX; Cui W; Zhang C; Du CF; Liu B Comput Biol Med; 2020 Jan; 116():103519. PubMed ID: 31710870 [TBL] [Abstract][Full Text] [Related]
13. Biomechanical effect of anterior cervical spine fusion on adjacent segments. Maiman DJ; Kumaresan S; Yoganandan N; Pintar FA Biomed Mater Eng; 1999; 9(1):27-38. PubMed ID: 10436851 [TBL] [Abstract][Full Text] [Related]
14. Kinematic analysis of the relationship between sagittal alignment and disc degeneration in the cervical spine. Miyazaki M; Hymanson HJ; Morishita Y; He W; Zhang H; Wu G; Kong MH; Tsumura H; Wang JC Spine (Phila Pa 1976); 2008 Nov; 33(23):E870-6. PubMed ID: 18978580 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical effect of C5-C6 intervertebral disc degeneration on the human lower cervical spine (C3-C7): a finite element study. Rahman WU; Jiang W; Zhao F; Li Z; Wang G; Yang G Comput Methods Biomech Biomed Engin; 2023 May; 26(7):820-834. PubMed ID: 35712878 [TBL] [Abstract][Full Text] [Related]
16. Use of the finite element method to study the mechanism of spinal cord injury without radiological abnormality in the cervical spine. Imajo Y; Hiiragi I; Kato Y; Taguchi T Spine (Phila Pa 1976); 2009 Jan; 34(2):E83-7. PubMed ID: 19139658 [TBL] [Abstract][Full Text] [Related]
17. Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematics. Cunningham BW; Hu N; Zorn CM; McAfee PC Spine J; 2010 Apr; 10(4):341-9. PubMed ID: 20362252 [TBL] [Abstract][Full Text] [Related]
18. Patterns of height changes in anterior and posterior cervical disc regions affects the contact loading at posterior facets during moderate and severe disc degeneration: a poroelastic C5-C6 finite element model study. Hussain M; Natarajan RN; An HS; Andersson GB Spine (Phila Pa 1976); 2010 Aug; 35(18):E873-81. PubMed ID: 21289493 [TBL] [Abstract][Full Text] [Related]
19. [Effects of novel angled cervical disc replacement on facet joint stress]. Bai C; Zhang W; Ling W; Tian Z; Dang X; Wang K Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Apr; 26(4):390-5. PubMed ID: 22568314 [TBL] [Abstract][Full Text] [Related]